GB/T 19510.212-2023Controlgear for electric light sources - Part 2-12: Particular requirements for d. c. or a. c. supplied electronic ballasts for discharge lamps(excluding fluorescent lamps) (English PDF)
光源控制装置 第2-12部分:放电灯(荧光灯除外)用直流或交流电子镇流器的特殊要求
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19510.212-2023 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 28, 2023
Implementation date
January 1, 2026
Scope
GB/T 19510.212-2023 is the English-translated version of 光源控制装置 第2-12部分:放电灯(荧光灯除外)用直流或交流电子镇流器的特殊要求.
GB/T 19510.212-2023 — This document specifies the general requirements and safety requirements for DC or AC electronic ballasts: Power supply includes AC power 50Hz/Power supply below 60Hz and 1000V: This type of ballast is a converter equipped with triggering and stabilizing components that can operate at DC or the discharge lamp is operated at a frequency different from the mains frequency: Lamps matched with ballasts are specified in IEC 60188, IEC 60192, IEC 60662, it is specified in IEC 61167 and other general lighting source standards: This section does not include ballasts for fluorescent lamps and ballasts for theaters and motor vehicles Ballasts for special lamps:
Found what you need?
Document preview — GB/T 19510.212-2023
National Standard of the People's Republic of China
- ICS
- 29.140.99
- Classification
- K 74
- Replacing
- GB 19510.13-2007
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 General requirements
- 5 General requirements for testing
- 6 Category
- 7 Signs
- 8 Terminal
- 9 Protective grounding device
- 10 Protective measures against accidental contact with live parts
- 11 Moisture proof and insulation
- 12 Electrical strength
- 13 Heat resistance test of winding
- 14 Fault status
- 15 Protection measures for associated parts
- 16 Trigger voltage
- 17 Abnormal status
- 18 Structure
- 19 Creepage distances and clearances
- 20 Screws, current-carrying parts and connections
- 21 Resistant to heat, fire and marking
- 22 Corrosion resistance
- Appendix A (Normative) Tests to determine whether conductive parts are live parts that may cause electric shock
- Appendix B (Normative) Special Requirements for Thermal Protection Control Devices
- Appendix C (normative) Special requirements for light source electronic control devices with thermal protectors 10
- Appendix D (Normative) Heating test requirements for thermally protected control devices
- Appendix E (Normative) Application of constant S different from 4500 in tw (winding temperature) test
- Appendix F (Normative) Windshield
- Appendix G (normative) Derivation method of pulse voltage value
- Appendix H (Normative) Test
- Appendix I (Normative) Precautions to be observed when measuring with spherical arresters
- Reference
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents" Drafting:
This document is Part 2-12 of GB/T 19510 "Light Source Control Device": GB/T 19510 has published the following parts:
---Part 1: General requirements and safety requirements;
---Part 2-1: Special requirements for starting devices (except glow starters);
---Part 2-2: Special requirements for DC/AC electronic buck converters for tungsten lamps;
---Part 2-3: Special requirements for AC and/or DC electronic control devices for fluorescent lamps;
---Part 2-7: Special requirements for electronic control devices powered by safety service power supply (ESSS) for emergency lighting (self-contained);
---Part 2-8: Special requirements for ballasts for fluorescent lamps;
---Part 2-9: Special requirements for electromagnetic control devices for discharge lamps (except fluorescent lamps);
---Part 2-10: Special requirements for electronic inverters and frequency converters for high-frequency cold start tubular discharge lamps (neon lamps);
---Part 2-11: Special requirements for miscellaneous electronic circuits used with lamps;
---Part 2-12: Special requirements for DC or AC electronic ballasts for discharge lamps (except fluorescent lamps);
---Part 2-13: Special requirements for DC or AC electronic control devices for LED modules:
This document replaces GB 19510.13-2007 "Lamp control devices - Part 13: DC or AC for discharge lamps (except fluorescent lamps)" "Special Requirements for Electronic Ballasts", compared with GB 19510.13-2007, in addition to structural adjustments and editorial changes, the main technical changes as follows:
---Chapter 17 has been changed, and conditions c) have been added to control the ambient temperature of the device during the test, and the phases of resistor R2 and resistor R1 have been added:
Related content (see Chapter 17, Chapter 17 of GB 19510.13-2007):
This document is modified to adopt IEC 61347-2-12:2010 "Lamp control devices Part 2-12: DC for discharge lamps (except fluorescent lamps) or special requirements for AC electronic ballasts:
The technical differences between this document and IEC 61347-2-12:2010 and their reasons are as follows:
---Replaced IEC 60052 with normatively cited GB/T 311.6-2005 for ease of use;
---Replaced IEC 61347-1 with normatively cited GB/T 19510.1-2023 for ease of use:
The following editorial changes have been made to this document:
---In order to coordinate with the existing standards, the standard name is changed to "Light source control device Part 2-12: Discharge lamps (except fluorescent lamps) with direct Special requirements for current or AC electronic ballasts:
Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:
Introduction
With the development of light source control device technology, the safety specifications of the previous version of the light source control device can no longer be adapted to meet the current light source control requirements:
Technical requirements and product safety requirements of the device: Safety requirements ensure that electrical equipment is correctly installed, maintained and used in the manner intended Reduce harm to people, livestock or property: GB/T 19510 "Light Source Control Device" updates the technical and safety requirements to the regulations:
It is of great significance to standardize light source control devices, reduce product safety risks, improve product quality, and enhance the competitiveness of our products:
GB/T 19510 aims to standardize light source control devices and is intended to consist of the following parts:
---Part 1: General requirements and safety requirements: The purpose is to standardize the general requirements for control devices and their safety requirements:
---Part 2-1: Special requirements for starting devices (except glow starters): The purpose is to standardize starting devices (except glow starters) (external) special requirements for safety requirements:
---Part 2-2: Special requirements for DC/AC electronic step-down converters for tungsten lamps: The purpose is to standardize the direct use of tungsten filament lamps Special requirements for safety requirements of current/AC electronic buck converters:
---Part 2-3: Special requirements for AC and/or DC electronic control devices for fluorescent lamps: The purpose is to standardize AC for fluorescent lamps and/or special requirements for safety requirements of DC electronic control devices:
---Part 2-7: Special requirements for electronic control devices powered by safety service power supplies (ESSS) for emergency lighting (self-contained): Purpose Special requirements for regulating the safety requirements of electronic control devices powered by safety service power supplies (ESSS) for emergency lighting (self-contained):
---Part 2-8: Special requirements for ballasts for fluorescent lamps: The purpose is to standardize special safety requirements for ballasts for fluorescent lamps:
Require:
---Part 2-9: Special requirements for electromagnetic control devices for discharge lamps (except fluorescent lamps): The purpose is to standardize discharge lamps (fluorescent lamps Except) special requirements for safety requirements for electromagnetic control devices:
---Part 2-10: Special requirements for electronic inverters and frequency converters for high-frequency cold start tubular discharge lamps (neon lamps): The purpose is Special requirements for regulating the safety requirements of electronic inverters and frequency converters for high-frequency cold start tubular discharge lamps (neon lamps):
---Part 2-11: Special requirements for miscellaneous electronic circuits used with lamps: The purpose is to standardize miscellaneous electronics used in conjunction with lamps Special requirements for line safety requirements:
---Part 2-12: Special requirements for DC or AC electronic ballasts for discharge lamps (except fluorescent lamps): The purpose is to regulate discharge Special requirements for the safety of DC or AC electronic ballasts for lamps (other than fluorescent lamps):
---Part 2-13: Special requirements for DC or AC electronic control devices for LED modules: The purpose is to standardize the use of LED modules Special requirements for safety requirements for DC or AC electronic control devices:
This document is used together with GB/T 19510.1, which is revised after supplementing or modifying the corresponding provisions of GB/T 19510.1 made: This document and GB/T 19510.201~GB/T 19510.213 stipulate this when citing any clause of GB/T 19510.1:
The scope of application of the clauses and the test sequence of each test are specified, and necessary supplementary requirements are specified: Each part of GB/T 19510 is independent Established without reference to each other to facilitate future revisions and revisions: If deemed necessary, new requirements will be added:
Light source control devices Part 2-12:
Discharge lamps (except fluorescent lamps) use DC or AC Special requirements for electronic ballasts
1 Scope
This document specifies the general requirements and safety requirements for DC or AC electronic ballasts: Power supply includes AC power 50Hz/Power supply below 60Hz and 1000V: This type of ballast is a converter equipped with triggering and stabilizing components that can operate at DC or the discharge lamp is operated at a frequency different from the mains frequency: Lamps matched with ballasts are specified in IEC 60188, IEC 60192, IEC 60662, it is specified in IEC 61167 and other general lighting source standards: This section does not include ballasts for fluorescent lamps and ballasts for theaters and motor vehicles Ballasts for special lamps:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations for undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document:
GB/T 311.6-2005 Standard air gap for high voltage measurement (IEC 60052:2002, IDT) GB/T 19510.1-2023 Light source control device Part 1: General requirements and safety requirements (IEC 61347-1:2017, MOD)
3 Terms and definitions
The terms and definitions defined in GB/T 19510.1-2023 and the following apply to this document:
outputpoweroutputpower Predetermined average power value provided by the electronic ballast:
Output terminalsoutputterminals the terminal blocks on the ballast that are intended to be connected to the HID lamp:
Note: This terminal block is not a terminal block for intermediate transition between tungsten halogen lamps:
Trigger voltageignitionvoltage Up the maximum voltage developed between the output terminals:
Note 1: Basically, consists of the following types of pulses:
---Continuous effective value working voltage superimposed with non-sinusoidal single pulse;
---Continuous sinusoidal pulse voltage;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
How to Download GB/T 19510.212-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19510.1-2023 — Controlgear for electric light sources - Part 1: General and safety requirements
GB/T 19510.201-2023 — Controlgear for light sources - Part 2-1: Particular requirements for starting devices(other than glow starters)
GB/T 19510.202-2023 — Controlgear for electric light sources - Part 2-2: Particular requirements for d. c. or a. c. supplied electronic step-down convertors for filament lamps
Secure payment via Stripe
Payments accepted
GB/T 19510.212-2023
$360.00