Scope
GB 5959.9-2008 is the English-translated version of 电热装置的安全 第9部分:对高频介质加热装置的特殊要求.
GB 5959.9-2008 is the Chinese standard "Safety in electro-heat installations -- Part 9: Particular requirements for high-frequency dielectric heating installations".
Its scope clause reads: GB This part 5959 specifies the personal security device concerning frequency dielectric heating apparatus (hereinafter referred to as a high-frequency dielectric heating apparatus) special requirements.
This section applies to the natural atmosphere and a protective atmosphere (e.g., inert gas or vacuum), and for such as plastic, wood, rubber, woven Portion conductive or nonconductive material products, glass, ceramics, paper, bamboo, and food melting, drying, heat sealing, bonding or the like, and thermal processing pest Industrial high-frequency dielectric heating apparatus. Its clauses include terms and definitions; generator heating medium safeguards.
Found what you need?
Document preview — GB 5959.9-2008
National Standard of the People's Republic of China
- ICS
- 25.180.10
- Classification
- K 60
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 Normative References
- 4 precautions dielectric heating generator
- 4.1 Overview
- 4.2 pairs of direct contact with the protective
- 4.3 Other protective measures
- 4.4 Temperature Rise - Fire
- 4.5 clearance and creepage distances
- 4.6 Internal electrical connections
- 4.7 capacitor
- 4.8 Cooling
- 4.9 Overload
- 4.10 RFI suppression
- 5 uses the applied medium precautions
- 5.1 with a mechanical member moving means
- 5.2 flammable material processing
- 5.3 pairs indirect contact protection
- 5.4 Other protective measures
- 7 Nameplate
- Reference
Foreword
This part of all except art in Chapter 16 of the mandatory content.
GB 5959 "electric safety devices" has the following 13 sections.
--- Part 1. General requirements (GB 5959.1-2005, IEC 60519-1:2003, IDT);
--- Part 2. Particular requirements for arc furnace apparatus (GB 5959.2-2008, IEC 60519-4:2006, IDT);
--- Part 3. Particular requirements for induction and conduction heating apparatus and an induction melting apparatus (GB 5959.3-2008, IEC 60519-3:2005, IDT);
--- Part 4. Particular requirements (GB 5959.4-2008, IEC 60519-2:2006, IDT) resistance heating means;
--- Part 41. Particular requirements for resistance heating means for heating and melting glass --- means (GB 5959.41-2004, IEC 60519-21:1998, IDT);
Safety regulations plasma apparatus (GB 5959.5-1991, eqv IEC 60519-5.. 1980) --- first portion 5;
--- Part 6. Safety Specification Industrial microwave heating apparatus (GB 5959.6-2008, IEC 60519-6:2002, IDT);
--- Part 7. Particular requirements for the apparatus having the electron gun (GB 5959.7-2008, IEC 60519-7:2008, IDT);
--- Part 8. Particular requirements for electroslag remelting furnace (GB 5959.8-2007, IEC 60519-8:2005, IDT);
--- Part 9. Particular requirements (GB 5959.9-2008, IEC 60519-9:2005, IDT) high-frequency dielectric heating apparatus;
--- Part 10. for industrial and commercial heating systems special requirements (IEC 60519-10:2005, to be transformed) resistor profiling;
--- Part 11. electromagnetic stirring of the liquid metal, transport or pouring special requirements (GB 5959.11-2000 device, idt IEC 60519-11:1997);
--- Part 13. Particular requirements for the heating apparatus having an explosive atmosphere (GB 5959.13-2008). This is Part 9 GB 5959's.
This section is equivalent to using IEC 60519-9:2005 "Safety of electric heating means 9. To special high-frequency dielectric heating apparatus Seeking "(second edition, in English).
For ease of use, for IEC 60519-9:2005, made in this section, the following editorial changes.
--- "This standard" be replaced by "this section";
--- deleted international standards foreword and preface;
--- account of the requirements and high-frequency dielectric heating apparatus for the personal protection of the integrated electromechanical equipment, employing
IEC 60519-9:2005, which is extended to the special requirements of the relevant persons and comprising the necessary mechanical safety devices.
This partial replacement GB 5959.9-1989 "Safety of electric equipment Part 9: Particular requirements for high-frequency dielectric heating apparatus", The main technical changes compared with the latter as follows (listed only project name).
--- text "This standard" to "this Part";
--- full article by article number and title of the basic IEC 60519-9:2005 corresponds to revise, write the first chapter 1,2,3 title by GB/T 1.1 Regulations;
--- to increase the range. "Note. Press CISPR11" electromagnetic disturbance characteristics of industrial, scientific and medical (ISM) radio frequency equipment Limits and Method ", specify some preferred primary frequency of ISM (ISM) frequency. ";
--- increased range "GB 5959.1-2005" Safety first portion of the electrothermal device. General Requirements "refers to a segment voltage work Frequency supply voltage. In some circuits in high-frequency dielectric heating apparatus (built-in transformers as generator), DC, or AC Have higher RF voltage values. ";
--- increasing the normative references;
--- delete the original "3.1 to 3.9" 9 terms and definitions;
--- increase "medium heating means 3.1, 3.2 (medium) is applied, a 3.3 standard tools" three terms and definitions;
--- "4.5 clearance and creepage distances" corresponding to the original is deleted in the standard 5.4 "intermediate";
--- "4.6 Internal Electrical connection" after deleting the original corresponding to the standard injection 5.5.2;
--- "4.7 capacitor" Added Note 2, Note 3, 4 content and IEC 60204-1 cited by deleting the reference to the GB 3984;
--- "RFI suppression 4.10" corresponding to the original standard 5.9, 4.10.1 requirements increase;
--- "indirect contact protection 5.3 pairs of" high-frequency voltage without increasing the frequency "heat capacitor or the working electrode is typically only 50Hz/60Hz or DC voltage component (thermal plastic timely prevention apparatus burnt except low pressure). In the event of failure (insulation breakdown Wear), 50Hz/60Hz or DC voltage that may appear on the heating or working electrode of the capacitor. Therefore, it is recommended by a The inductance of the capacitor electrode is grounded or (if there is no such an inductance in the actual circuit). "Claim;
--- 5.4.1 Add "Note. In some cases, when a high-frequency electrode voltage exceeding 10kV magnitude, the arc may be generated (in the electrical heating A surrounding space of the container and the electrode arcing). This arc power capacity of 0.5kW of magnitude, there is usually less than the high frequency With power. Thus, the arc does not cause the overcurrent device operation. To eliminate the arc, there may need to manually cut off and close the high Frequency voltage. ";
6.3 --- increase "manufacturer shall specify the conditions of this test (such as inductors, material and shape of the short-circuit element).";
Increase --- 6.4 "Note. Some devices may reach temperatures member at its maximum load or minimum load actually used value. Therefore, the load test may be necessary. The overload test to find out parasitic oscillation is helpful. ";
--- increase the "References."
This part of the jurisdiction of the National Electric Industry Standardization Technical Committee (SAC/TC121) equipment. This section was drafted. Furnace Co., Ltd. Xi'an Institute.
2 Normative references
Terms of the following documents constitute provisions of this section by reference in this part of GB 5959. For dated references, All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encouraged to reach an agreement under this section Whether the parties to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 2900.23-2008 Electrotechnical term industrial heating means (IEC 60050-841:2004, IDT)
GB 5959.1-2005 electric safety devices - Part 1: General requirements (IEC 60519-1:2003, IDT)
3 Terms and Definitions
GB/T 2900.23-2008 and GB 5959.1-2005 established following terms and definitions apply to this section.
3.3 Screwdriver, adjustable wrench, flat wrenches and pliers and other simple tools
3.1
It means consisting of a dielectric and the dielectric heating applicator generator, high frequency transmission line (if any).
3.2 Or by the heating of the capacitor fixing and positioning system with a working electrode, an impedance matching circuit (if it is not disposed in the generator), the need
Protection and shielding means and transfer means, the supply and ventilation thereof.
4 Generator heating medium safeguards
4.10.1 RF interference should be avoided during normal operation of the heating medium.
A housing containing a high-frequency circuit section 4.10.2 pair shall be constructed so that leakage of high-frequency radiation is minimized. Doors and covers of the housing should have Electromagnetic shielding function.
4.10.3 When applying dielectric heating generator and does not fit together, the connection between them to deal with the high frequency to be shielded.
4.10.4 high frequency generator part for maintenance, observation and ventilation openings, should provide adequate protection, the high-frequency radiation exposure Minimized.
4.10.5 if necessary, all the power and control circuits for the high-frequency generator, filtering means shall be provided to ensure that it does not exceed the grid disturbance Over the limit.
4.10.6 prevent radiation interference of high frequency electromagnetic field in the metal conduit or shield, inductively small wire guide them Electrically connected to the housing.
4.1 Overview
Dielectric heating generator comprising.
a) a portion of the frequency components of the power supply and distribution required;
b) a rectifier section, which typically includes the commercial frequency current into a high voltage direct current component;
c) oscillator section, and which comprises generating high frequency energy necessary for matching element (oscillator section housed within a high frequency shield to reduce radiation);
d) control and monitoring system, which comprises a program controller for interlocking the overload safety device and a switching means and monitoring Device.
4.2 Pairs of direct contact with the protective
4.2.1 General Protection
In addition to dielectric heating generator output terminal, all the live parts to be provided in one or more adequate for protection against direct contact With the housing.
4.2.2 Protective measures close to the second section of the charging voltage portion
For accessing the second section of the door voltage (up to 1500V 1000V AC or smoothed DC) charging section and/or removable cover Plate, should be provided with a key to open the door or configuration, when the door is open or remove the cover interlock can cut off electrical power.
Rarely open to the removable cover should be fastened with screws secure the safety screw without tools or with standard tools that they can not Remove the.
4.2.3 Proximity third segment voltage charging portion safeguards
Used for access to the third segment voltage (over 1500V 1000V AC or smoothed DC) portion of the charging door and/or removable cover Plate, mechanical interlock shall be provided with a power measures to prevent the electrode portion closer to the charging voltage is removed prior to, or at the same time an electrical configuration of the door Gas interlock and mechanical locks.
Rarely open to the removable cover should be fastened with screws secure the safety screw without tools or with standard tools that they can not Remove the.
4.2.4 Protective measures in the proximity of the high-frequency voltage charging section
In the case where only the live parts may be close at a high frequency voltage (not close in a 50Hz/60Hz frequency voltage of lower frequency, such as Live parts), should take the following precautions.
Except when the foreign matter does not enter the high-frequency component while in contact with the protective housing of the door or the protective cover or housing to provide comprehensive and effective An outer protection, the protective shell of the movable cover or door openings to be provided and reliability can not be reset or non-reset of the safety switch Interlock means to ensure that when a high frequency voltage is not applied when the door is open or remove the cover plate.
Few of the open cover removably screwing security applications, the security screw with standard tools without tools or from outside it is not They were relieved of.
4.2.5 Warning labels
It should set the necessary warning signs.
NOTE: In some countries, the need to set up warning signs to inform non-ionizing radiation with a marker.
4.3 Other protective measures
4.3.1 Protection device should have the following means.
a) should be provided with one or more means to protect the under abnormal operating conditions (e.g., during the overload condition) it from damage Means;
b) if necessary, be provided with one or more of the present apparatus so as to protect the device from interference of other devices;
c) if necessary, it is provided with one or more means of the present apparatus so as to protect against interference autogenous.
4.3.2 If necessary, each of the protection device shall be jointly overtemperature protection.
4.3.3 shall take appropriate measures to reduce the induced voltage or induced current so that it meets safety standards.
4.3.4 All armored cable and the metal feed pipe, in through the high-voltage circuit contains a voltage belonging to the third segment of the housing, they should be Grounded through the housing.
4.3.5 DC power and 50Hz/60Hz frequency AC power station apparatus, the grounding should meet the requirements of GB 5959.1-2005.
Means for transmitting high-frequency power apparatus should be protected to ensure that the voltage at the contacts where the operator is allowed value, for example with a ground The shield and/or an operator located at the ground.
4.4 Temperature Rise - Fire
4.4.1 dielectric heating generator and a rectifier, the circuit should be arranged so that they are subjected to neither high temperature nor in the cabinet housing so that they The temperature generated electrical device generally exceeds the allowed values.
4.4.2 material for the high-frequency voltage component to be free of any component will produce sustained combustion.
4.4.3 When the temperature rise within the cooling circuit fault of the generator will exceed the allowable value, the monitoring device should be provided for the power supply of the cutting device Or take other measures to ensure safety.
4.5 Clearance and creepage distances
A high frequency device used in the air gap and creepage distance are not necessarily identical 50Hz/60Hz frequency and means.
When small air gaps and creepage distances (e.g., high-frequency circuits), measures should be taken to prevent arcing to ensure safety.
4.6 Internal electrical connections
4.6.1 high-frequency current conductor and the connection means should be non-ferromagnetic material, it should also cover non-ferromagnetic material.
4.6.2 should be protected all the low frequency circuit, in order from the effects of high frequency of, for example, configure one or more high-frequency filter.
4.7 Capacitor
4.7.1 Unless the capacitor device and other electrical equipment in direct contact with the discharge path and the discharge path does not access the disconnecting Off fuse or the series capacitor, to ensure safety, the capacitor device belonging to respond to the second and third segments direct voltage even when necessary Contact discharge device.
Note 1. discharge means can not be used a short-circuit between the capacitor and staff to ground before the respective terminal contact of the capacitor.
Note 2. IEC 60204-12) 6.2.4 frequency of the power supply and control circuit measures the residual voltage protection means carries electrical charge of equal or greater than 60µC container.
Note 3. The high-voltage capacitor circuit in the vast majority of the charge carried by much less than 60µC, according to the article discharge device may be omitted.
Note 4. high voltage power supply filter capacitor some charges may exceed this value, then the article precautions apply.
2) Description adopt standard. GB 5226.1-2002 Safety of machinery Electrical Equipment Part 1: Common technical (current valid version) (IEC 60204-1:2000, IDT).
When using high-voltage power 4.7.2 LC filter when the energy conversion element (such as a tube or a semiconductor device), a vibrator should be provided if necessary, Oscillation damping means to prevent over-voltage disconnect the circuit exceed the allowable value.
4.8 Cooling
4.8.1 water cooling members, appropriate measures should be taken to limit the electrolytic corrosion interfere with normal operation. For this reason, the manufacturer should be provided with means Suitable instructions for use.
4.8.2 Soft water and its layout should make the leak current does not exceed safe levels.
NOTE: In the cooling system should try to avoid the formation of bubbles. Hose fittings require special attention.
4.8.3 In the water-cooled conductor passing high-frequency current, to avoid water condensation.
4.8.4 of forced air-cooled medium heat generator, precautions should be taken to prevent and reduce the deposition of dust due to the safety of the operation.
4.9 Overload
4.9.1 circuits and components for dielectric heating generator, if the temperature exceeds the allowable value, should provide thermal overload protection.
4.9.2 short-circuit may occur in all parts of the device caused by the overload protection should be provided.
4.9.3 If necessary, the medium is heated generator should be provided with a program control device, in order to ensure personal power down under abnormal operating conditions, and Safety device.
4.9.4 If the charge processing device for heating the medium located outside the generator should be provided with a remote connection terminal, should be provided for at least Operation "Emergency Stop" connected terminal device. RFI suppression 4.10
Note: the provisions concerning radio frequency disturbance limits in the CISPR11.
5 Application of protective measures in the use medium
5.1 with a mechanical member moving means
5.1.1 Application of these devices be protected against a fence or similar protective facilities, the hand of the staff can not projecting therein. When these anti Care facilities when they are "safe" location away from all moving parts of the machine should be stopped. Fixed protection facilities, the key will be available only It moved.
These safeguards do not apply to operations during normal operation conducted by the staff.
5.1.2 in a suitable case, can also be used instead of electronic or electrical protection device mechanically; and when any failure of a guard and can be When can endanger personal safety, you should stop all mechanical movements.
5.1.3 should be taken to ensure that the internal temperature under normal operating conditions of the operating area may exceed 60 °C all parts be protected, to Free staff access; or striking marked indicia on these parts.
5.1.4 Ruoyi provide suitable protective measures for all but certain moving parts (conveyor belt) potentially hazardous operation because the device Reasons it can not be guarded, are advised to set up conspicuous warning.
5.1.5 In order to comply with the relevant provisions of the country in the use of power-operated press, precautions should be taken so that the operator is in operation Can not contact with the dangerous moving parts.
5.2 Flammable materials processing
In dealing with flammable materials, should take special precautions.
5.3 Pairs indirect contact protection
High-frequency radiation not induced any case when the operator endanger personal contact therewith on the outside of the shield member or housing Security of voltage or current.
Heating the capacitor or only the working electrode is typically a high frequency voltage without frequency 50Hz/60Hz or DC voltage component (thermal plastic Preventing burn-off means except when a low pressure). When a failure (insulation breakdown) occurs, 50Hz/60Hz or DC voltage may occur in the electrical heating The container or on the working electrode. Accordingly, the adoption of an inductor (if no such inductance in the actual circuit) or the electrodes of the capacitor Ground.
5.4 Other protective measures
5.4.1 normal operation is unlikely to occur flashover should be given adequate attention.
Note: In some cases, when a high-frequency electrode voltage exceeding 10kV magnitude, the arc may be generated (flying in a space around the heating electrode of the capacitor arc). This arc power capacity of 0.5kW of magnitude, typically less than the high frequency useful power. Thus, the arc does not cause the overcurrent device operation. for The elimination of the arc, it may be necessary to manually cut off and close the high frequency voltage.
5.4.2 Design of the insulating support member should take full account of its tensile and compressive strength as well as temperature and electrical voltage withstanding property.
5.4.3 shall mechanical parts in high-frequency electromagnetic field to be under protection, the induced current generated neither they nor damage Movies Ring their normal function.
5.4.4 Commutation overflowing liquid material for high-frequency treatment apparatus suitable size should be provided isopipe.
5.4.5 is exposed to the high frequency electromagnetic field should be appropriately shielded electrical conduits.
5.4.6 All metal parts should be applied to an internal charge antistatic protection.
5.4.7 device located outside the shielding metal member was appropriately combined together as far as possible, to prevent local excessive temperature rise and/or too strong High-frequency interference.
High-frequency radiation in the place in which the strength of the operator 5.4.8 shall comply with the national country of the apparatus used (see GB 5959.1-2005)
Note: The circumstances of RF harassment, see 4.10. Test 6 protective measures
6.1 Test procedure should be considered and should be checked for all protective measures in each case to ensure the safety of the operator.
6.2 pairs accessible during normal use high-frequency circuit, the temperature should not exceed 150 °C. This can be an appropriate way to check.
6.3 should be accessible or heating the working electrode of the capacitor short circuit. Dielectric heating power generator is set at a maximum value, Or operator of the apparatus should be no harm or danger (e.g. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 1 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2900.23-2008 · GB 5959.1-2005
How to Download GB 5959.9-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 5959.13-2008 — Safety in electroheat installations - Part 13: particular requirements for electroheat installation with explosive atmosphere
GB 5959.2-2008 — Safety in electro-heat installations -- Part 2: Particular requirements for arc furnace installations
GB 5959.3-2008 — Safety in electro-heat installations -- Part 3: Particular requirements for induction and conduction heating and induction melting installations
Secure payment via Stripe
Payments accepted
GB 5959.9-2008
$105.00