GB 9706.227-2021Medical electrical equipment—Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment (English PDF)

医用电气设备 第2-27部分:心电监护设备的基本安全和基本性能专用要求

Preview PDF

Also coversGB9706.227-2021

This is a limited preview

Buy now to download the full PDF

Need quotation for your management?

Get a formal quotation for GB 9706.227-2021 in 30 minutes.

Issued by

State Administration for Market Regulation; Standardization Administration of China

Level / Type

National · Mandatory

Issue date

October 11, 2021

Implementation date

May 1, 2023

Scope

GB 9706.227-2021 is the English-translated version of 医用电气设备 第2-27部分:心电监护设备的基本安全和基本性能专用要求.

Clause 1 of the general standard applies, except as follows.

Found what you need?

Document preview — GB 9706.227-2021

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C39

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • Foreword...3
  • Introduction...7
  • 201.1 Scope, Object and Related Standards...9
  • 201.2 Normative References...11
  • 201.3 Terms and Definitions...11
  • 201.4 General Requirements...13
  • 201.5 General Requirements for Testing of ME EQUIPMENT...14
  • 201.6 Classification of ME EQUIPMENT and ME SYSTEMS...15
  • 201.7 ME EQUIPMENT Identification, Marking and Documents...15
  • 201.8 Protection against Electrical HAZARDS from ME EQUIPMENT...20

Foreword

This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for

Standardization – Part 1.Rules for the Structure and Drafting of Standardizing Documents.

This Document is Part 2-27 of GB 9706 Medical Electrical Equipment. GB 9706 has published

the following parts.

--- Part 1.General requirements for basic safety and essential performance;

--- Part 1-3.General requirements for basic safety and essential performance—Collateral

Standard. Radiation protection in diagnostic X-ray equipment;

--- Part 2-1.Particular requirements for the basic safety and essential performance of

electron accelerators in the range 1 MeV to 50 MeV;

--- Part 2-2.Particular requirements for the basic safety and essential performance of high

frequency surgical equipment and high frequency surgical accessories;

--- Part 2-3.Particular requirements for the basic safety and essential performance of short-

wave therapy equipment;

--- Part 2-4.Particular requirements for the basic safety and essential performance of cardiac

defibrillators;

--- Part 2-5.Particular requirements for the basic safety and essential performance of

ultrasonic physiotherapy equipment;

--- Part 2-6.Particular requirements for the basic safety and essential performance of

microwave therapy equipment;

--- Part 2-8.Particular requirements for the basic safety and essential performance of

therapeutic X-ray equipment operating in the range 10 kV to 1 MV;

--- Part 2-11.Particular requirements for the basic safety and essential performance of

gamma beam therapy equipment;

--- Part 2-12.Particular requirements for basic safety and essential performance of critical

care ventilators;

--- Part 2-13.Particular requirements for the basic safety and essential performance of an

anaesthetic workstation;

--- Part 2-16.Particular requirements for the basic safety and essential performance of

hemodialysis, hemodiafiltration and hemofiltration equipment;

--- Part 2-17.Particular requirements for the basic safety and essential performance of

automatically-controlled brachytherapy after-loading equipment;

--- Part 2-18.Particular requirements for the basic safety and essential performance of

endoscopic equipment;

--- Part 2-19.Particular requirements for the basic safety and essential performance of infant

incubators;

--- Part 2-22.Particular requirements for basic safety and essential performance of surgical,

cosmetic, therapeutic and diagnostic laser equipment;

--- Part 2-24.Particular requirements for the basic safety and essential performance of

infusion pumps and controllers;

--- Part 2-25.Particular requirements for the basic safety and essential performance of

electrocardiographs;

--- Part 2-26.Particular requirements for the basic safety and essential performance of

electroencephalographs;

--- Part 2-27.Particular requirements for the basic safety and essential performance of

electrocardiographic monitoring equipment;

--- Part 2-28.Particular requirements for the basic safety and essential performance of X-

ray tube assemblies for medical diagnosis;

--- Part 2-29.Particular requirements for the basic safety and essential performance of

radiotherapy simulators;

--- Part 2-36.Particular requirements for the basic safety and essential performance of

equipment for extracorporeally induced lithotripsy;

--- Part 2-37.Particular requirements for the basic safety and essential performance of

ultrasonic medical diagnostic and monitoring equipment;

--- Part 2-39.Particular requirements for basic safety and essential performance of

peritoneal dialysis equipment;

--- Part 2-43.Particular requirements for the basic safety and essential performance of X-

ray equipment for interventional procedures;

--- Part 2-44.Particular requirements for the basic safety and essential performance of X-

ray equipment for computed tomography;

--- Part 2-45.Particular requirements for the basic safety and essential performance of

mammographic X-ray equipment and mammographic stereotactic devices;

--- Part 2-54.Particular requirements for the basic safety and essential performance of X-

ray equipment for radiography and radioscopy;

--- Part 2-60.Particular requirements for the basic safety and essential performance of dental

equipment;

--- Part 2-63.Particular requirements for the basic safety and essential performance of dental

extra-oral X-ray equipment;

--- Part 2-65.Particular requirements for the basic safety and essential performance of dental

intra-oral X-ray equipment;

--- Part 2-66.Particular requirements for the basic safety and essential performance of

hearing instruments and hearing instrument systems.

This Document replaced GB 9706.25-2005 Medical Electrical Equipment - Part 2.Particular

Requirements for the Safety of Electrocardiographic Monitoring Equipment. Compared with

GB 9706.25-2005, the major technical changes of this Document are as follows besides the

structural adjustments and editorial modifications.

--- Integrate all the contents of YY 1079-2008;

--- Add energy reduction test (see 201.8.5.5.2);

--- Add performance requirements (see 201.12.1), and specify basic performance (see Table

201.101);

--- Add EMC requirements (see 202);

--- Add alarm requirements (see 208);

--- Change the experimental circuit diagram of the defibrillation protection effect (see Figure

201.102, Figure 201.103 of this Edition; Figure 104, Figure 105 of the 2005 Edition);

--- Delete the requirement for electrode polarization recovery time after defibrillation (see

51.102 of the 2005 Edition).

This Document used the redrafting method to modify and adopt IEC 60601-2-27.2011 Medical

Electrical Equipment – Part 2-27.Particular Requirements for the Basic Safety and Essential

Performance of Electrocardiographic Monitoring Equipment.

The technical differences and causes between this Document and IEC 60601-2-27.2011 are as

follows.

--- Regarding normative references, this Document has been adjusted with technical

differences to adapt to China's technical conditions. The adjustments are reflected in

201.2 "Normative References". The specific adjustments are as follows.

- Use GB 9706.202 that modified and adopted international standard to replace IEC

60601-2-2.2009;

- Use YY 9706.102-2021 that modified and adopted international standard to replace

IEC 60601-1-2.2007;

- Use YY 9706.108-2021 that modified and adopted international standard to replace

IEC 60601-1-8.2008;

- Add GB/T 4208-2017;

- Delete IEC 60601-2-49.

This Document made the following editorial modifications.

--- Incorporate the contents of the technical corrigendum IEC 60601-2-27.2011/COR1.2012;

corresponding clause;

--- Modify the editorial error; and change the value of "pulse burst interval b, c (tb)" in the

third column of "Low priority alarm signal" in Table 208.102 into "2.5s~30s";

--- Delete terminology index.

Please note some contents of this Document may involve patents. The issuing agency of this

Document shall not assume the responsibility to identify these patents.

This Document was proposed by and under the jurisdiction of National Medical Products

Administration.

The historical editions replaced by this Document are as follows.

--- GB 9706.25-2005 was first-time published in 2005;

--- It is first-time revised hereby.

201.1 Scope, Object and Related Standards

Clause 1 of the general standard applies, except as follows.

201.2 Normative References

The following documents are essential to the application of this Document. For the dated

documents, only the versions with the dates indicated are applicable to this Document; for the

undated documents, only the latest version (including all the amendments) is applicable to this

Document.

201.4 General Requirements

Clause 4 of the general standard applies, except as follows.

201.6 Classification of ME EQUIPMENT and ME SYSTEMS

Clause 6 of the general standard applies, except as follows.

201.7 ME EQUIPMENT Identification, Marking and Documents

Clause 7 of the general standard applies, except as follows.

201.8 Protection against Electrical HAZARDS from ME EQUIPMENT

Clause 8 of the general standard applies, except as follows.

201.9 Protection against MECHANICAL HAZARDS of ME

EQUIPMENT and ME SYSTEMS

Clause 9 of the general standard applies.

201.10 Protection against Unwanted and Excessive Radiation

HAZARDS

Clause 10 of the general standard applies.

201.11 Protection against Excessive Temperatures and Other

HAZARDS

Clause 11 of the general standard applies, except as follows.

201.12 Accuracy of Controls and Instruments and Protection

against Hazardous Outputs

Clause 12 of the general standard applies, except as follows.

201.13 HAZARDOUS SITUATIONS and Fault Conditions

Clause 13 of the general standard applies.

201.14 PROGRAMMABLE ELECTRICAL MEDICAL

SYSTEMS (PEMS)

Clause 14 of the general standard applies.

201.15 Construction of ME EQUIPMENT

Clause 15 of the general standard applies, except as follows.

201.16 ME SYSTEMS

Clause 16 of the general standard applies.

201.17 Electromagnetic Compatibility of ME EQUIPMENT and ME SYSTEMS

Clause 17 of the general standard applies, except as follows.

202 Electromagnetic Compatibility – Requirements and Tests

YY 9706.102-2021 applies except as follows.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Download GB 9706.227-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 9706.227-2021

$880.00