GB 8058-2003Standard permissible limits and testing method for release of lead or cadmium from ceramic cookware (English PDF)
陶瓷烹调器铅、镉溶出量允许极限和检测方法
Also coversGB8058-2003
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB 8058-2003 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Mandatory
Issue date
June 13, 2003
Implementation date
December 1, 2003
Scope
GB 8058-2003 is the English-translated version of 陶瓷烹调器铅、镉溶出量允许极限和检测方法.
GB 8058-2003 — This Standard specifies the standard permissible limits and testing method for release of lead or cadmium from ceramic cookware. This Standard applies to casserole, boiler, hot pot, wok, heating pot and other kinds of ceramic cooking products in contact with food.
Found what you need?
Document preview — GB 8058-2003
National Standard of the People's Republic of China
- ICS
- 81.060.01
- Classification
- Y20
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Reference standards...4
- 3 Definitions...4
- 4 Permissible limits...5
- 5 Detection methods...5
- 6 Precision...9
- 7 Test report...9
Foreword
Chapter 4 of this Standard is mandatory content, the rest are recommended
content.
This Standard is the revision of GB 8058-1987 "Standard permissible limits and
testing method for release of lead or cadmium from ceramic cookware".
This Standard equivalently adopts international standards ISO 8391-1.1986
"Ceramic cookware in contact with food - Release of lead and cadmium - Part 1.
Method of test" and ISO 8391-2.1983 "Ceramic cookware in contact with food -
Release of lead and cadmium - Part 2. Permissible limits".
This Standard makes the following modifications to the technical content of GB
8058-1937.
- TIGHTEN the permissible limit indicators in Chapter 4;
- DELETE the Chapters 3, 5, 4, 2 of original standard;
- DEFINE more specific provisions about atomic absorption spectrophotometer.
This Standard was proposed by China Light Industry Federation.
This Standard shall be administrated by National Ceramic Standardization
Center.
Drafting organizations of this Standard. Ceramic Research Institute of Light
Industry, Jingdezhen University, and Jingdezhen Ceramic Institute.
Main drafters of this Standard. Shen Wei, Yao Jilie, Chen Benxing, Yu Jinbao,
and Yu Xiaoqin.
This Standard was first released in June 1987.
From the date of implementation of this Standard, it shall replace GB
8058-1987.
Standard permissible limits and testing method for
release of lead or cadmium from ceramic cookware
eqv ISO 8391-1.1986
eqv ISO 8391-2.1986
Replacing GB 8058-1987
1 Scope
This Standard specifies the standard permissible limits and testing method for
release of lead or cadmium from ceramic cookware.
This Standard applies to casserole, boiler, hot pot, wok, heating pot and other
kinds of ceramic cooking products in contact with food.
2 Reference standards
The following standards contain provisions which, through reference in this
Standard, become provisions of this Standard. At time of publication, the
editions indicated are valid. All standards are subject to revision. The parties
who are using this Standard shall explore the possibility of using the latest
version of the following standards.
GB/T 6682-1992 Water for analytical laboratory use - Specification and test
methods (neq ISO 3696. 1987)
3 Definitions
This Standard uses the following definition.
3.1
Ceramic cookware
The ceramic products that are used to heat and prepare food, but excluding
scale. SHAKE it well.
5.3.2 100mg/L of lead standard solution
Accurately TRANSFER 10mL of lead standard solution of which the
concentration is 1000mg/L INTO 100-mL volumetric flask. DELUTE it with 4%
acetic acid solution until it reaches the scale. SHAKE it well.
5.3.3 Series of lead standard solutions
Accurately TRANSFER 0.0, 0.5, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0mL of lead
standard solutions of which the concentration is 100mg/L. And PLACE them in
100-mL volumetric flasks respectively. DELUTE them with 4% acetic acid
solution until they reach the scale. SHAKE well. The solutions contain 0.0, 0.5,
1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0µg lead per milliliter respectively. REPLACE it by
new solutions after being used for 4 weeks.
5.3.4 1000mg/L of cadmium standard solution
WEIGH and TAKE 1.1423g of cadmium oxide which has been baked at
DISSOLVE it with 40mL of glacial acetic acid. COOL it down. MOVE it in
1000-mL volumetric flask. DILUTE it with distilled water until it reaches the
scale. SHAKE it well.
5.3.5 10mg/L of cadmium standard solution
Accurately TRANSFER 10mL of cadmium standard solution of which the
concentration is 1000mg/L INTO 1000-mL volumetric flask. DILUTE it with 4%
acetic acid solution until it reaches the scale. SHAKE it well.
5.3.6 Series of cadmium standard solutions
Accurately TRANSFER 0.00, 0.50, 1.00, 2.00, 3.00, 4.00, 5.00mL of cadmium
standard solutions of which the concentration is 10mg/L. And PLACE them in
100-mL volumetric flasks respectively. DILUTE them with 4% acetic acid
solution until they reach the scale. SHAKE well. The solutions contain 0.00,
0.05, 1.00, 2.00, 3.00, 4.00, 5.00µg cadmium per milliliter respectively.
REPLACE it by new solution after being used for 4 weeks.
from the standard curve directly.
5.5.4.2 Close interpolation method
According to the solution's probable content, TAKE upper-and-lower closely
adjacent standard solution and test sample solution, and COMPARE and
determine at the same time. WRITE down the reading values of absorbance (A)
of each solution for three times or more. TAKE the average value. CALCULATE
by the formula (2).
...(2)
In the formula. C -- Absorbance of lead or cadmium in extract liquor;
A1 -- Absorbance of standard solution with lower concentration;
A2 -- Absorbance of standard solution with higher concentration;
C1 -- Concentration of standard solution with lower concentration, mg/L;
C2 -- Concentration of standard solution with higher concentration, mg/L.
6 Precision
The results of lead shall be accurate to 0.1mg/L;
The results of cadmium shall be accurate to 0.01mg/L.
7 Test report
The test report shall include the following content.
a) Application organization, submission date, inspection nature;
b) Sample's name, serial number, and required inspection items;
c) Name and number of inspection standard;
d) Inspection result;
e) Inspector, inspector's signature, and seal of inspection organization;
f) Reporting date of inspection result;
g) Other explanations relevant to inspection result.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Download GB 8058-2003
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards