GB/T 19216.2-2021Circuit integrity test for electric cables or optical fiber cables under fire conditions - Part 2: Test method for fire with shock at a temperature of at least 830 degrees C for cables of rated voltage up to and including 0.6/1 kV and with an overall diameter exceeding 20 mm (English PDF)
在火焰条件下电缆或光缆的线路完整性试验 第2部分:火焰温度不低于830 ℃的供火并施加冲击振动,额定电压0.6/1 kV及以下外径不超过20 mm电缆的试验方法
This is a limited preview
Buy now to download the full PDF (37 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19216.2-2021 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
May 21, 2021
Implementation date
December 1, 2021
Scope
GB/T 19216.2-2021 is the English-translated version of 在火焰条件下电缆或光缆的线路完整性试验 第2部分:火焰温度不低于830 ℃的供火并施加冲击振动,额定电压0.6/1 kV及以下外径不超过20 mm电缆的试验方法.
GB/T 19216.2-2021 is the Chinese standard "Circuit integrity test for electric cables or optical fiber cables under fire conditions - Part 2: Test method for fire with shock at a temperature of at least 830 degrees C for cables of rated voltage up to and including 0.6/1 kV and with an overall diameter exceeding 20 mm".
Its scope clause reads: This document describes the test methods for maintaining the integrity of the circuit when fire-resistant cables are subjected to flame and shock vibration under specified conditions.
This document applies to cables with a rated voltage of 0.6/1kV and below, including metal conductor data and telecommunications with a rated voltage below 80V Electric cables and optical cables.
This document applies to test cables with an outer diameter less than or equal to 20mm. Cables with larger diameters will be tested using the equipment, procedures and requirements of GB/T 19216.1.
This document describes the test failure points, continuity check devices, and test points of power cables and control cables with a rated voltage of 0.6/1kV and below.
Detailed information of the test samples, test procedures and test reports. The metal conductor data and the test failure point and continuity of telecommunications cables and optical cables are not given.
Detailed information about the test equipment, test samples, test procedures and test reports.
Although the scope of application is limited to cables with a rated voltage of 0.6/1kV and below, when the manufacturer and the buyer agree, and are equipped with suitable After the fuse, it can also be applied to cables with a rated voltage of 1.8/3(3.3)kV and below.
Appendix A gives the verification method of the burner and control system used in the test. When you need to identify the mark, you can choose to mark on the cable to indicate compliance with this document.
Caution. The tests in this document may involve the use of dangerous voltages and temperatures. Appropriate precautions should be taken to prevent possible Risks of electric shock, burning, fire and explosion, as well as any harmful gases that may be produced. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 19216.2-2021
National Standard of the People's Republic of China
- Classification
- K 13
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Test environment
- 5 Test equipment
- 6 Sample (power cable and control cable with rated voltage 0.6/1kV and below)
- 7 Test procedure (power cable and control cable with rated voltage 0.6/1kV and below)
- 8 Performance requirements (power cables and control cables with rated voltage 0.6/1kV and below)
- 9 Repeat test procedure
- 10 Test report (power cable and control cable with rated voltage 0.6/1kV and below)
- 11 Cable mark
- Appendix A (Normative) Verification Procedure for Heat Source
1 Scope
This document describes the test methods for maintaining the integrity of the circuit when fire-resistant cables are subjected to flame and shock vibration under specified conditions.
This document applies to cables with a rated voltage of 0.6/1kV and below, including metal conductor data and telecommunications with a rated voltage below 80V
Electric cables and optical cables.
This document applies to test cables with an outer diameter less than or equal to 20mm.
Cables with larger diameters will be tested using the equipment, procedures and requirements of GB/T 19216.1.
This document describes the test failure points, continuity check devices, and test points of power cables and control cables with a rated voltage of 0.6/1kV and below.
Detailed information of the test samples, test procedures and test reports. The metal conductor data and the test failure point and continuity of telecommunications cables and optical cables are not given.
Detailed information about the test equipment, test samples, test procedures and test reports.
Although the scope of application is limited to cables with a rated voltage of 0.6/1kV and below, when the manufacturer and the buyer agree, and are equipped with suitable
After the fuse, it can also be applied to cables with a rated voltage of 1.8/3(3.3)kV and below.
Appendix A gives the verification method of the burner and control system used in the test.
When you need to identify the mark, you can choose to mark on the cable to indicate compliance with this document.
Caution. The tests in this document may involve the use of dangerous voltages and temperatures. Appropriate precautions should be taken to prevent possible
Risks of electric shock, burning, fire and explosion, as well as any harmful gases that may be produced.
2 Normative references
The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations
Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
This document.
IEC 60269-3 Low-voltage fuses Part 3.Supplementary requirements for fuses used by unskilled personnel (mainly used for household and class
Similar purpose fuses) Examples of standardized fuse systems A to F (Low-voltagefuses-Part 3.Supplementaryre-
Requirementsforfusesforusebyunskiledpersons(fusesmainlyforhouseholdandsimilarapplica- tions)-ExamplesofstandardizedsystemsoffusesAtoF]
IEC 60584-1 Thermocouple Part 1.Thermoelectromotive force specifications and tolerances (Thermocouples-Part 1.EMFspecifica- tionsandtolerances)
3 Terms and definitions
The following terms and definitions apply to this document.
GB/T 19666 | GB/T 18890.1 | GB/T 18890.2 | GB/T 13849 | GB/T 13029.1 | GB/T 19216.3 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 37 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60269 · IEC 60584
How to Download GB/T 19216.2-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19216.3-2021 — Circuit integrity test for electric cables or optical fiber cables under fire conditions - Part 3: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0.6/1 kV tested in a metal enclosure
GB/T 19216.1-2021 — Circuit integrity test for electric cables or optical fiber cables under fire conditions - Part 1: Test method for fire with shock at atemperature of at least 830 °C for cables of rated voltage up to and including 0.6/ 1 kV and with an overall diameter exceeding 20 mm
GB/T 19216.11-2003 — Tests for electric cables under fire conditions -- Circuit integrity -- Part 11: Apparatus -- Fire alone at a flame temperature of at least 750 Celsius
Secure payment via Stripe
Payments accepted
GB/T 19216.2-2021
$385.00