GB 9706.222-2022Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment (English PDF)

Also coversGB9706.222-2022

Open the GB 9706.222-2022 preview as PDF

Preview — first pages of GB 9706.222-2022

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Mandatory

Issue date

March 15, 2022

Implementation date

May 1, 2024

Scope

GB 9706.222-2022 (Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment) is available as an English-translated PDF.

GB 9706.222-2022 — replace. This document specifies the basic safety and essential performance of laser equipment for use in surgery, therapy, diagnosis, and shaping, which are classified as containing Class 1C, 3B or 4 laser products with Class 3B or Class 4 enclosed lasers. In this document, medical electrical equipment or medical electrical systems that transmit laser light as an energy source to a patient are referred to as "laser equipment". Note 1.Laser products classified as Class 1, Class 1M, Class 2, Class 2M or Class 3R in these applications are applicable to GB 7247.1-2012 and the general standard. If a chapter or article applies only to ME EQUIPMENT or ME SYSTEMS, the title and content of that chapter or article will clearly state this. if Without expressly stated, this chapter or subclause applies to related ME EQUIPMENT and ME SYSTEM. With the exception of general standard 7.2.13 Physiological effects, specific requirements within the scope of this document do not cover inherent hazards to the intended physiological function of laser devices risk (source). Note 2 to entry. See General Standard 4.2 Risk Management Process for ME EQUIPMENT or ME SYSTEMS. Note 3.If the laser equipment is classified into class 1C and used for domestic use, the laser equipment complies with IEC 60335-2-113.2016.

Document preview — GB 9706.222-2022

National Standard of the People's Republic of China

Classification
C 43

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • foreword
  • Introduction
  • 201.1 Scope, Purpose and Related Standards

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"

drafted.

This document is part 2-22 of GB 9706 "Medical Electrical Equipment". GB 9706 has released the following parts.

--- Part 1.General requirements for basic safety and basic performance;

--- Part 1-3.General Requirements for Basic Safety and Essential Performance Collateral Standard. Radiation Protection of Diagnostic X-ray Equipment;

--- Part 2-1.Specific requirements for basic safety and basic performance of electron accelerators with energies from 1MeV to 50MeV;

--- Part 2-2.Special requirements for basic safety and basic performance of high-frequency surgical equipment and high-frequency accessories;

--- Part 2-3.Specific requirements for basic safety and basic performance of shortwave therapy equipment;

--- Part 2-5.Specific requirements for the basic safety and basic performance of ultrasonic physiotherapy equipment;

--- Part 2-6.Specific requirements for basic safety and basic performance of microwave therapy equipment;

--- Part 2-8.Particular requirements for basic safety and basic performance of therapeutic X-ray equipment with energy from 10kV to 1MV;

--- Part 2-11.Particular requirements for basic safety and basic performance of gamma beam therapy equipment;

--- Part 2-12.Specific requirements for basic safety and basic performance of critical care ventilators;

--- Part 2-13.Particular requirements for basic safety and basic performance of anesthesia workstations;

--- Part 2-16.Particular requirements for basic safety and basic performance of hemodialysis, hemodiafiltration and hemofiltration equipment;

--- Part 2-17.Special requirements for the basic safety and basic performance of automatically controlled brachytherapy afterloading equipment;

--- Part 2-18.Particular requirements for basic safety and basic performance of endoscopic equipment;

--- Part 2-19.Specific requirements for the basic safety and basic performance of infant incubators;

--- Part 2-22.Particular requirements for the basic safety and basic performance of laser equipment for surgical, orthopedic, therapeutic and diagnostic use;

--- Part 2-24.Particular requirements for basic safety and basic performance of infusion pumps and infusion controllers;

--- Part 2-25.Particular requirements for basic safety and basic performance of electrocardiographs;

--- Part 2-26.Specific requirements for basic safety and basic performance of EEG machines;

--- Part 2-27.Particular requirements for basic safety and basic performance of ECG monitoring equipment;

--- Part 2-28.Particular requirements for basic safety and basic performance of medical diagnostic X-ray tube assemblies;

--- Part 2-29.Specific requirements for basic safety and basic performance of radiotherapy simulators;

--- Part 2-36.Particular requirements for the basic safety and basic performance of in vitro induced lithotripsy equipment;

--- Part 2-37.Particular requirements for basic safety and basic performance of ultrasonic diagnostic and monitoring equipment;

--- Part 2-39.Particular requirements for basic safety and basic performance of peritoneal dialysis equipment;

--- Part 2-43.Particular requirements for basic safety and basic performance of interventional X-ray equipment;

--- Part 2-44.Particular requirements for the basic safety and basic performance of X-ray computed tomography equipment;

--- Part 2-45.Special use for basic safety and basic performance of mammography equipment and mammography stereotaxic devices

Require;

--- Part 2-54.Particular requirements for basic safety and basic performance of X-ray photography and fluoroscopy equipment;

--- Part 2-60.Particular requirements for basic safety and basic performance of dental equipment;

--- Part 2-63.Special requirements for basic safety and basic performance of dental X-ray machines for extraoral imaging;

--- Part 2-65.Special requirements for basic safety and basic performance of intraoral imaging dental X-ray machines.

This document replaces GB 9706.20-2000 "Medical electrical equipment - Part 2.Special requirements for the safety of diagnostic and therapeutic laser equipment

Compared with GB 9706.20-2000, in addition to structural adjustment and editorial changes, the main technical changes are as follows.

--- The general part refers to GB 9706.1-2020;

--- Modified the scope and purpose (see Chapter 1 of.201.1,.2000 edition);

--- Added normative references (see.201.2);

--- Delete the terms "aiming spot", "(medical) laser equipment", "shutter" and "working laser" (see 2.1.103 of the.2000 edition,

2.1.111, 2.1.116 and 2.1.121);

---Added "Class 1C", "Enclosed Laser", "Good Contact", "Laser Emission Control Switch", "Laser Operator", "Maximum Allowable Irradiation"

terms and definitions of "quantity" and "stray light radiation" (see.201.3.206,.201.3.212,.201.3.213,.201.3.214,.201.3.217,

201.3.220 and.201.3.224);

--- Merge the term "laser output" into the terms "laser energy" and "laser power". (See.201.3.216 and.201.3.218,.2000

versions 2.1.110, 2.1.112 and 2.1.113);

--- Modified the terms "operator protection filter", "target indicating device", "working beam" (see.201.3.221,.201.3.225 and

201.3.227, 2.1.115, 2.1.118 and 2.1.120 of the.2000 edition);

--- Modified the term "preparation" and the part of the standard involving "preparation" [see.201.3.219,.201.3.222,.201.10.4.101d),

Chapter 32 d), Chapter 32 e), 56.101, 104 of Table D1, 105 of Table D1];

--- Revised the requirements for ME equipment identification, marking and documentation (see Chapter 6 of.201.7,.2000 edition);

--- Added "It is necessary to give information that the measuring equipment has been periodically calibrated to meet the requirements of the corresponding technical regulations." [See.201.7.9.2.101f)];

--- Added requirements for "parts isolation" (see.201.8.5);

--- Deleted "If the laser equipment has an emergency terminator that meets the requirements of IEC 60947-3, it is not required to have an emergency laser termination.

stopper" (see 51.101 of the.2000 edition);

---Added the requirement of "Laser", and integrated the original standard "Light Radiation", "Enclosure and Cover" and "Standby/Ready" modification and integration

into this clause. At the same time, "restrictions on laser output", "interlocking system for Class 1C laser equipment", "optical

"Laser radiation filters in observers" requirements. (see.201.10.4, Chapters 32, 55 and 56.101 of the.2000 edition);

--- Added requirements for "spectral impurity" (see.201.12.4.4.102);

--- Deleted the requirement of "creepage distances and clearances" (57.10 of the.2000 edition);

--- Revised "ME EQUIPMENT HAZARDOUS CONDITIONS AND FAILURE STATES", replacing the original standard "abnormal operation and fault status" and "timer" parts.

Sub-modifications were incorporated into this clause, adding the requirements for "excessive laser output" and "irradiation termination failure after loss of good contact"

(see Chapter 52 and 56.102 of.201.13,.2000 edition).

This document uses the redrafting method to modify and adopt IEC 60601-2-22.2019 "Medical Electrical Equipment Part 2-22.Surgery, Plastic Surgery,

Particular requirements for the basic safety and essential performance of laser equipment for therapeutic and diagnostic use.

The technical differences between this document and IEC 60601-2-22.2019 and their reasons are as follows.

--- Regarding normative reference documents, this document has made adjustments with technical differences to adapt to the technical conditions of our country and the circumstances of the adjustment.

The situation is reflected in the "normative reference documents", and the specific adjustments are as follows.

* Replacing IEC 60601-1.2012 with GB 9706.1-2020 which has been modified to adopt international standards;

* Replace IEC 60825-1.2014 with GB 7247.1-2012 which is equivalent to adopting international standards.

---Because there is no requirement for emergency terminators in IEC 60947-3, and this clause has been deleted in the discussion draft of the new edition of IEC 60601-2-57, so

Deleted.201.12.4.4.101 "If the laser equipment has an emergency terminator that meets the requirements of IEC 60947-3, do not

Requires emergency laser terminators. "

--- Since.201.12.4.4.101 deleted the relevant clauses of IEC 60947-3, the referenced IEC 60947-3 was deleted.

---Because IEC /T R60878.2003 has been obsolete, the current effective one is IEC /T R60878.2015, so delete the footnote a of Table D.1

The year number in IEC /T R60878.

--- Added.201.7.9.2.101f) "To give the information that the measuring equipment has been calibrated regularly to meet the requirements of the corresponding technical regulations."

The following editorial changes have been made to this document.

--- Deleted "Shaping" in Note 3 of.201.7.9.2.101;

--- Deleted the term index of the International Standard.

Please note that certain content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents.

Introduction

Medical electrical equipment safety standards, also known as the 9706 series of standards, consist of general standards, side-by-side standards, specific standards, guidelines and interpretations.

---General standard. Medical electrical equipment should be generally applicable to safety standards, that is, equipment that meets the definition of medical electrical equipment should meet this

Basic standard requirements.

--- Side-by-side standard. Medical electrical equipment should be generally applicable to the safety standards, but in most cases only limited to some specific functions or special

Only devices that are sexual are required to meet the requirements of such standards.

---Special standard. a safety standard applicable to a certain type of medical electrical equipment, and not all medical electrical equipment has special

standard.

---Guidelines and interpretations. interpretations of the application guidelines and clauses of the relevant requirements in the standards involved.

In the GB 9706 series of standards, in addition to the published standards and this document, the planned standards are as follows.

--- Part 2-4.Particular requirements for basic safety and basic performance of cardiac defibrillators. The aim is to establish the basics of a cardiac defibrillator

Specific requirements for safety and essential performance.

--- Part 2-66.Specific requirements for the basic safety and basic performance of hearing devices and hearing device systems. The purpose is to establish a listening

Particular requirements for basic safety and basic performance of force equipment and hearing equipment systems.

This document addresses basic safety and essential performance requirements for surgical, orthopedic, therapeutic and diagnostic laser equipment. This document modifies and supplements

GB 9706.1-2020 "Medical Electrical Equipment Part 1.General Requirements for Basic Safety and Basic Performance".

In this document, an asterisk (*) is used as the first character of a title or the beginning of a paragraph or table title, indicating that there is a reference to this item in Appendix AA.

Specific guidelines and principles related to the project are provided. The relevant content of Appendix AA will not only help to use this document correctly, but also add it in a timely manner.

Rapid process of revision of standards due to changes in clinical practice or technological developments.

Medical Electrical Equipment Part 2-22.Surgical, Orthopaedic,

Basic safety and

Specific requirements for basic performance

201.1 Scope, Purpose and Related Standards

Except as described below, Chapter 1 of the General Standard applies.

201.1.1 Scope

replace.

This document specifies the basic safety and essential performance of laser equipment for use in surgery, therapy, diagnosis, and shaping, which are classified as containing

Class 1C, 3B or 4 laser products with Class 3B or Class 4 enclosed lasers.

In this document, medical electrical equipment or medical electrical systems that transmit laser light as an energy source to a patient are referred to as "laser equipment".

Note 1.Laser products classified as Class 1, Class 1M, Class 2, Class 2M or Class 3R in these applications are applicable to GB 7247.1-2012 and the general standard.

If a chapter or article applies only to ME EQUIPMENT or ME SYSTEMS, the title and content of that chapter or article will clearly state this. if

Without expressly stated, this chapter or subclause applies to related ME EQUIPMENT and ME SYSTEM.

With the exception of general standard 7.2.13 Physiological effects, specific requirements within the scope of this document do not cover inherent hazards to the intended physiological function of laser devices

risk (source).

Note 2 to entry. See General Standard 4.2 Risk Management Process for ME EQUIPMENT or ME SYSTEMS.

Note 3.If the laser equipment is classified into class 1C and used for domestic use, the laser equipment complies with IEC 60335-2-113.2016.

201.1.2 Purpose

replace.

The purpose of this document is to specify safety-specific requirements for the basic safety and essential performance of surgical, orthopedic, therapeutic and diagnostic laser equipment.

201.1.3 Tied standards

Added.

This document refers to Chapter 2 of the General Standard and the applicable collateral standards listed in.201.2 of this document.

201.1.4 Particular standards

Added.

In the GB 9706 series, the special standard may modify, replace or delete the general standard and the parallel standard according to the special ME EQUIPMENT under consideration.

requirements contained in the standard. Other basic safety and basic performance requirements may be supplemented.

The requirements of the specific standard take precedence over the requirements of the general standard.

GB 9706.1-2020 is referred to as the general standard in this document. Collateral standards are indicated by their respective document numbers.

The prefix "201" before the numbering of chapters and articles in this document corresponds to the general standard (for example,.201.1 in this document corresponds to the general standard

Chapter 1), or add the prefix "20x" to correspond to the applicable collateral standard, where "x" is the last digit of the corresponding international standard number for the collateral standard

Numbers (for example, 202.4 in this document corresponds to the content of Chapter 4 of the collateral standard YY9706.102, and 203.4 in this document corresponds to the collateral standard

Contents of Chapter 4 in GB 9706.103, etc.).

Changes to the Common Criteria text are governed by the use of the following words.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Buy GB 9706.222-2022

  1. 1Add to cart. Click the "Buy GB 9706.222-2022" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 9706.222-2022

$365.00

$310.00for partners