Scope
GB 47370-2026 is the English-translated version of 热气溶胶灭火装置.
GB 47370-2026 is the mandatory Chinese national standard for condensed aerosol fire extinguishing equipment — the pipeless units, floor-standing or suspended, in which a solid compound burns to generate the extinguishing aerosol. It applies where the mass of the aerosol forming compound is not greater than 3 kg, and excludes hand-held units and units for locations with an explosion hazard. It sets the requirements, the inspection rules, the content of the instruction manual and the marking, packaging and storage, gives the classification and the model designation system — QRR followed by the charge mass, the fire categories AM, B and AJ, the mounting letter L or G and the letter W for the temperature-restricted type — and describes thirty-two test methods, from discharge performance, temperature cycling, damp heat, vibration, shock and drop through the fire and concentration-distribution tests to the impact, electrostatic and friction sensitivity of the aerosol forming compound. Equipment shall work from −20 °C to +55 °C at a relative humidity of not more than 95 %; the declared discharge time shall be not more than 90 s above 1 kg of compound and not more than 40 s at 1 kg and below, within ±10 % of the declared value. Six normative annexes fix the assay of potassium and strontium nitrate and the test programmes and sample counts. In force from 1 April 2027.
Document preview — GB 47370-2026
National Standard of the People's Republic of China
- ICS
- 13.220.10
- Classification
- C 83
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and definitions1
- 4 Classification2
- 5 Model designation3
- 6 Requirements3
- 6.1 Extinguishing equipment3
- 6.2 Actuating device6
- 6.3 Feedback element7
- 6.4 Control device7
- 6.5 Suspension bracket (base)7
- 6.6 Coolant (cooling equipment)7
- 6.7 Compound forming the aerosol fire extinguishing agent7
- 6.8 Condensed aerosol fire extinguishing agent8
- 7 Test methods9
- 8 Inspection rules32
- 8.1 Inspection classification, inspection items and test procedure32
- 8.2 Sampling method and number of samples34
- 8.3 Judgement of the inspection result34
- 9 Requirements for drafting the instruction manual34
- 10 Marking, packaging and storage35
- 10.1 Marking35
- 10.2 Packaging35
- 10.3 Storage35
- Annex A (normative) Determination of the potassium nitrate content36
- Annex B (normative) Determination of the strontium nitrate content38
- Annex C (normative) Test procedure and number of samples for the extinguishing equipment40
- Annex D (normative) Test procedure and number of samples for the electrical actuating device42
- Annex E (normative) Test procedure and number of samples for the thermal actuating device43
- Annex F (normative) Test procedure and number of samples for the control device44
- Annex G (informative) Test method for the corrosivity of the solid deposit of the condensed aerosol fire extinguishing agent45
Foreword
This document was drafted in accordance with the rules given in GB/T 1.1-2020 “Directives for standardization — Part 1: Rules for the structure and drafting of standardizing documents”.
Attention is drawn to the possibility that some of the content of this document may be the subject of patent rights. The issuing body of this document bears no responsibility for identifying such patent rights.
This document was proposed by, and is under the jurisdiction of, the National Fire and Rescue Administration.
Introduction
Where the raw materials and the components used in the condensed aerosol fire extinguishing equipment described in this document are civil explosive articles or hazardous chemicals, the corresponding safety management requirements are laid down in the Regulations on the Safety Management of Civil Explosive Articles, the Regulations on the Safety Management of Hazardous Chemicals, the Measures for the Public Security Administration of Hazardous Chemicals Readily Convertible to Explosives and other such documents. This document is used together with those documents.
Warning
The test procedures covered by this document may involve a risk of explosion, electric shock and asphyxiation; test personnel shall take appropriate safety measures.
1 Scope
This document specifies the requirements, the inspection rules, the requirements for drafting the instruction manual and the marking, packaging and storage of condensed aerosol fire extinguishing equipment; it gives the classification and the method of composing the model designation, and describes the corresponding test methods.
This document applies to pipeless condensed aerosol fire extinguishing equipment in which the mass of the compound forming the aerosol fire extinguishing agent is not greater than 3 kg.
This document does not apply to hand-held condensed aerosol fire extinguishing equipment or to condensed aerosol fire extinguishing equipment used in locations with an explosion hazard.
2 Normative references
The contents of the following documents constitute indispensable provisions of this document through normative reference in the text. For dated references, only the edition corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB 190 Packing symbol of dangerous goods · GB/T 191 Packaging — Pictorial marking for handling of goods · GB 4066-2017 Dry powder fire extinguishing agent · GB/T 9174 General rules for packaging of goods in transportation · GB/T 9969 General principles for preparation of instructions for use of industrial products · GB 12463 General technical requirements for packaging of dangerous goods for transport · GB/T 25208-2010 Environmental test methods for fixed fire extinguishing system products · XF 61-2010 General technical requirements for driving and control devices of fixed fire extinguishing systems
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 Condensed aerosol fire extinguishing agent
The fire extinguishing substance produced by the aerosol fire extinguishing agent forming compound through a combustion reaction.
3.2 Compound forming aerosol fire extinguishing agent
The solid chemical mixture that produces the condensed aerosol fire extinguishing agent (3.1) through a combustion reaction.
Note: it generally consists of an oxidizer, a reducer and additives.
3.3 Condensed aerosol fire extinguishing agent generator
The assembly in which the compound forming the aerosol fire extinguishing agent (3.2) is formed to the design requirements and fitted with the initiating charge.
3.4 Condensed aerosol fire extinguishing equipment
Equipment that makes the compound forming the aerosol fire extinguishing agent (3.2) produce the condensed aerosol fire extinguishing agent (3.1) through a combustion reaction.
Note 1: it usually consists of an actuating device, a condensed aerosol fire extinguishing agent generator (3.3), a coolant (cooling equipment), a feedback element (where applicable) and an enclosure.
Note 2: condensed aerosol fire extinguishing equipment is referred to below as “the extinguishing equipment”.
3.5 Actuating device
The component able to supply, by electrical, thermal, chemical, mechanical or other means, the initial energy necessary for the combustion reaction of the compound forming the aerosol fire extinguishing agent (3.2).
3.6 Extinguishing application density
The mass of the compound forming the aerosol fire extinguishing agent (3.2) needed to extinguish a fire of a given combustible in a unit volume of space.
Note: the unit of extinguishing application density is grams per cubic metre (g/m³).
3.7 Discharge lagging time
The time from the reception of the actuating signal by the extinguishing equipment to the beginning of the discharge of the condensed aerosol fire extinguishing agent (3.1) from the discharge port.
3.8 Discharge time
The time from the beginning to the end of the discharge of the condensed aerosol fire extinguishing agent (3.1) from the discharge port.
3.9 Extinguishing time
The time from the beginning of the discharge of the condensed aerosol fire extinguishing agent (3.1) from the discharge port to the extinction of the open flame.
3.10 Coolant (cooling equipment)
The medium or the device installed inside the extinguishing equipment that effectively lowers the temperature of the condensed aerosol fire extinguishing agent (3.1) before it passes through the discharge port.
3.11 Thermal clearance
The distance between the discharge port and the point at which the condensed aerosol fire extinguishing agent (3.1) discharged by the extinguishing equipment reaches a specified temperature, during the discharge.
3.12 Discharge port temperature
The maximum temperature at 5 mm from the outer edge of the discharge port during the discharge of the condensed aerosol fire extinguishing agent (3.1) by the extinguishing equipment.
3.13 Temperature-restricted extinguishing equipment
Extinguishing equipment for which there is a limiting requirement on the discharge port temperature.
3.14 Thermal stability
The property by which the compound forming the aerosol fire extinguishing agent (3.2) does not decompose under the action of heat.
4 Classification
4.1 According to the way the extinguishing equipment is installed it is divided into: a) floor-standing extinguishing equipment; b) suspended extinguishing equipment.
4.2 According to the type of limit on the discharge port temperature it is divided into: a) temperature-restricted extinguishing equipment; b) non-temperature-restricted extinguishing equipment.
5 Model designation
The model designation is composed as follows: QRR for condensed aerosol fire extinguishing equipment; then the nominal mass of the compound forming the aerosol fire extinguishing agent, in kilograms (kg); then the extinguishing category, AM for the surface fire of a wood crib, B for a class B fire and AJ for a polymer fire; then the way the extinguishing equipment is installed, L for floor-standing and G for suspended; then the type of limit on the discharge port temperature, not marked for the non-temperature-restricted type and W for the temperature-restricted type; and finally the manufacturer’s own designation.
Example 1: QRR3AMBL denotes non-temperature-restricted, floor-standing condensed aerosol fire extinguishing equipment able to extinguish the surface fire of an AM wood crib and a class B fire, with a nominal mass of the aerosol forming compound of 3 kg.
Example 2: QRR1AMGW denotes temperature-restricted, suspended condensed aerosol fire extinguishing equipment able to extinguish the surface fire of an AM wood crib, with a nominal mass of the aerosol forming compound of 1 kg.
Remaining clauses in the full document
- 6 Requirements
- 7 Test methods
- 8 Inspection rules
- 9 Requirements for drafting the instruction manual
- 10 Marking, packaging and storage
- Annex A (normative) Determination of the potassium nitrate content
- Annex B (normative) Determination of the strontium nitrate content
- Annex C (normative) Test procedure and number of samples for the extinguishing equipment
- Annex D (normative) Test procedure and number of samples for the electrical actuating device
- Annex E (normative) Test procedure and number of samples for the thermal actuating device
- Annex F (normative) Test procedure and number of samples for the control device
- Annex G (informative) Test method for the corrosivity of the solid deposit of the condensed aerosol fire extinguishing agent
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 52 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB 4066-2017Powder extinguishing agent
- GB/T 9174General specification for transport packages of general cargo
- GB/T 9969General principles for preparation of instructions for use of industrial products
- GB 12463General specifications for transport packages of dangerous goods
- GB/T 25208-2010Environmental test methods for fixed extinguishing systems
GB 190 · XF 61-2010
Similar standards
GB 4066|GB/T 25208|XF 61
How to Buy GB 47370-2026
- 1Add to cart. Click the "Buy GB 47370-2026" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 12463-2009 — General specifications for transport packages of dangerous goods
GB 1903.72-2025 — National food safety standard - Food nutritional fortifier - Sodium iron ethylenediaminetetraacetate
GB 1903.73-2025 — National food safety standard - Food nutrition fortifier - Sodium chloride
Secure payment via Stripe
Payments accepted
GB 47370-2026
$1,070.00