GB/T 16886.9-2022Biological evaluation of medical devices - Part 9: Framework for identification and quantification of potential degradation products (English PDF)
Also coversGBT16886.9-2022
Open the GB/T 16886.9-2022 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 30, 2022
Implementation date
January 1, 2024
Scope
GB/T 16886.9-2022 (Biological evaluation of medical devices - Part 9: Framework for identification and quantification of potential degradation products) is available as an English-translated PDF.
GB/T 16886.9-2022 — This Document provides general principles for the systematic evaluation of the potential and observed degradation of medical devices through the design and performance of in vitro degradation studies. Information obtained from these studies can be used in the biological evaluation described in the GB/T (Z) 16886 series.
Document preview — GB/T 16886.9-2022
National Standard of the People's Republic of China
Issued by: SAMR; SAC
Contents
- Foreword...3
- Introduction...5
- 1 Scope...8
- 2 Normative References...8
- 3 Terms and Definitions...9
- 4 Principles for Design of Degradation Studies...10
- 4.1 General...10
- 4.2 Preliminary considerations...11
- 4.3 Study design...11
- 4.4 Characterization of degradation products from medical devices...12
- 5 Study Report...13
- Annex A (Normative) Consideration of the Need for Degradation Studies...14
- Annex B (Informative) Degradation Study Considerations...16
- Bibliography...19
Foreword
This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for
Standardization - Part 1.Rules for the Structure and Drafting of Standardizing Documents.
This Document is Part 9 of GB/T (Z) 16886 Biological Evaluation of Medical Devices. GB/T
(Z) 16886 has published the following parts.
--- Part 1.Evaluation and Testing within a Risk Management Process;
--- Part 2.Animal Welfare Requirements;
--- Part 3.Tests for Genotoxicity, Carcinogenicity and Reproductive Toxicity;
--- Part 4.Selection of Tests for Interactions with Blood;
--- Part 5.Tests for in Vitro Cytotoxicity;
--- Part 6.Tests for Local Effects after Implantation;
--- Part 7.Ethylene Oxide Sterilization Residuals;
--- Part 9.Framework for Identification and Quantification of Potential Degradation
Products;
--- Part 10.Tests for Irritation and Skin Sensitization;
--- Part 11.Tests for Systemic Toxicity;
--- Part 12.Sample Preparation and Reference Materials;
--- Part 13.Identification and Quantification of Degradation Products from Polymeric
Medical Devices;
--- Part 14.Identification and Quantification of Degradation Products from Ceramics;
--- Part 15.Identification and Quantification of Degradation Products from Metals and
Alloys;
--- Part 16.Toxicokinetic Study Design for Degradation Products and Leachable;
--- Part 17.Establishment of Allowable Limits for Leachable Substances;
--- Part 18.Chemical Characterization of Medical Device Materials within a Risk
Management Process;
--- Part 19.Physic-Chemical Morphological and Topographical Characterization of
Materials;
--- Part 20.Principles and Methods for Immunotoxicology Testing of Medical Devices;
--- Part 22.Guidance to Nanomaterials.
This Document replaced GB/T 16886.9-2017 Biological Evaluation of Medical Devices - Part
9 Framework for Identification and Quantification of Potential Degradation Products.
Compared with GB/T 16886.9-2017, the major technical changes of this Document are as
follows besides the structural adjustments and editorial modifications.
a) Change "biodegradation" to "degradation" (see Clause 1, 4.1, 4.3, 4.4, Annex B of this
Edition; Clause 1, 4.1, 4.3, 4.4, Annex B of the 2017 Edition);
b) Add information on test methods for nanomaterials and related materials (see Clause 4 of
this Edition; Clause 4 of the 2017 Edition).
This Document equivalently adopts ISO 10993-9.2019 Biological Evaluation of Medical
Devices - Part 9.Framework for Identification and Quantification of Potential Degradation
Products.
Please note some contents of this Document may involve patents. The issuing agency of this
Document shall not assume the responsibility to identify these patents.
This Document was proposed by National Medical Products Administration.
This Document shall be under the jurisdiction of National Technical Committee on Biological
Evaluation on Medical Device of Standardization Administration of China (SAC/TC 248).
Drafting organizations of this Document. Shandong Institute of Medical Devices and Drug
Packaging Inspection; and Shandong Institute of Non-Metallic Materials.
Chief drafting staffs of this Document. Guo Lijuan, Du Fuying, Li Ying, Wu Changyan, Liu
Xia, and Peng Jian.
The historical editions replaced by this Document are as follows.
--- GB/T 16886.9-2001 was first-time published in 2001; and first-time revised in 2017;
--- It is the second-time revised hereby.
1 Scope
This Document provides general principles for the systematic evaluation of the potential and
observed degradation of medical devices through the design and performance of in vitro
degradation studies. Information obtained from these studies can be used in the biological
evaluation described in the GB/T (Z) 16886 series.
2 Normative References
The provisions in following documents become the essential provisions of this Document
through reference in this Document. For the dated documents, only the versions with the dates
indicated are applicable to this Document; for the undated documents, only the latest version
(including all the amendments) is applicable to this Document.
ISO 10993-1 Biological evaluation of medical devices - Part 1.Evaluation and testing
within a risk management process
3 Terms and Definitions
For the purposes of this document, the terms and definitions given in ISO 10993-1 and the
following apply.
Action of a non-endogenous (foreign) material or substance passing through or being
assimilated by cells and/or tissue over time.
4 Principles for Design of Degradation Studies
Careful consideration of the potential for intended or unintended degradation of a material is
essential to the evaluation of the biological safety of a device.
A degradation study plan complete with the purpose of the study shall be designed and
documented to address the issues identified in 4.1.
5 Study Report
The study report shall include the following information, where relevant.
Annex A
(Normative)
Consideration of the Need for Degradation Studies
Degradation studies shall be considered if.
Annex B
(Informative)
Degradation Study Considerations
This annex contains aspects that need to be considered in the evaluation of possible degradation.
Appropriate practical studies should be considered in the case where essential information is
missing on the degradation of devices or materials and the biological effects of potential
degradation products.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
How to Buy GB/T 16886.9-2022
- 1Add to cart. Click the "Buy GB/T 16886.9-2022" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization
GB/T 16886.15-2022 — Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys
Secure payment via Stripe
Payments accepted
GB/T 16886.9-2022
$215.00