GB 5009.182-2017National food safety standard - Determination of aluminum in foods (English PDF)
食品安全国家标准 食品中铝的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB 5009.182-2017 in 30 minutes.
Issued by
National Health and Family Planning Commission of the PRC
Level / Type
National · Mandatory
Issue date
April 6, 2017
Implementation date
October 6, 2017
Scope
GB 5009.182-2017 is the English-translated version of 食品安全国家标准 食品中铝的测定.
GB 5009.182-2017 — This standard specifies some methods for determination of aluminum content in foods, such as spectrophotometry, inductively coupled plasma mass spectrometry, inductively coupled plasma emission spectrometry and graphite furnace atomic absorption spectrometry.
Method I in this standard applies to the detection of aluminum in foods containing aluminum-based food additives. Method II, method III and method IV are applicable to the detection of aluminum in foods. Method I. Spectrophotometry
Found what you need?
Document preview — GB 5009.182-2017
National Standard of the People's Republic of China
Issued by: National Health and Family Planning Commission of the PRC
Contents
- Foreword...3
- 1 Scope...4
- 2 Principles...4
- 3 Reagents and materials...4
- 4 Instrument and equipment...6
- 5 Analytical procedures...7
- 6 Analysis results expression...8
- 7 Precision...8
- 8 Others...8
- 9 Principles...9
- 10 Reagents and materials...9
- 11 Instrument and equipment...10
- 12 Analytical procedures...10
- 13 Analysis results expression...13
- 14 Precision...13
- 15 Others...13
- Appendix A Microwave digestion temperature-rise program...14
- Appendix B Pressure-tank digestion reference heating conditions...15
Foreword
For the determination method of aluminum, this standard replaces GB/T
5009.182-2003 "Determination of aluminum in flour products", GB/T 23374-
2009 "Determination of aluminium in foods - Inductively coupled plasma mass
spectrometry", GB/T 18932.11-2002 "Method for the determination of
potassium, phosphorus, iron, calcium, zinc, aluminium, sodium, magnesium,
boron, manganese, copper, barium, titanium, vanadium, nickel, cobalt,
chromium contents in honey. Inductively coupled plasma atomic emission
spectrometric method (ICP-AES)", SN/T 2208-2008 "Determination of sodium,
magnesium, aluminium, calcium, chromium, iron, nickel, copper, zinc, arsenic,
strontium, molybdenum, cadmium, lead, mercury, selenium, in aquatic products
- Microwave digestion - ICP/MS method ".
As compared with GB/T 5009.182-2003, the main changes of this standard are
as follows.
---The standard name is changed to "National food safety standard -
Determination of aluminium in foods";
---Improve method I spectrophotometry;
---Add inductively coupled plasma mass spectrometry as method II;
---Add inductively coupled plasma emission spectrometry as method III;
---Add graphite furnace atomic absorption spectrometry as method IV.
National food safety standard -
Determination of aluminum in foods
1 Scope
This standard specifies some methods for determination of aluminum content
in foods, such as spectrophotometry, inductively coupled plasma mass
spectrometry, inductively coupled plasma emission spectrometry and graphite
furnace atomic absorption spectrometry.
Method I in this standard applies to the detection of aluminum in foods
containing aluminum-based food additives. Method II, method III and method
IV are applicable to the detection of aluminum in foods.
Method I. Spectrophotometry
2 Principles
After the sample is treated, it is in ethylenediamine-HCl buffer solution (pH 6.7-
7.0), with the existence of Triton X-100 and cetylpyridinium bromide (CPB),
trivalence aluminum ion reacts with chrome azurol S to generate blue-green
quaternary micelle.
3 Reagents and materials
Unless otherwise indicated, the reagents used in this method are analytical
pure, the experimental water is the grade-3 water specified in GB/T 6682.
3.1 Reagents
3.1.1 Nitric acid (HNO3). guaranteed reagent.
3.1.2 Sulfuric acid (H2SO4). guaranteed reagent.
3.1.3 Hydrochloric acid (HCl). guaranteed reagent.
3.1.11 Ascorbic acid (C6H8O6).
3.2 Reagent preparation
3.2.1 Hydrochloric acid solution (1+1). MEASURE 50 mL of hydrochloric acid;
MIX it uniformly with 50 mL of water.
3.2.2 Sulfuric acid solution (1%). PIPETTE 1 mL of sulfuric acid; POUR slowly
into 80 mL of water; USE water to dilute it to 100 ml after cooling; MIX it
uniformly.
3.2.12 Ethylenediamine solution (1+2). MEASURE 10 mL of ethylenediamine;
slowly POUR into 20 mL of water; MIX it uniformly.
3.2.13 Ethylenediamine-hydrochloric acid buffer solution (pH6.7~7.0).
MEASURE 100 mL of ethylenediamine; slowly POUR into 200 mL of water
along glass rod; after cooling, ADD slowly 190 mL of hydrochloric acid along
glass rod; MIX it uniformly; if pH > 7.0 or pH < 6.7, USE hydrochloric acid
solution (1+1) or ethylenediamine solution (1+ 2) to adjust pH respectively.
3.2.14 Ascorbic acid solution (10 g/L). WEIGH 1 g of ascorbic acid; USE water
to dilute it to 100 mL; MIX uniformly. Prepare it before use.
3.3 Standards
Aluminum standard solution. 1000 mg/L. Or aluminum standard solution with a
certain concentration which is identified by national authentication and awarded
a reference material certificate.
3.4 Standard solution preparation
3.4.1 Aluminum standard intermediate solution (100 mg/L). Accurately
PIPETTE 1.00 mL of aluminum standard solution (1000 mg/L) into 10 mL
volumetric flask; ADD nitric acid solution (5%) to dilute it to the mark; MIX it
uniformly.
4 Instrument and equipment
Note. All glassware must be soaked in nitric acid solution (1+5) for more than 24h, washed
repeatedly with tap water, finally rinsed with water. Dry it by airing before use.
4.1 Spectrophotometer.
4.2 Balance. sensitivity is 1 mg.
4.5 Constant-temperature oven.
5 Analytical procedures
5.1 Sample Preparation
In the process of sampling and sample preparation, pay attention not to
contaminate the sample; avoid using aluminum-containing appliances.
5.2 Sample digestion
WEIGH 0.2 g ~ 3 g of sample (accurate to 0.001g) or accurately MOVE 0.500
mL ~ 5.00 mL of liquid sample into hard glass digestion tube or conical flask;
ADD 10 mL of nitric acid and 0.5 mL of sulfuric acid; HEAT it on adjustable
temperature-control electric furnace or hot plate, reference conditions.
5.3 Color reaction and colorimetric determination
Respectively PIPETTE 1.00 mL (V2) of sample digestive juice and blank
solution; PLACE them into 25 mL plugged colorimetric tube; ADD water to 10
mL. In addition, TAKE seven 25 mL plugged colorimetric tubes; ADD
respectively aluminum standard working solution 0 mL, 0.500 mL, 1.00 mL,
2.00 mL, 3.00 mL, 4.00 mL and 5.00 mL (in the series standard solution, the
mass of aluminum is 0 µg, 0.500 µg, 1.00 µg, 2.00 µg, 3.00 µg, 4.00 µg, 5.00
µg respectively); ADD 1 mL of sulfuric acid solution (1%) in each tube
successively; ADD water to 10 mL.
6 Analysis results expression
The aluminum content in the sample is calculated according to equation (1).
7 Precision
The absolute difference between two independent determinations obtained
under repeatability conditions shall not exceed 10% of the arithmetic mean.
8 Others
When the sampling weight is 1 g(or 1 mL) and constant volume is 50 mL, the
method detection limit is 8 mg/kg (or 8 mg/L) and the quantitative limit is 25
mg/kg (or 25 mg/L).
9 Principles
After sample digestion, it is atomized through graphite furnace to measure
absorbance value at 257.4 nm.
10 Reagents and materials
Unless otherwise indicated, the reagents used in this method are guaranteed
reagent, the experimental water is the grade-2 water specified in GB/T 6682.
10.1 Reagents
mL of water; MIX it uniformly.
10.2.2 Nitric acid solution (5+95). MEASURE 5 mL of nitric acid; POUR into 95
mL of water; MIX it uniformly.
10.3 Standards
Aluminum standard solution. 1000 mg/L. Or aluminum standard solution with a
certain concentration which is identified by national authentication and awarded
a reference material certificate.
10.4 Standard solution preparation
10.4.1 Aluminum standard intermediate solution (100 mg/L). Accurately
PIPETTE 1.00 mL of aluminum standard solution (1000 mg/L) into 10 mL
volumetric flask; ADD nitric acid solution (5+95) to dilute it to the mark; MIX it
uniformly.
11 Instrument and equipment
Note. All glassware and digestion pots must be soaked in nitric acid solution
(1+5) for more than 24h, washed repeatedly with tap water, finally rinsed with
water. Dry it by airing before use.
11.1 Graphite Furnace Atomic Absorption Spectrometer. Attached aluminum
11.4 Adjustable hot plate.
11.5 Microwave digestion instrument. equipped with Teflon digestion inner-tank.
11.6 Pressure digestion pot. equipped with Teflon digestion inner-tank.
11.7 Constant-temperature oven
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download GB 5009.182-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 5009.1-2025 — National food safety standard - Physical and chemical testing - General principles
GB 5009.11-2024 — National food safety standard - Determination of total arsenic and inorganic arsenic in food
GB 5009.111-2016 — National food safety standard - Determination of deoxynivalenol and its acetylated derivatives in food
Secure payment via Stripe
Payments accepted
GB 5009.182-2017