GB/T 17737.106-2018Coaxial communication cables -- Part 1-106: Electrical test methods -- Test for withstand voltage of cable sheath (English PDF)
Also coversGBT17737.106-2018
Open the GB/T 17737.106-2018 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
March 15, 2018
Implementation date
October 1, 2018
Scope
GB/T 17737.106-2018 (Coaxial communication cables -- Part 1-106: Electrical test methods -- Test for withstand voltage of cable sheath) is available as an English-translated PDF.
GB/T 17737.106-2018 — This part of GB/T 17737 applies to coaxial communication cables. It specifies the test method for determining the withstand voltage of a coaxial cable sheath.
Document preview — GB/T 17737.106-2018
National Standard of the People's Republic of China
- ICS
- 33.120.10
- Classification
- L 26
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Cable sheath withstand voltage test
- 4.1 Principle
- 4.2 Test Equipment
- 4.3 sample preparation
- 4.4 Procedures
Foreword
GB/T 17737 "Coaxial Communication Cable" has or plans to issue the following parts.
--- Part 1. General rules, definitions and requirements;
--- Part 1-100. General requirements for electrical test methods;
--- Part 1-101 . Electrical test methods Conductor direct current resistance test ;
--- Part 1-102 . Electrical test methods ; Insulation resistance test of dielectrics for cables ;
--- Part 1-103 . Electrical test methods Capacitance test of cables ;
--- Part 1-104 . Electrical test methods ; Capacitance stability test of cables ;
--- Part 1-105. Electrical test methods for withstand voltage test of cable dielectrics;
--- Part 1-101 . Electrical test methods Voltage withstand test of cable sheathing ;
--- Part 1-107 . Electrical test methods Vibrating cable charge level (mechanically induced noise) test;
--- Part 1-108. Electrical test methods Characteristic impedance, phase delay, group delay, electrical length and propagation speed test;
--- Part 1-110 . Electrical test method continuity ;
--- Part 1-111 . Electrical test methods Stability test for phase constants ;
--- Part 1-112. Electrical test methods Return Loss (Impedance Consistency) test;
--- Part 1-113 . Electrical test method attenuation constant test ;
--- Part 1-114 . Electrical test methods Inductors ;
--- Part 1-115. Electrical test method impedance uniformity (pulse/step function return loss) test;
--- Part 1-116 . Electrical test methods TDR method measuring characteristic impedance ;
--- Part 1-119 . Electrical test methods RF power rating ;
--- Part 1-122. Electrical test methods - Cross-talk test between coaxial cables;
This part is part 1-106 of GB/T 17737.
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the translation method identical to the use of IEC 61196-1-106.2008 "coaxial communication cable Part 1-106. Electrical test method
Cable jacket withstand voltage test".
The Chinese documents that have a consistent correspondence with the normatively quoted international documents in this section are as follows.
---GB/T 17737.1-2013 Coaxial telecommunication cables Part 1. General specifications General, definitions and requirements (IEC 61196-1.
2005, IDT).
1 Scope
This part of GB/T 17737 applies to coaxial communication cables. It specifies the test method for determining the withstand voltage of a coaxial cable sheath.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
IEC 61196-1 Coaxial Communication Cables Part 1. Generic Specification General, Definitions and Requirements (Coaxialcommunicationca-
bles-Part 1.Generic specification-General,definitionsandrequirements)
3 Terms and definitions
The terms and definitions defined by IEC 61196-1 apply to this document.
4 Cable sheath withstand voltage test
4.1 Principle
This test measures the withstand voltage of the sheath by immersion in water.
4.2 Test Equipment
A metal water tank with a suitable electrode and an AC power supply with a frequency of 40 Hz to 60 Hz, with a voltage RMS adjustment range of 0.8 kV~
5kV.
4.3 sample preparation
A sufficient length of cable shall be taken from the finished cable as specified in the relevant sub-standard or detailed specification, and the sheath shall be stripped off at one end of the cable so that
Shield and power connection.
4.4 Procedures
Dip the cable into water at a temperature of 15°C to 35°C for 1 hour. Both ends of the cable are exposed to sufficient length to prevent voltage breakdown. When soaking
At the end of the interval, the AC test voltage specified in the table below (unless otherwise specified) shall be applied between the outer conductor or the shield and the water for not less than 1 min.
It does not exceed 2 minutes.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61196
How to Buy GB/T 17737.106-2018
- 1Add to cart. Click the "Buy GB/T 17737.106-2018" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17737.100-2018 — Coaxial communication cables -- Part 1-100: Electrical test methods -- General requirements
GB/T 17737.101-2018 — Coaxial communication cables -- Part 1-101: Electrical test methods -- Test for conductor d.c. resistance of cable
GB/T 17737.102-2018 — Coaxial communication cables -- Part 1-102: Electrical test methods -- Test for insulation resistance of cable dielectric
Secure payment via Stripe
Payments accepted
GB/T 17737.106-2018
$70.00