GB/T 16886.18-2022Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process (English PDF)
Also coversGBT16886.18-2022
Open the GB/T 16886.18-2022 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 30, 2022
Implementation date
January 1, 2024
Scope
GB/T 16886.18-2022 (Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process) is available as an English-translated PDF.
GB/T 16886.18-2022 — This Document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization.
Document preview — GB/T 16886.18-2022
National Standard of the People's Republic of China
Issued by: SAMR; SAC
Contents
- Foreword...4
- Introduction...7
- 1 Scope...11
- 2 Normative References...12
- 3 Terms and Definitions...12
- 4 Abbreviated Terms...18
- 5 Characterization Procedure...19
- 5.1 General...19
- 5.2 Establish medical device configuration and material composition...22
- 5.2.1 General...22
- 5.2.2 Information gathering...23
- 5.2.3 Information generation...24
Foreword
This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for
Standardization - Part 1.Rules for the Structure and Drafting of Standardizing Documents.
This Document is Part 18 of GB/T (Z) 16886 Biological Evaluation of Medical Devices. GB/T
(Z) 16886 has published the following parts.
--- Part 1.Evaluation and Testing within a Risk Management Process;
--- Part 2.Animal Welfare Requirements;
--- Part 3.Tests for Genotoxicity, Carcinogenicity and Reproductive Toxicity;
--- Part 4.Selection of Tests for Interactions with Blood;
--- Part 5.Tests for in Vitro Cytotoxicity;
--- Part 6.Tests for Local Effects after Implantation;
--- Part 7.Ethylene Oxide Sterilization Residuals;
--- Part 9.Framework for Identification and Quantification of Potential Degradation
Products;
--- Part 10.Tests for Irritation and Skin Sensitization;
--- Part 11.Tests for Systemic Toxicity;
--- Part 12.Sample Preparation and Reference Materials;
--- Part 13.Identification and Quantification of Degradation Products from Polymeric
Medical Devices;
--- Part 14.Identification and Quantification of Degradation Products from Ceramics;
--- Part 15.Identification and Quantification of Degradation Products from Metals and
Alloys;
--- Part 16.Toxicokinetic Study Design for Degradation Products and Leachable;
--- Part 17.Establishment of Allowable Limits for Leachable Substances;
--- Part 18.Chemical Characterization of Medical Device Materials within a Risk
Management Process;
--- Part 19.Physic-Chemical Morphological and Topographical Characterization of
Materials;
--- Part 20.Principles and Methods for Immunotoxicology Testing of Medical Devices;
--- Part 22.Guidance to Nanomaterials.
This Document replaced GB/T 16886.18-2011 Biological Evaluation of Medical Devices -
Part 18.Chemical Characterization of Materials. Compared with GB/T 16886.18-2011, the
major technical changes of this Document are as follows besides the structural adjustments
and editorial modifications.
a) Change the scope (see Clause 1 of this Edition; Clause 1 of the 2011 Edition);
b) Add new terms and definitions (see Clause 3 of this Edition);
c) Change and add new abbreviations (see Clause 4 of this Edition; Clause 4 of the 2011
Edition);
d) Change "General Principles" to "General"; and further elaborate on the application of
chemical characterization and the relationship with risk assessment (see 5.1 of this
Edition; Clause 5, 6.1 of the 2011 Edition);
e) Change "Step 1 -- Qualitative information" into "Determine the structure and material
composition of medical devices"; and elaborate on the collection and generation of
information required for chemical characterization (see 5.2 of this Edition; 6.2 of the
2011 Edition);
f) Change "Step 2 -- Material equivalence" into "Evaluate material/chemical equivalence
with clinically established materials or medical devices"; and elaborate on
material/chemical equivalence in more detail (see 5.3 of this Edition; 6.3 of the 2011
Edition);
g) Change "Step 3 -- Quantitative information", "Step 4 - Quantitative risk assessment" and
"Step 5 - Estimating exposure to chemicals"; and describe in detail the progressive
generation steps for quantitative chemical characterization data used for risk assessment
(see 5.4, 5.5, 5.6, 5.7, 5.8, 5.9 of this Edition; 6.3, 6.4, 6.5 of the 2011 Edition);
h) Change the general rules in "Chemical characterization parameters and methods"; and
add a description about the dissolution test (see 6.1 of this Edition; 7.1 of the 2011
edition);
i) Classify and integrate the characterization parameters and test methods of polymers,
metals and alloys, ceramics and natural macromolecules; and make some changes (see
6.2, 6.4 of this Edition; 7.2, 7.3, 7.4, 7.5 of the 2011 Edition);
j) Change "Report of obtained data" into "Report of chemical characterization data"; and
change the information to be included in the report (see Clause 7 of this Edition; Clause
8 of the 2011 Edition);
k) Change the chemical characterization flow chart (see Figures 1~ 4 of this Edition; Figure
A.1 of the 2011 Edition).
This Document equivalently adopts ISO 10993-18.2020 Biological Evaluation of Medical
Devices - Part 18.Chemical Characterization of Medical Device Materials within a Risk
Management Process.
This Document made the minimum editorial modification as follows.
--- Incorporated the amendments of ISO 10993-18.2020/Amd.1.2022; and the outer margins
of the terms involved are marked with vertical double lines (||).
Please note some contents of this Document may involve patents. The issuing agency of this
Document shall not assume the responsibility to identify these patents.
This Document was proposed by National Medical Products Administration.
This Document shall be under the jurisdiction of National Technical Committee on Biological
Evaluation on Medical Device of Standardization Administration of China (SAC/TC 248).
Drafting organizations of this Document. Shandong Institute of Medical Devices and Drug
Packaging Inspection; and Baxter Healthcare (Suzhou) Co., Ltd.
Chief drafting staffs of this Document. Shen Yong, Luo Hongyu, Bo Xiaowen, Liu Aijuan, and
Lu Qin.
The historical editions replaced by this Document are as follows.
--- GB/T 16886.18-2011 was first-time published in 2011;
--- It is the first-time revised hereby.
1 Scope
This Document specifies a framework for the identification, and if necessary, quantification of
constituents of a medical device, allowing the identification of biological hazards and the
estimation and control of biological risks from material constituents, using a generally stepwise
approach to the chemical characterization.
2 Normative References
The provisions in following documents become the essential provisions of this Document
through reference in this Document. For the dated documents, only the versions with the dates
indicated are applicable to this Document; for the undated documents, only the latest version
(including all the amendments) is applicable to this Document.
ISO 10993-1 Biological evaluation of medical devices - Part 1.Evaluation and testing
within a risk management process
3 Terms and Definitions
For the purposes of this document, the definitions in ISO 10993-1 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following
addresses.
Method whose purpose is to discover, identify and semi-quantitatively estimate the
concentration of all relevant analytes in a test sample above an established reporting threshold
(such as the AET).
4 Abbreviated Terms
The abbreviated terms given in Table 1 are used in this document.
5 Characterization Procedure
A medical device's ability to interact with a potentially affected individual requires contact, as
established in ISO 10993-1.For medical devices (or components) that do not have direct or
indirect contact with the body, chemical characterization is not necessary. The hypothetical
worst-case chemical release is established by the configuration and composition of the medical
device.
6 Chemical Characterization Parameters and Methods
Analytical methods used in chemical characterization generally serve one of two purposes.
screening samples for unspecified analytes and testing samples for specified (targeted) analytes.
The purpose of a screening analysis is to reveal analytes present in the sample above a relevant
reporting threshold (e.g., AET), to estimate the concentration of such analytes, and to secure
the identities of such analytes. The purpose of a targeting analysis is to accurately and precisely
establish the concentration of the specified (targeted) and identified analytes in the sample.
7 Reporting of the Chemical Characterization Data
The purpose of a chemical assessment report is to provide information that enables the review
of chemical characterization data and supports the toxicological risk assessment of this
information.
Types of information that can be included in a report to facilitate the toxicological risk
assessment and the review of the analytical data and procedures are listed in Annex G.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
ISO 10993
Cited by
How to Buy GB/T 16886.18-2022
- 1Add to cart. Click the "Buy GB/T 16886.18-2022" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.1-2022 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.10-2024 — Biological evaluation of medical devices - Part 10: Tests for skin sensitization
GB/T 16886.15-2022 — Biological evaluation of medical devices - Part 15: Identification and quantification of degradation products from metals and alloys
Secure payment via Stripe
Payments accepted
GB/T 16886.18-2022
$275.00