GB 5009.248-2016 is the English-translated version of 食品安全国家标准 食品中叶黄素的测定.
GB 5009.248-2016 — This Standard specifies the liquid chromatography for the determination of lutein in foods. This Standard applies to liquid chromatography determination of lutein in infant formula, dairy products, frozen drinks, rice and flour products, bakery products, jams, jellies, and beverages.
Found what you need?
Document preview — GB 5009.248-2016
National Standard of the People's Republic of China
Issued by: National Health and Family Planning Commission of the PRC
Contents
- Foreword...3
- 1 Scope...4
- 2 Principles...4
- 3 Reagents and materials...4
- 4 Instruments and equipment...6
- 5 Analytical procedures...6
- 6 Analysis results expression...9
- 7 Precision...9
- 8 Other...9
- Appendix A Method for correction of standard solution concentration...11
- Appendix B Liquid chromatogram of standard solution...12
Foreword
This Standard replaces GB/T 23209-2008 "Determination of lutein in milk
powder - HPLC-UV method".
As compared with GB/T 23209-2008, the main changes of this Standard are as
follows.
- CHANGE the standard's name to "National Food Safety Standard -
Determination of lutein in foods";
- EXPAND the scope of application; ADD the liquid chromatography for the
determination of lutein in frozen drinks, rice and flour products, bakery
products, jams, jellies, and beverages;
- MODIFY the "Principles" of the former standard. The former "USE acetone
as a solvent to extract" is changed to "USE diethyl ether-n-hexane-
cyclohexane solvent system to extract";
- ADD the points worthy of notice for the operation process;
- ADD a saponification step for samples with high fat content including milk
powder; and PROVIDE different pretreatment methods to accommodate
various sample matrix analysis needs;
- ADD the correction requirement for the concentration of lutein standard
solution;
- For the phenomenon that lutein may be isomerized during the test operation,
ADD the qualitative and quantitative requirements for cis-lutein produced
due to isomerization.
National Food Safety Standard -
Determination of lutein in foods
1 Scope
This Standard specifies the liquid chromatography for the determination of
lutein in foods.
This Standard applies to liquid chromatography determination of lutein in infant
formula, dairy products, frozen drinks, rice and flour products, bakery products,
jams, jellies, and beverages.
2 Principles
After foods with high fat content (fat content of not less than 3% on a dry basis)
are saponified with potassium hydroxide solution at room temperature to free
lutein, then USE diethyl ether-n-hexane-cyclohexane (40+40+20, volume ratio)
to extract; USE liquid chromatography to separate; USE UV-detector or diode
array detector to detect; and USE external standard method for quantification.
Lutein in the samples of the other foods is directly extracted by diethyl ether-n-
hexane-cyclohexane (40+40+20, volume ratio). After the extract is purified by a
neutral alumina solid phase extraction cartridge, USE liquid chromatography to
separate; USE UV-detector or diode array detector to detect; and USE external
standard method for quantification.
3 Reagents and materials
Unless otherwise stated, the reagents used in this method are of analytically
pure; the water is Grade I water specified in GB/T 6682.
3.1 Reagents
3.1.1 Cyclohexane (C6H12). chromatographically pure.
3.1.2 Diethyl ether [(C2H5)2O]. chromatographically pure.
3.1.7 Potassium hydroxide (KOH).
3.1.8 Iodine (I2).
3.2 Preparation of reagents
3.2.1 10% potassium hydroxide solution. WEIGH 10 g of potassium hydroxide
(3.1.7); ADD water to dissolve and dilute to 100 mL.
3.2.2 20% potassium hydroxide solution. WEIGH 20 g of potassium hydroxide
(3.1.7); ADD water to dissolve and dilute to 100 mL.
3.2.3 Extraction solvent. WEIGH 1 g of BHT (3.1.6); USE 200 mL of
cyclohexane (3.1.1) to dissolve; ADD 400 mL of diethyl ether (3.1.2) and 400
mL of n-hexane (3.1.3), and MIX well.
3.3 Standard
Lutein (CAS number. 127-40-2), with a purity of not less than 98.0%.
3.4 Preparation of standard solutions
3.4.1 Standard stock solution (50 µg/mL). Accurately WEIGH 5 mg (accurate to
0.01 mg) of lutein (3.1.3); USE 0.1% BHT ethanol solution (3.2.4) to dissolve
and dilute to 100 mL. This standard stock solution can be stored for six months
by filling nitrogen and avoiding light in a refrigerator of -20 °C or below.
3.4.2 Standard working solutions. accurately PIPETTE 0.050 mL, 0.100 mL,
0.200 mL, 0.400 mL, 1.00 mL of standard stock solution of lutein (3.4.1) into 5
25 mL brown volumetric flasks; USE 0.1% BHT ethanol solution (3.2.4) to dilute
to volume; and OBTAIN a series of standard working solutions having
concentrations of 0.100 µg/mL, 0.200 µg/mL, 0.400 µg/mL, 0.800 µg/mL, and
2.00 µg/mL.
4 Instruments and equipment
4.1 Liquid chromatograph, with diode array detector or UV-detector.
4.2 UV-visible spectrophotometer.
4.3 Analytical balance. The sensitivity is 0.01 mg and 0.01 g.
4.7 Decompression concentrator.
4.8 Solid phase extraction plant.
4.9 Centrifuge. The speed is not less than 4500 r/min.
5 Analytical procedures
Note. Because lutein is sensitive to light, unless otherwise stated, all test operations shall
be performed in a yellow or red light source environment with no UV light below 500
nm.
5.1 Sample preparation
A certain number of samples are pulverized, homogenized, and divided as
required, and stored in a sample bottle. The prepared sample shall be filled with
nitrogen and sealed; and stored in a refrigerator at -20 °C or below.
5.2 Extraction
5.2.1 Foods with high fat content (such as infant formula, milk powder, ice
cream, bakery nuts, etc.)
5.3 Instrument reference conditions
5.3.1 Chromatographic column. C30 column, 5 µm, 250 mm×4.6 mm (inner
diameter) or equivalent;
5.3.2 Column temperature. 30 °C;
5.3.3 Mobile phase. methanol/water (88+12, volume ratio, containing 0.1%
BHT)-methyl tert-butyl ether (containing 0.1% BHT), gradient elution. 0 min~18
min, methanol/water is changed from 100% to 10%; 18.1 min, methanol/water
is changed from 10% to 100%, retained for 10 min;
5.4 Making of standard curve
The series of standard working solutions are separately injected into the liquid
chromatograph, to determine the corresponding peak area. USE the
concentration of standard working solution as the abscissa. USE the peak area
as the ordinate. The standard curve is drawn.
5.5 Determination of sample solution
The response value of lutein in the sample solution to be determined shall be
within the linear response range of the instrument, otherwise it shall be diluted
or concentrated appropriately.
6 Analysis results expression
The content of lutein in the sample shall be calculated according to formula (1).
7 Precision
The absolute difference between the two independent determination results,
obtained under repeated conditions, shall not exceed 15% of the arithmetic
mean.
8 Other
The detection limit of this method. For infant formula, milk powder, ice cream,
bakery nuts, and other foods, when the sampling amount is 2 g and the constant
volume is 5 mL, the detection limit is 3 µg/100 g. For liquid milk, etc., when the
sampling amount is 10 g and the constant volume is 25 mL, the detection limit
is 3 µg/100 g. For rice and flour products, jams, and other foods, when the
sampling amount is 5 g and the constant volume is 10 mL, the detection limit is
3 µg/100 g.
Appendix A
Method for correction of standard solution concentration
The lutein standard solution, after preparation, needs to be calibrated. TAKE 1
mL of standard stock solution; USE ethanol to dilute to 25 mL. PIPETTE this
solution into a 1 cm quartz cuvette. USE ethanol as a blank; USE a
spectrophotometer, under a wavelength of 445 nm, to determine the
absorbance A. According to formula (A.1), calculate the standard solution
concentration.
Appendix B
Liquid chromatogram of standard solution
B.1 Liquid chromatogram of lutein (trans) standard solution
The liquid chromatogram of lutein (trans) standard solution is shown in Figure
B.1.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
How to Download GB 5009.248-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 5009.1-2025 — National food safety standard - Physical and chemical testing - General principles
GB 5009.11-2024 — National food safety standard - Determination of total arsenic and inorganic arsenic in food
GB 5009.111-2016 — National food safety standard - Determination of deoxynivalenol and its acetylated derivatives in food
Secure payment via Stripe
Payments accepted
GB 5009.248-2016
$55.00