GB 5126-1982Eddy current inspection method for cold drawn thin wall tubes of aluminum and aluminum alloy (English PDF)
This is a limited preview
Buy now to download the full PDF (8 pages)
Need quotation for your management?
Get a formal quotation for GB 5126-1982 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
GB 5126-1982 (Eddy current inspection method for cold drawn thin wall tubes of aluminum and aluminum alloy) is available as an English-translated PDF.
GB 5126-1982 — This standard specifies the aluminum and aluminum alloy cold-drawn thin-walled tubes encircling eddy current testing methods outlined and testing personnel, the environment, equipment and materials and Contents of sample preparation, detection requirements and test records, test reports.
This standard applies to an outer diameter of 6mm ~ 40mm, wall thickness of 0.5mm ~ 1.8mm high pressure air duct, common duct and general Aluminum and aluminum alloy seamless tube testing purposes.
Found what you need?
Document preview — GB 5126-1982
National Standard of the People's Republic of China
- ICS
- 77.040.20
- Classification
- H 26
- Replacing
- GB/T 5126-2001
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative reference standard
- 3 Terms
- 4 Summary of Method
- 5 Inspectors
- 6 Detects the environment
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GB/T 5126-2001 "aluminum and aluminum alloy cold-drawn thin-walled pipe eddy current testing method." this standard compared with GB/T 5126-2001, the main differences are as follows.
--- In the original standard, based on the increase in the detection size;
--- Comparative sample tube to the requirements of the supplementary provisions;
--- Of artificial defect size acceptance criteria have been revised;
--- Evaluation of the test results have been revised;
--- Detection procedures supplementary provisions;
--- This standard increases the acceptance level;
--- This term refers to the standard GB/T 12604 "Terminology for nondestructive testing eddy current testing." the standard reference method using redrafted ASTME215-2011 "calibration method of seamless aluminum alloy pipe electromagnetic inspection equipment" Program System, and the degree of consistency equivalent non ASTME215-2011.
This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized.
This standard is mainly drafted by. Northeast Light Alloy Co., Ltd., Suzhou Chun-NDT Equipment Co., Ltd., Beijing Nonferrous Metal Research Institute, Southwest Aluminum (Group) Co., Ltd., China Aluminum Industry Branch of Northwest Aluminum, high-tech light wire Zhejiang East Co., Ltd., State Nonferrous Metals Industry Nondestructive Testing Center, Guangzhou Nonferrous Metal Research Institute, Shandong Yankuang Light Alloy Co., Ltd.
1 Scope
This standard specifies the aluminum and aluminum alloy cold-drawn thin-walled tubes encircling eddy current testing methods outlined and testing personnel, the environment, equipment and materials and Contents of sample preparation, detection requirements and test records, test reports.
This standard applies to an outer diameter of 6mm ~ 40mm, wall thickness of 0.5mm ~ 1.8mm high pressure air duct, common duct and general Aluminum and aluminum alloy seamless tube testing purposes.
2 Normative reference standard
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 9445 NDT personnel qualification and certification GB/T 12604.6 Terminology for nondestructive testing Eddy current testing
3 Terms
Terms and definitions GB/T 12604.6 defined apply to this document.
4 Summary of Method
When the subject through the concentric pipe through an alternating current probe (detection coil) when the subject is generated pipe surface and near surface induced eddy currents, and Eddy current induced magnetic field generated by such factors as the subject pipe geometry, conductivity, permeability, stress, metallurgical and mechanical defects and other changes Change. Signal is transmitted to the probe will change detector, the detector signal change through amplification, processing, extracting the desired conversions to the defect signal to the timing display, vector display form on the display. The comparative sample tube defect signal and the reflected artificial defects Signals are compared to assess the quality of the subject tubing.
5 Inspectors
5.1 in Eddy Current Testing personnel should meet the GB/T 9445 requirements.
5.2 Eddy Current Testing personnel only engage corresponding technical work with their technical level qualifications.
6 Detects the environment
6.1 detected near the site should not affect the normal work equipment magnetic, vibration, corrosive atmosphere, and other confounding factors.
6.2 Detection venue temperature and relative humidity should be controlled within the allowable range of equipment.
6.3 detection sites should be clean, ventilated workspace without affecting the correct operation of the eddy current testing personnel, test results assessed as principle.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.
How to Download GB 5126-1982
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 5126-1982
$254.00