Valid

GB 5009.248-2016National food safety standard - Determination of lutein in foods (English PDF)

食品安全国家标准 食品中叶黄素的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for GB 5009.248-2016 in 30 minutes.

Issued by

National Health and Family Planning Commission of the PRC

Level / Type

National · Mandatory

Issue date

August 31, 2016

Implementation date

March 1, 2017

Scope

GB 5009.248-2016 is the English-translated version of 食品安全国家标准 食品中叶黄素的测定.

GB 5009.248-2016 — This Standard specifies the liquid chromatography for the determination of lutein in foods. This Standard applies to liquid chromatography determination of lutein in infant formula, dairy products, frozen drinks, rice and flour products, bakery products, jams, jellies, and beverages.

Found what you need?

Document preview — GB 5009.248-2016

National Standard of the People's Republic of China

Issued by: National Health and Family Planning Commission of the PRC

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Principles...4
  • 3 Reagents and materials...4
  • 4 Instruments and equipment...6
  • 5 Analytical procedures...6
  • 6 Analysis results expression...9
  • 7 Precision...9
  • 8 Other...9
  • Appendix A Method for correction of standard solution concentration...11
  • Appendix B Liquid chromatogram of standard solution...12

Foreword

This Standard replaces GB/T 23209-2008 "Determination of lutein in milk

powder - HPLC-UV method".

As compared with GB/T 23209-2008, the main changes of this Standard are as

follows.

- CHANGE the standard's name to "National Food Safety Standard -

Determination of lutein in foods";

- EXPAND the scope of application; ADD the liquid chromatography for the

determination of lutein in frozen drinks, rice and flour products, bakery

products, jams, jellies, and beverages;

- MODIFY the "Principles" of the former standard. The former "USE acetone

as a solvent to extract" is changed to "USE diethyl ether-n-hexane-

cyclohexane solvent system to extract";

- ADD the points worthy of notice for the operation process;

- ADD a saponification step for samples with high fat content including milk

powder; and PROVIDE different pretreatment methods to accommodate

various sample matrix analysis needs;

- ADD the correction requirement for the concentration of lutein standard

solution;

- For the phenomenon that lutein may be isomerized during the test operation,

ADD the qualitative and quantitative requirements for cis-lutein produced

due to isomerization.

National Food Safety Standard -

Determination of lutein in foods

1 Scope

This Standard specifies the liquid chromatography for the determination of

lutein in foods.

This Standard applies to liquid chromatography determination of lutein in infant

formula, dairy products, frozen drinks, rice and flour products, bakery products,

jams, jellies, and beverages.

2 Principles

After foods with high fat content (fat content of not less than 3% on a dry basis)

are saponified with potassium hydroxide solution at room temperature to free

lutein, then USE diethyl ether-n-hexane-cyclohexane (40+40+20, volume ratio)

to extract; USE liquid chromatography to separate; USE UV-detector or diode

array detector to detect; and USE external standard method for quantification.

Lutein in the samples of the other foods is directly extracted by diethyl ether-n-

hexane-cyclohexane (40+40+20, volume ratio). After the extract is purified by a

neutral alumina solid phase extraction cartridge, USE liquid chromatography to

separate; USE UV-detector or diode array detector to detect; and USE external

standard method for quantification.

3 Reagents and materials

Unless otherwise stated, the reagents used in this method are of analytically

pure; the water is Grade I water specified in GB/T 6682.

3.1 Reagents

3.1.1 Cyclohexane (C6H12). chromatographically pure.
3.1.2 Diethyl ether [(C2H5)2O]. chromatographically pure.
3.1.7 Potassium hydroxide (KOH).
3.1.8 Iodine (I2).

3.2 Preparation of reagents

3.2.1 10% potassium hydroxide solution. WEIGH 10 g of potassium hydroxide

(3.1.7); ADD water to dissolve and dilute to 100 mL.

3.2.2 20% potassium hydroxide solution. WEIGH 20 g of potassium hydroxide

(3.1.7); ADD water to dissolve and dilute to 100 mL.

3.2.3 Extraction solvent. WEIGH 1 g of BHT (3.1.6); USE 200 mL of

cyclohexane (3.1.1) to dissolve; ADD 400 mL of diethyl ether (3.1.2) and 400

mL of n-hexane (3.1.3), and MIX well.

3.3 Standard

Lutein (CAS number. 127-40-2), with a purity of not less than 98.0%.

3.4 Preparation of standard solutions

3.4.1 Standard stock solution (50 µg/mL). Accurately WEIGH 5 mg (accurate to

0.01 mg) of lutein (3.1.3); USE 0.1% BHT ethanol solution (3.2.4) to dissolve

and dilute to 100 mL. This standard stock solution can be stored for six months

by filling nitrogen and avoiding light in a refrigerator of -20 °C or below.

3.4.2 Standard working solutions. accurately PIPETTE 0.050 mL, 0.100 mL,

0.200 mL, 0.400 mL, 1.00 mL of standard stock solution of lutein (3.4.1) into 5

25 mL brown volumetric flasks; USE 0.1% BHT ethanol solution (3.2.4) to dilute

to volume; and OBTAIN a series of standard working solutions having

concentrations of 0.100 µg/mL, 0.200 µg/mL, 0.400 µg/mL, 0.800 µg/mL, and

2.00 µg/mL.

4 Instruments and equipment

4.1 Liquid chromatograph, with diode array detector or UV-detector.

4.2 UV-visible spectrophotometer.

4.3 Analytical balance. The sensitivity is 0.01 mg and 0.01 g.

4.7 Decompression concentrator.

4.8 Solid phase extraction plant.

4.9 Centrifuge. The speed is not less than 4500 r/min.

5 Analytical procedures

Note. Because lutein is sensitive to light, unless otherwise stated, all test operations shall

be performed in a yellow or red light source environment with no UV light below 500

nm.

5.1 Sample preparation

A certain number of samples are pulverized, homogenized, and divided as

required, and stored in a sample bottle. The prepared sample shall be filled with

nitrogen and sealed; and stored in a refrigerator at -20 °C or below.

5.2 Extraction

5.2.1 Foods with high fat content (such as infant formula, milk powder, ice

cream, bakery nuts, etc.)

5.3 Instrument reference conditions

5.3.1 Chromatographic column. C30 column, 5 µm, 250 mm×4.6 mm (inner

diameter) or equivalent;

5.3.2 Column temperature. 30 °C;
5.3.3 Mobile phase. methanol/water (88+12, volume ratio, containing 0.1%

BHT)-methyl tert-butyl ether (containing 0.1% BHT), gradient elution. 0 min~18

min, methanol/water is changed from 100% to 10%; 18.1 min, methanol/water

is changed from 10% to 100%, retained for 10 min;

5.4 Making of standard curve

The series of standard working solutions are separately injected into the liquid

chromatograph, to determine the corresponding peak area. USE the

concentration of standard working solution as the abscissa. USE the peak area

as the ordinate. The standard curve is drawn.

5.5 Determination of sample solution

The response value of lutein in the sample solution to be determined shall be

within the linear response range of the instrument, otherwise it shall be diluted

or concentrated appropriately.

6 Analysis results expression

The content of lutein in the sample shall be calculated according to formula (1).

7 Precision

The absolute difference between the two independent determination results,

obtained under repeated conditions, shall not exceed 15% of the arithmetic

mean.

8 Other

The detection limit of this method. For infant formula, milk powder, ice cream,

bakery nuts, and other foods, when the sampling amount is 2 g and the constant

volume is 5 mL, the detection limit is 3 µg/100 g. For liquid milk, etc., when the

sampling amount is 10 g and the constant volume is 25 mL, the detection limit

is 3 µg/100 g. For rice and flour products, jams, and other foods, when the

sampling amount is 5 g and the constant volume is 10 mL, the detection limit is

3 µg/100 g.

Appendix A

Method for correction of standard solution concentration

The lutein standard solution, after preparation, needs to be calibrated. TAKE 1

mL of standard stock solution; USE ethanol to dilute to 25 mL. PIPETTE this

solution into a 1 cm quartz cuvette. USE ethanol as a blank; USE a

spectrophotometer, under a wavelength of 445 nm, to determine the

absorbance A. According to formula (A.1), calculate the standard solution

concentration.

Appendix B

Liquid chromatogram of standard solution

B.1 Liquid chromatogram of lutein (trans) standard solution

The liquid chromatogram of lutein (trans) standard solution is shown in Figure

B.1.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download GB 5009.248-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 5009.248-2016