GB/T 10066.2-2019Test methods for electroheating and electromagnetic processing installations -- Part 2: Direct arc furnaces (English PDF)
电热和电磁处理装置的试验方法 第2部分:直接电弧炉
This is a limited preview
Buy now to download the full PDF (30 pages)
Need quotation for your management?
Get a formal quotation for GB/T 10066.2-2019 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
August 30, 2019
Implementation date
March 1, 2020
Scope
GB/T 10066.2-2019 is the English-translated version of 电热和电磁处理装置的试验方法 第2部分:直接电弧炉.
GB/T 10066.2-2019 is the Chinese standard "Test methods for electroheating and electromagnetic processing installations -- Part 2: Direct arc furnaces". Its scope clause reads: This part of GB/T 10066 specifies the test procedures, conditions and methods for electric arc furnace (EAF), based on which the capacity is determined.
Main parameters and main operating characteristics of AC electric arc furnace (EAFac) or DC electric arc furnace (EAFdc) above 500kg/furnace.
The electric arc furnace technology is also suitable for this type of furnace, ie the liquid metal in the furnace is kept at a high temperature or superheated to the pouring temperature [eg a steel ladle using AC) Furnace (LF)].
Test methods for certain special equipment, such as DC arc furnace controlled rectifiers, are specified in IEC 60146-1-1. The test method for the submerged arc furnace (SAF) is specified in IEC 60683. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 10066.2-2019
National Standard of the People's Republic of China
- ICS
- 25.180.10
- Classification
- K 61
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Characteristics of the electric arc furnace system
- 4.1 General Terms
- 4.2 Electric assembly of electric arc furnace
- 4.3 Furnace structure
- 4.4 Water cooling
- 5 General test conditions for test type and its performance
- 5.1 General requirements
- 5.2 Cold and hot test items
- 6 Technical Test
- 6.1 Electrical insulation of high current systems
- 6.2 Cooling water system
- 6.3 Electrode moving speed
- 6.4 Short circuit test procedure
- 6.5 Main characteristics during operation of the electric arc furnace
- 6.6 Electrode consumption
- 6.7 Phase sequence
- 6.8 Electric Arc Furnace - Rated Capacity
1 Scope
This part of GB/T 10066 specifies the test procedures, conditions and methods for electric arc furnace (EAF), based on which the capacity is determined.
Main parameters and main operating characteristics of AC electric arc furnace (EAFac) or DC electric arc furnace (EAFdc) above 500kg/furnace.
The electric arc furnace technology is also suitable for this type of furnace, ie the liquid metal in the furnace is kept at a high temperature or superheated to the pouring temperature [eg a steel ladle using AC)
Furnace (LF)].
Test methods for certain special equipment, such as DC arc furnace controlled rectifiers, are specified in IEC 60146-1-1.
The test method for the submerged arc furnace (SAF) is specified in IEC 60683.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 60398.1999 General test methods for industrial electrothermal installations (Industrial electroheatinginstalations-General
Testmethods)
Safety of electroheat installations - Part 1. General requirements (Safetyinelectroheatinginstalations-
Part 1. Generalrequirements)
Safety of electroheat installations - Part 4. Particular requirements for electric arc furnace installations (Safetyinelectroheatinstal- lations-Part 4.Particularrequirementsforarcfurnaceinstalations)
3 Terms and definitions
The following terms and definitions as defined in IEC 60519-1.2010 apply to this document.
Note. The general definition refers to IEC 60050 International Electrotechnical Vocabulary. Terms related to industrial heating are specified in IEC 60050-841.
3.1 Active power
The average value of the instantaneous power p (kW) in the cycle time T(h) in the periodic state.
P=
Tintegral
Pdt
Note. The active power instantaneous value (root mean square value) can be measured at any time, including all phases.
[IEC 60050-131.2002, 131-11-42, revised]
3.2 Apparent power
The rated power (MVA) of the transformer that supplies the electric arc furnace.
S= 3UI
GB/T 37752.1 | GB/T 5959.41 | GB/T 31137 | GB/T 10066.1 | GB/T 10066.6 | GB/T 10066.11 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60398.1999
How to Download GB/T 10066.2-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10066.3-2014 — Test methods for electroheat installations -- Part 3: Induction channel furnaces and induction crucible furnace
GB/T 10066.1-2019 — Test methods for electroheating and electromagnetic processing installations -- Part 1: General
GB/T 10066.4-2004 — Test methods for electro-heat installations -- Part 4: Indirect resistances furnaces
Secure payment via Stripe