Valid

GB/T 17213.8-2015Industrial-process control valves -- Part 8-1: Noise considerations -- Laboratory measurement of noise generated by aerodynamic flow through control valves (English PDF)

工业过程控制阀 第8-1部分:噪声的考虑 实验室内测量空气动力流流经控制阀产生的噪声

Preview PDF

This is a limited preview

Buy now to download the full PDF (16 pages)

Need quotation for your management?

Get a formal quotation for GB/T 17213.8-2015 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Level / Type

National · Recommended

Issue date

December 10, 2015

Implementation date

July 1, 2016

Scope

GB/T 17213.8-2015 is the English-translated version of 工业过程控制阀 第8-1部分:噪声的考虑 实验室内测量空气动力流流经控制阀产生的噪声.

GB/T 17213.8-2015 is the Chinese standard "Industrial-process control valves -- Part 8-1: Noise considerations -- Laboratory measurement of noise generated by aerodynamic flow through control valves".

Its scope clause reads: This Part of GB/T 17213 defines equipment, methods, and procedures for obtaining laboratory measurements of sound pressure levels radiated by control valves and/or associated piping configurations, including fixed restrictions, through which compressible fluids are passing.

Control valves discharging to atmosphere are excluded from this Part. Method A is a uniform method of measuring the radiated noise from the valve and associated test piping and allows a comparison of various measuring results which is beneficial for both user and manufacturer.

The noise criteria are expressed by determining the sound pressure level of the valve under consideration. Method B is a procedure for measuring the sound pressure levels within pipe systems upstream and downstream of the valve under fixed operating conditions.

Since inaccuracies due to the pipe transmission are eliminated, this method is preferred for evaluation of the acoustical characteristic of valves.

The noise characteristics to be determined are useful for the following reasons. a) to compare the performance of different valves; b) to plan measures for noise abatement; c) to determine acoustical characteristics of valves and valve assemblies; d) to enable proper sizing of sound absorbers; e) to determine possible adverse effects on ultra-sonic flow meter measurements.

Found what you need?

Document preview — GB/T 17213.8-2015

National Standard of the People's Republic of China

ICS
23.060.40; 25.040.40
Classification
N 16

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope7
  • 2 Normative references7
  • 3 Terms and definitions8
  • 4 Symbols9
  • 5 Method A (external sound pressure measurement)10
  • 6 Method B (internal sound pressure measurement)16

1 Scope

This Part of GB/T 17213 defines equipment, methods, and procedures for obtaining laboratory measurements of sound pressure levels radiated by control valves and/or associated piping configurations, including fixed restrictions, through which compressible fluids are passing.

Control valves discharging to atmosphere are excluded from this Part.

Method A is a uniform method of measuring the radiated noise from the valve and associated test piping and allows a comparison of various measuring results which is beneficial for both user and manufacturer. The noise criteria are expressed by determining the sound pressure level of the valve under consideration.

Method B is a procedure for measuring the sound pressure levels within pipe systems upstream and downstream of the valve under fixed operating conditions. Since inaccuracies due to the pipe transmission are eliminated, this method is preferred for evaluation of the acoustical characteristic of valves.

The noise characteristics to be determined are useful for the following reasons.

a) to compare the performance of different valves;

b) to plan measures for noise abatement;

c) to determine acoustical characteristics of valves and valve assemblies;

d) to enable proper sizing of sound absorbers;

e) to determine possible adverse effects on ultra-sonic flow meter measurements.

2 Normative references

The following referenced documents are indispensable for the application of this

15) Piping geometry factor, Fp 1

16) Any deviation from this standard

NOTE. Volumetric flow rates in m3/h refer to normal conditions, which are 0 °C and 101.325 kPa (1.01325 bar), or standard conditions, which are 15.6 °C and 101.325 kPa (1.01325 bar).

6.2.8 Accuracy

The overall accuracy of this method is limited to ± 3 dB.

6.3 Data evaluation

The data shall be evaluated in accordance with IEC 60534-8-3. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 17213.8-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17213.8-2015

$115.00