Scope
GB/T 19495.9-2017 is the English-translated version of 转基因产品检测 植物产品液相芯片检测方法.
GB/T 19495.9-2017 is the part of the Chinese series on testing genetically modified products that describes liquid bead array detection for plant products.
It gives a qualitative method for the CaMV35S promoter and the NOS terminator, the two common screening elements, in maize, soybean, rapeseed, rice, cotton and other transgenic plants and their products.
In the method, fluorescence-encoded microspheres are coupled with oligonucleotide probes, bound to the target and to a fluorescent reporter, and read in a flow system where a red laser identifies each microsphere and a green laser measures the bound reporter.
It lists the abbreviations PCR, MFI and SA-PE and relies on GB/T 6682 for laboratory water and on other parts of GB/T 19495 for sampling and nucleic acid extraction. It was issued on 29 December 2017 and has applied since 1 July 2018.
Found what you need?
Document preview — GB/T 19495.9-2017
National Standard of the People's Republic of China
- ICS
- 07.080
- Classification
- A 40
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Abbreviations
- 4 Principle
Foreword
GB/T 19495 "Genetically Modified Products Testing" has released or plans to release the following sections.
--- GB/T 19495.1 Genetically Modified Products Testing General Requirements and Definitions;
--- GB/T 19495.2 Genetically Modified Products Testing Laboratory technical requirements;
--- GB/T 19495.3 GMO product detection nucleic acid extraction and purification methods;
--- GB/T 19495.4 GMO products detection of nucleic acid qualitative PCR detection method;
--- GB/T 19495.5 GMO products for detection of nucleic acid quantitative PCR detection method;
--- GB/T 19495.6 Genetically Modified Products Detection of gene chip detection methods;
--- GB/T 19495.7 Genetically Modified Products Sampling and sample preparation methods;
--- GB/T 19495.8 Genetically Modified Products for Detection of Protein Detection Methods;
--- GB/T 19495.9 Genetically Modified Products Testing of plant products liquid chip detection methods;
--- GB/T 19495.10 Genetically Modified Products General Test Method for Plant Products;
--- GB/T 19495.11 Genetically Modified Products Testing of plant products digital PCR detection method;
--- GB/T 19495.12 GMO detection of alfalfa real-time fluorescent PCR detection method.
This section is GB/T 19495 9 parts.
This section drafted in accordance with GB/T 1.1-2009 given rules.
1 Scope
GB 19495 provisions of this part of the qualitative detection of liquid components of the genetically modified chips.
This section applies to corn, soybeans, rapeseed, rice, cotton and other transgenic plants and their products CaMV35S and NOS gene qualitative Detection.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 6682 analytical laboratory water specifications and test methods
GB/T 19495.1 Genetically Modified Products General Requirements and Definitions
GB/T 19495.3 Genetically modified products for nucleic acid extraction and purification methods
GB/T 19495.7 Genetically Modified Products - Sampling and Sample Preparation Methods
3 Abbreviations
The following abbreviations apply to this document.
PCR. Polymerase Chain Reaction (Polymerase Chain Reaction)
MFI. Median Fluorescence Intensity
SA-PE. Streptavidin-Phycoerythrin
4 Principle
Liquid-chip technology to fluorescent-encoded microspheres based microspheres with a large number of active surface groups, with nucleic acid probes, antigens, antibodies, etc. Molecular coupling. Microspheres in the preparation process incorporates two kinds of red and orange dyes in proportion to mix the fluorescent dye, two kinds of dye points Different proportions are given to the microspheres of different colors, which microspheres are divided into many kinds, each microsphere-specific coupling for the purpose of DNA Sequence of oligonucleotide probes, it is possible to label 100 different probe molecules. Then add the target molecules and fluorescence with the report Molecules, probe molecules on different microspheres and different molecules to achieve specific binding, the formation of a flexible liquid-chip system. This The method for signal recognition and detection is flow cytometry, which rapidly arranges microspheres in single columns through the detection channel using red and green The two laser beams illuminate the individual microspheres. The red laser classifies the microspheres by identifying the spectral fingerprint of the microspheres themselves The green laser detects the molecular weight of the bound fluorescent reporter on the microspheres to quantify the reaction. The resulting fluorescence signal is photoimaged After the tube by the computer processing, the final analysis of the data, the results. When testing, liquid-phase chip detector records only two kinds of fluorescence at the same time Current fluorescent signals do not record unbound fluorescent reporter signals.
This standard for universal screening element CaMV35S promoter and NOS terminator designed to select specific primers and probes for liquid phase Chip detection, and based on test results to determine the CaMV35S promoter and NOS terminator exogenous screening element components.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 19495.1Detection of genetically modified organisms and derived products--General requirements and definitions
- GB/T 19495.3Detection of genetically modified organisms and derived products--Nucleic acid extraction
- GB/T 19495.7Detection of genetically modified organisms and derived products--Methods for sampling and sample preparation
Similar standards
How to Download GB/T 19495.9-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19495.1-2004 — Detection of genetically modified organisms and derived products--General requirements and definitions
GB/T 19495.3-2004 — Detection of genetically modified organisms and derived products--Nucleic acid extraction
GB/T 19495.7-2004 — Detection of genetically modified organisms and derived products--Methods for sampling and sample preparation
Secure payment via Stripe
Payments accepted
GB/T 19495.9-2017
$85.00