Valid

GB/T 18216.10-2022Electrical safety in low voltage distribution systems up to 1000V a.c. and 1500V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring or monitoring of protective measur (English PDF)

Also coversGBT18216.10-2022

Open the GB/T 18216.10-2022 preview as PDF

Preview — first pages of GB/T 18216.10-2022

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

October 12, 2022

Implementation date

May 1, 2023

Scope

GB/T 18216.10-2022 (Electrical safety in low voltage distribution systems up to 1000V a.c. and 1500V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 10: Combined measuring equipment for testing, measuring or monitoring of protective measur) is available as an English-translated PDF.

GB/T 18216.10-2022 — This document specifies the combination within one device of several measuring functions or functions for testing, measuring or monitoring in accordance with the various parts of IEC 61557. Requirements for combined measuring equipment for test methods.

Document preview — GB/T 18216.10-2022

National Standard of the People's Republic of China

Classification
N 20

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • foreword
  • Introduction
  • 1 Scope
  • 2 Normative references

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"

drafted.

This document is GB/T 18216 "AC 1000V and DC 1500V and below low-voltage power distribution system electrical safety protection measures.

Test, Measuring or Monitoring Equipment, Part 10.GB/T 18216 has published the following parts.

--- Part 1.General requirements;

--- Part 2.Insulation resistance;

--- Part 3.Loop impedance;

--- Part 4.Grounding resistance and equipotential grounding resistance;

--- Part 5.Resistance to ground;

--- Part 6.Effectiveness of residual current devices (RCDs) in TT, TN and IT systems;

--- Part 8.Insulation monitoring devices in IT systems;

--- Part 9.Equipment for locating insulation faults in IT systems;

--- Part 10.Combined measuring equipment for testing, measuring or monitoring protective measures;

--- Part 12.Performance measurement and monitoring device (PMD).

This document is identical to IEC 61557-10.2013 "Electrical safety of low-voltage power distribution systems of AC 1000V and DC 1500V and below"

Testing, measuring or monitoring equipment for total protective measures - Part 10.Combined measuring equipment for testing, measuring or monitoring of protective measures

Prepare".

Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents.

Introduction

IEC 60364-6 specifies the initial testing, continuous monitoring and adjustment of electrical installations in TN, TT or IT systems.

Standardized conditions for post-conditioning experiments. In addition to specifying general standards for carrying out these tests, IEC 60364-6 also covers the need to pass measurements

to verify the requirements. Only in a few cases, such as when measuring insulation resistance, does IEC 60364-6 cover the measuring equipment used.

set feature details. Circuit diagrams given as examples in IEC 60364-6 and referenced in the text of the document are generally not applicable to

actual use.

Conducting tests in electrical installations can easily lead to accidental

outside. Therefore, in addition to simplifying the measurement, technicians need to rely on the measurement device to ensure the safety of the measurement method.

The application of the general safety rules for electrical and electronic measuring devices (IEC 61010-1) for testing of protective measures is not sufficient in itself. exist

Measurements in electrical installations are not only harmful to technicians, but also to third parties due to different measurement methods.

Also, in order to obtain an objective judgement about the equipment, for example periodic testing after equipment handover, continuous insulation monitoring or

In the case of performance assurance, an important prerequisite is to obtain reliable and comparable measurement results using measuring devices from different manufacturers.

The purpose of formulating GB/T 18216 is to specify uniform principles consistent with the above characteristics, these principles apply to nominal voltage AC

Measuring and monitoring equipment for electrical safety testing and performance testing in systems of 1000V and DC 1500V and below. GB/T 18216

It consists of ten parts.

--- Part 1.General requirements. The purpose is to establish a low-voltage power distribution system with a nominal voltage of AC 1000V and DC 1500V and below.

General requirements for test equipment used in electrical safety measurement and monitoring systems.

--- Part 2.Insulation resistance. The purpose is to establish that the measurement is suitable for the insulation of equipment and electrical installations in the non-excited state

Requirements for resistive devices.

--- Part 3.Loop impedance. The purpose is to establish between the measuring line conductor and the protective conductor, between the line conductor and the neutral conductor or between the two conductors.

Requirements related to loop impedance equipment between line conductors.

--- Part 4.Grounding resistance and equipotential grounding resistance. The purpose is to establish the grounding conductor, protective grounding conductor and

and related technical requirements for the resistance of equipotential bonding conductors.

--- Part 5.Resistance to ground. The purpose is to establish the requirements for measuring equipment that uses AC voltage to measure resistance to earth.

--- Part 6.Effectiveness of residual current devices (RCDs) in TT, TN and IT systems. The purpose is to establish a test for TT,

Requirements for measuring equipment for the effectiveness of protective measures for residual current devices in TN and IT systems.

--- Part 8.Insulation monitoring devices in IT systems. The purpose is to establish the relevant requirements for insulation monitoring devices in IT systems.

--- Part 9.Insulation fault location equipment in IT systems. The purpose is to establish the phase of insulation fault location equipment in IT system.

off requirements.

--- Part 10.Combined measuring equipment for testing, measuring or monitoring protective measures. The purpose is to establish within a device

A combined measuring device that combines several measuring functions or test methods for testing, measuring or monitoring in accordance with the various parts of IEC 61557

prepared requirements.

--- Part 12.Performance measurement and monitoring device (PMD). The purpose is to establish a comprehensive system for measuring and monitoring electrical parameters in power distribution systems.

meet the relevant requirements for performance measurement and monitoring devices.

AC 1000V and DC 1500V and below low voltage

Test of electrical safety protection measures for power distribution system,

Measuring or monitoring equipment - Part 10.For protection

Combined measuring equipment for testing, measuring or monitoring measures

1 Scope

This document specifies the combination within one device of several measuring functions or functions for testing, measuring or monitoring in accordance with the various parts of IEC 61557.

Requirements for combined measuring equipment for test methods.

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations

documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to

this document.

IEC 61010-2-030.2017 Safety requirements for electrical equipment for measurement, control and laboratory use Part 2-030.Test or measurement

circuits)1)

IEC 61557-1 Test and measurement of electrical safety protection measures for low-voltage power distribution systems of AC 1000V and DC 1500V and below

measures-Part 1.Generalrequirements)

Note 1.GB/T 18216.1-2021 Test and measurement of electrical safety protection measures for AC 1000V and DC 1500V and below low-voltage power distribution systems

Or monitoring equipment Part 1.General requirements (IEC 61557-1.2019, IDT).

IEC 61557-2 Test and measurement of electrical safety protection measures for low-voltage power distribution systems of AC 1000V and DC 1500V and below

Note 2.GB/T 18216.2-2021 Test and measurement of electrical safety protection measures for AC 1000V and DC 1500V and below low-voltage power distribution systems

Or monitoring equipment Part 2.Insulation resistance (IEC 61557-2.2019, IDT).

IEC 61557-3 Test and measurement of electrical safety protection measures for low-voltage power distribution systems of AC 1000V and DC 1500V and below

measures-Part 3.Loopimpedance)

Note 3.GB/T 18216.3-2021 Test and measurement of electrical safety protection measures for AC 1000V and DC 1500V and below low-voltage power distribution systems

Or monitoring equipment Part 3.Loop impedance (IEC 61557-3.2019, IDT).

1) The original text is IEC 61010-2-030.2010, which has been abolished. The latest version is IEC 61010-2-030.2017, and the related technical content cited has not changed.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

IEC 61010 · IEC 61557 · GB/T 18216.1-2021 · GB/T 18216.2-2021 · GB/T 18216.3-2021

How to Buy GB/T 18216.10-2022

  1. 1Add to cart. Click the "Buy GB/T 18216.10-2022" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18216.10-2022

$155.00

$130.00for partners