GB 5009.123-2023National food safety standard - Determination of chromium in foods (English PDF)

Also coversGB5009.123-2023

Open the GB 5009.123-2023 preview as PDF

Preview — first pages of GB 5009.123-2023

This is a limited preview

Buy now to download the full PDF

Issued by

NHC; SAMR

Level / Type

National · Mandatory

Issue date

September 6, 2023

Implementation date

September 6, 2024

Scope

GB 5009.123-2023 (National food safety standard - Determination of chromium in foods) is available as an English-translated PDF.

GB 5009.123-2023 — This Standard specifies the method for the determination of chromium in foods by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry. This Standard is applicable to the determination of chromium in foods. Method I - Graphite Furnace Atomic Absorption Spectrometry

Document preview — GB 5009.123-2023

National Standard of the People's Republic of China

Issued by: NHC; SAMR

Contents

  • Foreword...3
  • 1 Scope...4
  • Method I - Graphite Furnace Atomic Absorption Spectrometry...4
  • 2 Principle...4
  • 3 Reagents and Materials...4
  • 4 Instruments and Equipment...5
  • 5 Analytical Procedures...6
  • 6 Expression of Analysis Results...8
  • 7 Precision...9
  • 8 Others...9
  • Method II - Inductively Coupled Plasma Mass Spectrometry...9

Foreword

This Standard serves as a replacement of GB 5009.123-2014 National Food Safety Standard -

Determination of Chromium in Foods.

In comparison with GB 5009.123-2014, the main changes are as follows.

---The second method "inductively coupled plasma mass spectrometry" is added;

---Specimen preparation is modified;

---The wet digestion method, pressure tank digestion method, microwave digestion

method and dry digestion method are modified.

National Food Safety Standard - Determination of

Chromium in Foods

1 Scope

This Standard specifies the method for the determination of chromium in foods by graphite

furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry.

This Standard is applicable to the determination of chromium in foods.

Method I - Graphite Furnace Atomic Absorption

Spectrometry

2 Principle

After the specimen is digested, atomize it in a graphite furnace, at 357.9 nm, determine the

absorbance. Within a certain concentration range, the absorbance value of chromium is

proportional to the chromium content. Conduct quantitative comparison with standard series

solutions.

3 Reagents and Materials

Unless it is otherwise specified, the reagents used in this Method are all excellent-grade pure,

and the water is Grade-2 water specified in GB/T 6682.

3.1 Reagents

3.1.1 Nitric acid (HNO3).
3.1.2 Perchloric acid (HClO4).
3.1.3 Ammonium dihydrogen phosphate (NH4H2PO4).

3.2 Preparation of Reagents

3.3 Reference Material

Potassium dichromate (K2Cr2O7, CAS No.. 7778-50-9). purity > 99.99%, or a standard

substance certified by the state and awarded a reference material certificate.

3.4 Preparation of Standard Solutions

3.4.1 Chromium standard stock solution (1,000 mg/L). accurately weigh-take 0.2829 g of

potassium dichromate (110 C, bake for 2 h), dissolve it in water, then, transfer into a 100 mL

volumetric flask. Use nitric acid solution (5 + 95) to dilute it to the scale and evenly mix it. The

mass concentration of chromium in this solution is 1,000 mg/L.

4 Instruments and Equipment

NOTE. all glassware and polytetrafluoroethylene digestion inner tanks need to be soaked in nitric

acid solution (1 + 5) overnight, repeatedly rinsed with tap water, and finally, thoroughly

rinsed with water.

4.1 Atomic absorption spectrometer. equipped with graphite furnace atomizer and chromium

hollow cathode lamp.

4.2 Electronic balance. with a division value of 0.1 mg and 1 mg.

4.3 Adjustable electric heating plate or adjustable electric stove.

4.6 Constant-temperature drying oven.

4.7 Muffle furnace.

5 Analytical Procedures

5.1 Specimen Preparation

5.1.1 Solid-state samples
5.1.1.1 Dry samples

For samples with low-water content, such as. beans, grains, fungi, tea, dried fruits and baked

goods, etc., take the edible part, when necessary, use a high-speed pulverizer to evenly crush it.

For powdery samples that are uniform in shape, such as. solid dairy products, protein powder

and flour, etc., evenly shake them.

5.1.2 Liquid samples

For samples, such as. soft drinks and condiments, etc., evenly shake them.

5.1.3 Semi-solid samples

Evenly mix them.

5.2 Test Conditions of the Method

5.2.1 Specimen pre-treatment
5.2.1.1 Wet digestion method

For solid specimens, weigh-take 0.2 g ~ 3 g (accurate to 0.001 g). For liquid specimens,

accurately transfer-take or weigh-take 0.500 mL (g) ~ 5.00 mL (g) (accurate to 0.001 g) into a

digestion tube with scale.

5.2.1.2 Microwave digestion method

For solid specimens, weigh-take 0.2 g ~ 0.5 g (accurate to 0.001 g; for samples containing

relatively high-water content, the sampling size can be appropriately increased to 1 g). For

liquid specimens, accurately transfer-take or weigh-take 0.500 mL (g) ~ 3.00 mL (g) (accurate

to 0.001 g) into a microwave digestion tank. For samples containing ethanol or carbon dioxide,

firstly heat them at a low temperature to remove ethanol or carbon dioxide, add 5 mL ~ 10 mL

of nitric acid, in accordance with the operation procedures of microwave digestion, digest the

specimen.

5.2.1.4 Dry digestion method

For solid specimens, weigh-take 0.5 g ~ 5 g (accurate to 0.001 g); for liquid specimens,

accurately transfer-take or weigh-take 2.00 mL (g) ~ 10.0 mL (g) (accurate to 0.001 g) into a

crucible, and heat it over low heat; carbonize it, until it becomes smokeless. Then, transfer it

into a muffle furnace, at 550 C, ash it for 3 h ~ 4 h.

5.3 Reference Conditions of Instruments

See Table A.2 for instrument operating conditions.

5.4 Drawing of Standard Curve

In accordance with the mass concentration from low to high, respectively take 10 L of the

standard series of solutions and 5 L of the ammonium dihydrogen phosphate solution (select

the optimal sample injection volume in accordance with the instrument used), meanwhile, inject

it into the graphite tube. After atomization, determine the absorbance value, and by taking the

mass concentration as the x-coordinate and the absorbance value as the y-coordinate, draw a

standard curve.

6 Expression of Analysis Results

The content of chromium in the specimen is calculated in accordance with Formula (1).

7 Precision

When the chromium content in the specimen is > 1 mg/kg (mg/L), the absolute difference

between the results of two independent determinations obtained under repeatability conditions

shall not exceed 10% of the arithmetic mean.

8 Others

When the sampling size is 0.5 g or 2 mL and the constant volume is 10 mL, the detection limit

of this Method is 0.01 mg/kg or 0.003 mg/L, and the quantitation limit is 0.03 mg/kg or 0.008

mg/L.

Appendix A

Microwave Digestion Temperature Rise Program and Instrument

Reference Conditions of Graphite Furnace Atomic Absorption

Spectrometry

A.1 The microwave digestion temperature rise program is shown in Table A.1.

Table A.1 -- Microwave Digestion Temperature Rise Program

A.2 The instrument reference conditions of graphite furnace atomic absorption spectrometry

are shown in Table A.2.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

How to Buy GB 5009.123-2023

  1. 1Add to cart. Click the "Buy GB 5009.123-2023" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 5009.123-2023

$125.00

$105.00for partners