Valid

GB/T 19216.31-2008Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 31: Procedures and requirements for fire with shock -- Cables of rated voltage up to and including 0.6/1 kV (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GB/T 19216.31-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

December 31, 2008

Implementation date

November 1, 2009

Scope

GB/T 19216.31-2008 (Tests for electric or optical fibre cables under fire conditions -- Circuit integrity -- Part 31: Procedures and requirements for fire with shock -- Cables of rated voltage up to and including 0.6/1 kV) is available as an English-translated PDF.

GB/T 19216.31-2008 — This section GB/T 19216 specifies the rated voltage 0.6/1kV and below the need to maintain the integrity of the cable lines in specific conditions Fire and mechanical shock test procedures and performance requirements, and provides time for the fire.

This section is intended for diameter greater than 20mm test cable. This section provides sample preparation, continuity checking devices, electrical test procedures, methods of burning cables and mechanical shock generated Method, and provides the results of the assessment requirements.

This section applies to low-voltage power cables and control cables with a rated voltage. NOTE.

Although this section is limited to the scope of application of rated voltage 0.6/1kV and below the cables, but the manufacturer and the purchaser agrees, and is equipped with the appropriate fuse After the device, the procedure can also be used below the rated voltage of 3.3kV and cables.

Found what you need?

Document preview — GB/T 19216.31-2008

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13

Issued by: Standardization Administration of China

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Sample
  • 5 Continuity test unit
  • 6 Test Procedure
  • 7 Performance Requirements
  • 8 Repeat the test procedure
  • 9 Test report

Foreword

GB/T 19216 "in electric cables under fire conditions - Circuit integrity" is divided into six sections.

--- Part 11. Test equipment --- flame temperature not lower than 750 °C \u200b\u200bseparately for the fire;

Applying an impact test apparatus --- flame temperature of not lower than 830 °C for fights;. --- Part 12

--- Part 21. Procedures and requirements --- rated voltage 0.6/1.0kV and below cable;

--- Part 23. Procedures and requirements --- data cable;

--- Part 25. Procedures and requirements --- fiber optic cable;

--- Part 31. for fire with shock - Test procedure and requirements --- rated voltage 0.6/1kV and below cable.

This section GB/T 19216 of Part 31.

This section identical with IEC 60331-31:2002 "cables under fire conditions - Circuit integrity - Part 31. applying for fights Plus the impact of the test procedures and requirements --- rated voltage 0.6/1kV and below cable "(in English).

For ease of use, this section made the following editorial changes.

--- This part name is amended as. "In the electric cables under fire conditions - Circuit integrity - Part 31. impulse applied for fights Hit test procedures and requirements --- rated voltage 0.6/1kV and below cable ";

--- This part corresponds to the name, the English name changed to. "Testsforelectricoropticalfibrecablesunderfire conditions-Circuitintegrity-Part 31. Proceduresandrequirementsforfirewithshock-Cables ofratedvoltageuptoandincluding0.6/1kV ";

--- Remove the IEC 60331-31:2002 Foreword and Introduction;

--- With a decimal point "." Instead of a comma as the decimal point "." this part is proposed by the China Electrical Equipment Industrial Association.

This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized.

This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.

Participated in the drafting of this section. Sichuan Star Cable Co., Ltd., Shanghai Shenghua Cable (Group) Co., Ltd. Jinlong Yu Group Limited Secretary of Jiangsu New Remote Cable Co., Ltd., Shanghai-Wuxi City Wire and Cable Co., Ltd. Wuxi Jiangnan Cable.

1 Scope

This section GB/T 19216 specifies the rated voltage 0.6/1kV and below the need to maintain the integrity of the cable lines in specific conditions Fire and mechanical shock test procedures and performance requirements, and provides time for the fire. This section is intended for diameter greater than 20mm test cable.

This section provides sample preparation, continuity checking devices, electrical test procedures, methods of burning cables and mechanical shock generated Method, and provides the results of the assessment requirements.

This section applies to low-voltage power cables and control cables with a rated voltage.

NOTE. Although this section is limited to the scope of application of rated voltage 0.6/1kV and below the cables, but the manufacturer and the purchaser agrees, and is equipped with the appropriate fuse After the device, the procedure can also be used below the rated voltage of 3.3kV and cables.

2 Normative references

The following documents contain provisions which, through reference GB/T 19216 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 13539.5-1999 Low-voltage fuses - Part 3. unskilled personnel Supplementary requirements for fuses (mainly used Fuses for household and similar applications) - Examples of standardized fuses (idt IEC 60269-3-1:1994) GB/T 19216.12-2008 in electric cables under fire conditions - Circuit integrity - Part 12. Apparatus ---Applying an impact flame temperature not lower than 830 °C for the fights (IEC 60331-12:2002, IDT) GB/T 19216.21-2003 in Part 21 Circuit integrity under fire conditions - cable or fiber optic cable. To test procedure and Seeking --- rated voltage 0.6/1.0kV and below cables (IEC 60331-21:1999, IDT) 1997 application development and basic safety publications, safety publications and similar security publications. IEC Guide 104

3 Terms and Definitions

The following terms and definitions apply to this section.

When under fire and prescribed burning time, it can continue to run in the state the ability to specify.

4 Sample

4.1 Sample Preparation

Take a length of not less than 1500mm finished cable as a sample, and at each end of the cable sheath or strip about the outer 100mm Sheath.

At each end of the cable, should properly handle each conductor for electrical connection, and should be separated from each other to avoid the exposed conductor GB/T 19216.31-2008/IEC 60331-31:2002

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 19216.31-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19216.31-2008