Scope
GB 5009.267-2020 (National food safety standard - Determination of iodine in foods) is available as an English-translated PDF.
GB 5009.267-2020 — This standard specifies the determination method of iodine content in food. The method 1 Inductively coupled plasma mass spectrometry is suitable for the determination of iodine in food. The method 2 Redox titration is suitable for the determination of iodine in algae and its products. The method 3 Arsenic-cerium catalytic spectrophotometry is suitable for the determination of iodine in food, vegetables, fruits, beans and their products, milk and their products, meat, fish and eggs. The method 4 Gas chromatography is applicable to the determination of nutritional fortifier iodine in infant formula foods and dairy products (except infant formula foods for special medical purposes and formula foods for special medical purposes). Method 1 -- Inductively coupled plasma mass spectrometry (ICP-MS)
Document preview — GB 5009.267-2020
National Standard of the People's Republic of China
Issued by: National Health Commission and State Administration for Market Regulation
Contents
- Foreword4
- 1 Scope5
- 2 Principle5
- 3 Reagents and materials6
- 4 Instruments and equipment7
- 5 Analytical procedures7
- 6 Expression of analysis results9
- 7 Precision10
- 8 Others10
- 9 Principle10
- 10 Reagents and materials11
- 11 Instruments and equipment12
- 12 Analytical procedures13
- 13 Expression of analysis results13
- 14 Precision14
- 15 Others14
- 16 Principles14
- 17 Reagents and materials15
- 18 Instruments and equipment16
- 19 Analytical procedures17
- 20 Expression of analysis results18
- 21 Precision18
- 22 Others19
- 23 Principles19
- 24 Reagents and materials19
- 25 Instruments and equipment20
- 26 Analytical procedures20
- 27 Expression of analysis results22
- 28 Precision23
- 29 Others23
- Appendix A Gas chromatogram of iodine standard derivative24
1 Scope
This standard specifies the determination method of iodine content in food.
The method 1 Inductively coupled plasma mass spectrometry is suitable for the determination of iodine in food.
The method 2 Redox titration is suitable for the determination of iodine in algae and its products.
The method 3 Arsenic-cerium catalytic spectrophotometry is suitable for the determination of iodine in food, vegetables, fruits, beans and their products, milk and their products, meat, fish and eggs.
The method 4 Gas chromatography is applicable to the determination of nutritional fortifier iodine in infant formula foods and dairy products (except infant formula foods for special medical purposes and formula foods for special medical purposes).
Method 1 -- Inductively coupled plasma mass spectrometry (ICP-MS)
2 Principle
The iodine in the specimen is extracted by tetramethylammonium hydroxide solution and measured by inductively coupled plasma mass spectrometer. It is qualitatively determined by the specific mass of iodine element 127 (mass-to-charge ratio, m/z), the mass spectrometry signal intensity ratio between iodine element and internal standard element which is proportional to the concentration of the iodine element is used for quantification, to determine the iodine content in the specimen.
3 Reagents and materials
Unless otherwise specified, the reagents used in this method are all premium-grade pure water; the water is the grade 1 water as specified in GB/T 6682 or the high-purity water used for instrument analysis as specified in GB/T 33087-2016.
3.1 Reagent
3.1.1 25% Tetramethylammonium hydroxide [(CH3)4NOH] aqueous solution.
the English abbreviation name TMAH.
3.1.2 Isopropanol. Chromatographically pure.
3.1.3 Argon (Ar). Argon (>= 99.995%) or liquid argon.
3.1.4 Helium (He). Helium (>= 99.995%).
3.2 Preparation of reagents
3.3 Standard product
Potassium iodide (KI) or potassium iodate (KIO3). Reference reagent.
3.4 Preparation of standard solution
3.4.1 Iodine standard stock solution (1000 mg/L). Weigh 0.1685 g of potassium
iodate that has been dried at 180 °C +/- 2 °C to a constant weight. Use water to dissolve and make its volume reach to 100 mL. Or weigh 0.1307 g of potassium iodide which had been dried in a silica gel dryer for 24 hours. Use water to dissolve and dilute it to 100 mL. Store it in a brown bottle. It may also use the iodine standard solution certified nationally and awarded with a certificate of standard material.
3.4.2 Iodine standard intermediate solution (10.0 mg/L). Pipette 1.00 mL of
iodine element standard stock solution. Use diluent to make its volume reach to 100 mL.
3.4.3 Iodine standard solution (100 ug/L). Pipette 1.00 mL of iodine element
standard intermediate solution. Use diluent to make its volume reach to 100 mL.
3.4.6 Internal standard solution. First use water to dilute the internal standard
element standard solution 10 times or 100 times. Then take an appropriate amount of the solution and use the diluent to prepare an internal standard solution of appropriate concentration.
4 Instruments and equipment
4.1 Inductively coupled plasma mass spectrometer (ICP-MS).
4.2 Analytical balance. Sensitivity is 0.1 mg and 1 mg.
4.3 Constant temperature drying oven or constant temperature water bath shaker.
4.6 Vortex mixer.
5 Analytical procedures
5.1 Preparation of specimen
5.1.1 Solid samples
5.1.1.1 Dry sample
For samples of beans, grains, fungi, tea, dried fruits, baked foods, etc., take the edible part; use a high-speed grinder to crush it; stir until uniform. For solid dairy products, protein powders, flour and other homogeneous powder samples, shake it uniformly.
5.1.1.2 Fresh sample
Wash and drain samples of vegetables, fruits, aquatic products, etc., if necessary; homogenize the edible part. For samples of meat and eggs, homogenize the edible part.
5.1.1.3 Quick frozen and canned food
Homogenize the edible part of the thawed quick-frozen food and canned food samples to homogeneity.
5.1.2 Liquid sample
Shake the samples of soft drinks, condiments, etc., uniformly.
5.2 Specimen processing
Weigh 0.2 g ~ 1 g (accurate to 0.001 g) of the specimen in a 50 mL plastic centrifuge tube which is resistant to 110 °C temperature. Add 5 mL of extraction solution. Vortex for 1 min, to make the sample fully dispersed.
5.3 Instrument reference conditions
5.3.1 Reference working conditions for instrument operation
Radio frequency power 1550 W; plasma gas flow rate 15 L/min; carrier gas flow rate 0.80 L/min ~ 0.90 L/min; auxiliary gas flow rate 0.30 L/min ~ 0.40 L/min;
pump speed during analysis.
5.3.2 Measurement reference conditions
After the tuning instrument meets the measurement requirements, edit the measurement method and select the iodine isotope (127I) and the internal standard tellurium isotope (125Te, 130Te) or 103Rh or 115In or 185Re.
5.4 Preparation of standard curve
Inject iodine standard solution into ICP-MS. Measure the signal response value of iodine element and internal standard element. Take the mass concentration of iodine element as the abscissa, the ratio of the response signal value of iodine element and the selected internal standard element as the ordinate, to draw standard curve.
5.5 Measurement of sample solution
Inject the blank and sample solution into the inductively coupled plasma mass spectrometer, respectively. Measure the signal response values of the iodine element and the selected internal standard element. Calculate the ratio of the response signal value of the iodine element and the selected internal standard element.
6 Expression of analysis results
The iodine content in the specimen is calculated according to formula (1).
7 Precision
When the iodine content in the sample is greater than 1 mg/kg, the absolute difference between the two independent determination results obtained under repeatability conditions shall not exceed 10% of the arithmetic mean. When it is less than or equal to 1 mg/kg and greater than 0.1 mg/kg, the absolute difference between two independent determination results obtained under repeatability conditions shall not exceed 15% of the arithmetic mean.
8 Others
Calculated with a sampling volume of 0.5 g and a constant volume to 50 mL, the detection limit of the method is 0.01 mg/kg; the limit of quantification is 0.03 mg/kg.
9 Principle
After the sample is carbonized and ashed, in an acidic medium, liquid bromine is used to oxidize iodide ions into iodate ions. The iodate oxidizes potassium iodide in the acidic solution to precipitate iodine.
10 Reagents and materials
Unless otherwise specified, the reagents used in this method are all analytically pure; the water is grade-3 water as specified in GB/T 6682.
10.1 Reagents
10.1.1 Anhydrous sodium carbonate (Na2CO3).
10.1.2 Liquid bromine (Br2).
10.1.3 Sulfuric acid (H2SO4).
10.1.4 Sodium formate (CHNaO2).
10.1.5 Sodium thiosulfate (Na2S2O3 - 5H2O).
10.1.6 Potassium iodide (KI). Reference substance.
10.1.7 Methyl orange.
10.1.8 Soluble starch.
10.2 Reagent preparation
10.2.1 Sodium carbonate solution (50 g/L). Weigh 5 g of anhydrous sodium
carbonate. Use water to dissolve it and make its volume reach to 100 mL.
10.2.2 Saturated bromine water.
10.2.6 Sodium formate solution (200 g/L). Weigh 20.0 g of sodium formate. Use
water to dissolve and dilute it to 100 mL.
10.3 Preparation of standard solution
10.3.1 Standard stock solution of sodium thiosulfate (0.1 mol/L). Weigh 26 g of
sodium thiosulfate (Na2S2O3 - 5H2O). Add 0.2 g of anhydrous sodium carbonate.
Dissolve it in 1000 mL water. Slowly boil it for 10 min. Cool it down. Filter and calibrate after being placed for two weeks.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Buy GB 5009.267-2020
- 1Add to cart. Click the "Buy GB 5009.267-2020" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 5009.1-2025 — National food safety standard - Physical and chemical testing - General principles