GB/T 19634-2021In vitro diagnostic test systems—General technical requirements for blood-glucose monitoring systems for self-testing (English PDF)

体外诊断检验系统 自测用血糖监测系统通用技术条件

Preview PDF

Also coversGBT19634-2021

This is a limited preview

Buy now to download the full PDF

Need quotation for your management?

Get a formal quotation for GB/T 19634-2021 in 30 minutes.

Issued by

State Administration for Market Regulation; Standardization Administration of China

Level / Type

National · Recommended

Issue date

October 11, 2021

Implementation date

May 1, 2023

Scope

GB/T 19634-2021 is the English-translated version of 体外诊断检验系统 自测用血糖监测系统通用技术条件.

GB/T 19634-2021 — This Standard specifies the terms and definitions, requirements, test methods, labels and instructions for use, packaging, transportation, and storage for blood-glucose monitoring systems for self-testing. This Standard is applicable to the blood-glucose monitoring systems for self-testing intended for in vitro monitoring the glucose concentration in capillary whole blood and/or venous whole blood (normally including portable glucose meters, disposable test strips, and control materials).

Found what you need?

Document preview — GB/T 19634-2021

National Standard of the People's Republic of China

ICS
11.100
Classification
C44

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • Foreword...3
  • Introduction...4
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and definitions...5
  • 4 Requirements...10
  • 5 Test method...11
  • 6 Labels and instructions for use...16
  • 7 Packaging, transportation, and storage...20
  • References...22
  • Attachment...24

Foreword

GB/T 19634 "In vitro diagnostic test systems - General technical requirements for

blood-glucose monitoring systems for self-testing" is not equivalent to ISO 15197.

This Standard was proposed by China Food and Drug Administration.

This Standard shall be under the jurisdiction of the National Clinical Trial Laboratory

and in-Vitro Diagnostic System Standardization Technical Committee.

Drafting organizations of this Standard. Beijing Institute of Medical Device Testing, and

American Johnson & Johnson Ltd.

Main drafters of this Standard. Hu Dongmei, Xu Yong, and John Mahoney.

Introduction

Blood-glucose monitoring systems for self-testing are in vitro diagnostic medical

devices used mainly by lay persons. When used properly, they can help diabetics to

monitor and take action to control the glucose concentration in the blood.

The primary objectives of this Standard are to establish requirements for the design of

blood-glucose monitoring systems that can result in acceptable results when used by

lay persons on the premises that users have accepted certain training, devices have

been properly maintained and operated according to the calibration and quality control

procedures in instructions for use of manufacturers, and to specify procedures for

verifying the conformance of blood-glucose monitoring systems' indicators to this

Standard.

This Standard illustrates general technical requirements for blood-glucose monitoring

systems for self-testing, including the information provided by the manufacturer and

labels and instructions of blood-glucose monitoring systems for self-testing. Since the

self-testing systems are used by lay persons, the information provided by the

manufacturer shall be explicit and easily to be understood, for the convenience of users

to have self-testing according to the operation procedures correctly. At the same time,

it shall provide certain warnings or prompts, to guide the appropriate measures under

abnormal results. This Standard specifies the information provided by the

manufacturer in detail.

In vitro diagnostic test systems - General technical

requirements for blood-glucose monitoring systems for

self-testing

1 Scope

This Standard specifies the terms and definitions, requirements, test methods, labels

and instructions for use, packaging, transportation, and storage for blood-glucose

monitoring systems for self-testing.

This Standard is applicable to the blood-glucose monitoring systems for self-testing

intended for in vitro monitoring the glucose concentration in capillary whole blood

and/or venous whole blood (normally including portable glucose meters, disposable

test strips, and control materials).

2 Normative references

The provisions in following documents become the provisions of this Standard through

reference in this Standard. For dated references, the subsequent amendments

(excluding corrigendum) or revisions do not apply to this Standard, however, parties

who reach an agreement based on this Standard are encouraged to study if the latest

versions of these documents are applicable. For undated references, the latest edition

of the referenced document applies.

GB 4793.1-1995 Safety requirements for electrical equipment for measurement,

control and laboratory use – Part 1.General requirements (idt IEC1010-1.1990)

GB 9706.1-1995 Medical electrical equipment – Part 1.General requirements for

safety (idt IEC 601-1.1988)

GB/T 14710-1993 Environmental requirements and testing methods for medical

electrical equipment

YY 0466-2003 Medical electrical equipment – Symbols for electrical equipment for

label, mark and providing information (ISO 15223.2000, IDT)

3 Terms and definitions

The following terms and definitions apply to this Standard.

[ISO 3534-1.1993, Definition 3.14]

Note 1.The precision degree is expressed in numerical form of the measurement imprecision obtained

by statistical measures, such as standard deviation (SD) and coefficient of variation (CV), that shows

a negative correlation with precision. Quantitative measures of precision depend on the specified

conditions.

Note 2.Precision of a given measurement procedure can be classified according to the clear precision

conditions. Precision under specific conditions are termed as "repeatability" and "reproducibility".

3.5

Repeatability

Consistency between test results obtained with continuous multiple measurements

under the same measurement conditions.

[JJF 1001-1998, Definition 5.6]

3.6

Repeatability conditions

Conditions where independent test results are obtained with the same test method, on

same test object, in the same laboratory, by the same operator, using the same

equipment, and within short intervals of time.

[ISO 3534-1.1993, Definition 3.16]

Note. Essentially constant conditions, intended to represent conditions resulting in test results of

minimum variability.

3.7

Blood-glucose meter

Component of a blood-glucose monitoring system, it can convert the result of a

chemical reaction into the glucose concentration in the sample.

3.8

Label

Printed, written or graphic information placed on a device or container.

3.9

Instructions for use

( > 75 mg/dL)

4.4 Batch-batch difference of blood-glucose test strips

Batch-batch difference between different batches of blood-glucose test strips shall not

be greater than 15%.

4.5 Control material

95% of test result obtained with control material shall be within the quality control range

of blood-glucose test strips.

4.6 Environmental test for blood-glucose meter

It shall meet the requirements of applicable articles in GB/T 14710-1993.

4.7 Safety requirements for blood-glucose meter

It shall meet the requirements of applicable articles in GB 9706.1-1995 and/or GB

4793.1-1995.

5 Test method

5.1 Test materials

a) Blood-glucose meter (at least 2 blood-glucose meters of the same specification

are recommended);

b) Blood-glucose test strips;

c) Reference analysis meter in accordance with manufacturer's suggestions;

d) Blood-glucose reference materials with traceability (such as the reference

material SRM 965 of National Institute of Standards and Technology (NIST));

e) Venous blood-sample or capillary blood-sample;

f) Blood collection tube added with proper anticoagulant;

g) Low speed centrifuge;

h) Straw;

i) Colorimetric tube or small test tube used for reference analysis meter;

j) Instructions for use of calibration and control procedures provided by the

manufacturer;

Note 1.In some cases, to promise the completion of measurement, a second skin puncture may be

necessary.

Note 2.It can adjust glucose concentrations in capillary blood-samples according to the method in

5.5.1a), to obtain samples in the lowest and highest concentration ranges.

5.4.2.2 Test procedure

DIVIDE capillary blood-sample into two aliquots firstly. PERFORM glucose

concentration test on one portion by reference analysis meter according to the

standard measurement procedure of manufacturer. TEST another portion by two

glucose meters according to the method in the instructions for use of manufacturer.

If reference analysis meter is only designed for testing plasma samples, then add an

anticoagulant recommended by the manufacturer into one portion, and collect plasma

by centrifugation at 1000g for 10 min. PERFORM the glucose measurement according

to the standard measurement procedure of manufacturer.

The differences between results of blood/plasma from each blood-glucose meter and

the results of blood/plasma from reference analysis meters are deemed as the

deviation.

5.5 Batch-batch difference of blood-glucose test strips

USE blood-glucose test strips of 2 different batches to repeatedly measure the fresh

anticoagulant venous blood or control material of normal fasting people for 10 times

respectively on a same blood-glucose meter. CALCULATE mean value of test results

of 2 batches respectively, and calculate the total mean value of test results of 3 batches.

CALCULATE batch-batch difference according t...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Download GB/T 19634-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19634-2021

$205.00