Valid

GB/T 20255.6-2008Methods for chemical analysis of hard metals -- Flame atomic absorption spectrometry -- General requirements (English PDF)

硬质合金化学分析方法 火焰原子吸收光谱法 一般要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (3 pages)

Need quotation for your management?

Get a formal quotation for GB/T 20255.6-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

June 9, 2008

Implementation date

December 1, 2008

Scope

GB/T 20255.6-2008 is the English-translated version of 硬质合金化学分析方法 火焰原子吸收光谱法 一般要求.

GB/T 20255.6-2008 — This section provides general requirements for flame atomic absorption spectrometry Carbide chemical analysis. Each of the criteria listed in a part table defines the method for determining the content of the following elements by flame atomic absorption spectrometry.

Calcium, cobalt, chromium, iron, potassium, magnesium, manganese, molybdenum, sodium, nickel, titanium, vanadium.

Found what you need?

Document preview — GB/T 20255.6-2008

National Standard of the People's Republic of China

ICS
77.040.30
Classification
H 16

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Scope
  • 4 Interfering elements
  • 5 Reagents
  • 6 Instruments

Foreword

GB/T 20255 "Methods for chemical analysis Carbide" is divided into 6 sections.

GB/T 20255.1 Carbide chemical analysis of calcium, potassium, magnesium and sodium contents - Flame atomic absorption spectrometry;

GB/T 20255.2 Carbide chemical analysis of cobalt, iron, manganese and nickel content by flame atomic absorption spectrometry;

GB/T 20255.3 Carbide chemical analysis of molybdenum, titanium and vanadium content - Flame atomic absorption spectrometry;

Flame atomic GB/T 20255.4 Carbide chemical analysis of cobalt, iron, manganese, molybdenum, nickel, titanium and vanadium amount of light absorbed Spectroscopy;

Flame atomic GB/T 20255.5 amount of chromium carbide absorption spectrometry;

GB/T 20255.6 Carbide chemical analysis by flame atomic absorption spectrometry - General requirements.

Part is divided into 6 sections.

This part identical with ISO 7627/1. 1983 "--- Carbide Chemical analysis by flame atomic absorption spectrometry --- Part 1. a General requirements. " For ease of use, this section made the following editorial changes.

a) with "this Part" instead of "this International Standard";

"." B) use a decimal point instead of a decimal point in the international standard, "";

c) Remove the cover of the international standards, foreword.

This part is proposed by the China Nonferrous Metals Industry Association.

The non-ferrous metal part by the National Standardization Technical Committee.

This section Zhuzhou Cemented Carbide Group Co., Ltd., China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting.

1 Scope

This section provides general requirements for flame atomic absorption spectrometry Carbide chemical analysis.

Each of the criteria listed in a part table defines the method for determining the content of the following elements by flame atomic absorption spectrometry.

Calcium, cobalt, chromium, iron, potassium, magnesium, manganese, molybdenum, sodium, nickel, titanium, vanadium.

2 Scope

This method is applicable to the following ranges.

a) chromium, niobium, tantalum, titanium, tungsten, vanadium carbide;

b) a mixture of the carbide metal bonding;

c) Using the above-described various types of pre-sintered carbide production or sintered carbide;

d) after complete removal of the coating containing coated carbide elements listed in Table 1.

Table 1 GB/T 20255 and each element of each part number and scope of the appropriate section contains

No part of the respective range of elements (mass fraction) /% GB/T 20255.1 Ca, K, Mg, Na 0.001 ~ 0.02 GB/T 20255.2 Co, Fe, Mn, Ni 0.01 ~ 0.5 GB/T 20255.3 Mo, Ti, V 0.01 ~ 0.5 GB/T 20255.4 Co, Fe, Mn, Mo, Ni, Ti, V 0.5 ~ 2 GB/T 20255.5 Cr 0.01 ~ 2 Note. The method can also be used chromium content range (mass fraction) was measured at 0.01% to 2% of iron, nickel, cobalt and manganese.

Principle 3

Sample dissolution and flame atomic absorption spectrometry.

4 Interfering elements

Using a similar matrix in the test solution and standard solution to minimize the influence of interference.

5 Reagents

Use only analytical reagent and double distilled water or equivalent purity water analysis.

Note. The purity reagents required under certain circumstances.

6 Instruments

Conventional laboratory equipment and atomic absorption spectrometer.

NOTE. All the instrument parameters should be selected so that the best instrument sensitivity. Proposed that a single element hollow cathode lamp. See recommended equipment requirements GB/T 20255.1 - 20255.5 of the corresponding portion.

GB/T 20255.6-2008/ISO 7627/1. 1983

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 3 pages — is available in the English PDF.

How to Download GB/T 20255.6-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
3 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 20255.6-2008

$65.00