GB 4103.10-1983Methods for chemical analysis of lead and lead alloys -- Part 10: Determination of silver content (English PDF)
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for GB 4103.10-1983 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
GB 4103.10-1983 (Methods for chemical analysis of lead and lead alloys -- Part 10: Determination of silver content) is available as an English-translated PDF.
GB 4103.10-1983 — This section GB/T 4103 provisions of the determination of lead and lead alloys in silver content. This section applies to the determination of lead and lead alloys in silver content.
Found what you need?
Document preview — GB 4103.10-1983
National Standard of the People's Republic of China
- ICS
- 77.120.60
- Classification
- H 13
- Replacing
- GB/T 4103.10-2000
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 General
- 4.1 Determination of Range
- 4.2 Principle
- 4.3 Reagents
Foreword
GB/T 4103 "Methods for chemical analysis of lead and lead alloys" is divided into 16 parts.
--- Part 1. Determination of tin content;
--- Part 2. Determination of antimony content;
--- Part 3. Determination of copper content;
--- Part 4. Determination of iron content;
--- Part 5. Determination of bismuth content;
--- Part 6. Determination of arsenic content;
--- Part 7. Determination of the amount of selenium;
--- Part 8. Determination of tellurium content;
--- Part 9. Determination of calcium;
--- Part 10. Determination of the amount of silver;
--- Part 11. Determination of zinc content;
--- Part 12. Determination of thallium content;
--- Part 13. Determination of aluminum content;
--- Part 14. Determination of cadmium content by flame atomic absorption spectrometry;
--- Part 15. Determination of nickel content by flame atomic absorption spectrometry;
--- Part 16. copper, silver, bismuth, arsenic, antimony, tin, zinc contents Optical emission spectroscopy.
This is Part 10 GB/T 4103's.
This Part replaces GB/T 4103.10-2000 "of lead and lead alloys - Determination of silver content", and GB/T 4103.10-Compared to 2000, the main changes are as follows.
--- Additional fire assay Determination of silver content;
--- Measuring range extended from 0.0003% to ~ 1.5 to 0.0003% to 2.0%, by flame atomic absorption spectrometry - 0.0003% Adjusted 1.5% to 0.0003% to 0.50%, measured fire assay ranges from > 0.50% to 2.00%;
--- Supplementary terms of precision.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd., Beijing Mining Research Institute, Shaanxi Dongling Smelting Co., Ltd., White Silver colored copper Northwest Limited.
A method of drafting this section. Henan Yuguang Gold & Lead Co., Lingnan Shaoguan smelter, Beijing Mining Research Institute, Zhu Zhou Smelter Group Co., Ltd., Hunan Nonferrous Metals Group Co., Ltd. Shuikoushan.
This section Method two drafting units. Lingnan Shaoguan smelter, Beijing Mining Research Institute, Zhuzhou Smelter Group Co., Ltd.
1 Scope
This section GB/T 4103 provisions of the determination of lead and lead alloys in silver content.
This section applies to the determination of lead and lead alloys in silver content.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6682 analytical laboratory use specifications and test methods (ISO 3696) GB/T 12806 laboratory glassware single marking flask (ISO 1042) GB/T 12808 laboratory glassware single marking pipette (ISO 648) GB/T 12809 Laboratory glassware Glass Container design and construction principles (ISO 384) GB/T 12810 laboratory glassware gauge capacity calibration and use (ISO 4787)
3 General
3.1 Unless otherwise stated, the use of analytical reagent only recognized in the analysis; the water is distilled or deionized water or equivalent purity, shall comply with the provisions of GB/T 6682's.
3.2 instruments shall be within the test cycle, the performance indicators should meet the technical parameters required for verification; glass containers GB/T 12808, GB/T 12809, GB/T 12806 specified in Class A, with reference to the specific use requirements GB/T 12810 in.
4 a method of flame atomic absorption spectrometry
4.1 Determination of Range
This method is applicable to the determination of lead and lead alloys in silver content. Determination of silver range 0.0003 to 0.50% (mass fraction).
4.2 Principle
The sample is dissolved in nitric acid, tartaric acid in dilute nitric acid medium, using air - acetylene flame atomic absorption spectrometer wavelength 328.1nm Absorbance was measured at silver.
4.3 Reagents
4.3.1 nitrate (rho1.42g/mL), pure class distinctions.
4.3.2 nitric acid (11).
4.3.3 nitric acid (13).
4.3.4 mixed acid. Weigh 30g tartaric acid dissolved in 200mL of water, 100mL added nitric acid (4.3.1).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 12808Laboratory glassware - One mark pipettes
- GB/T 12810Laboratory glassware - Capacity methods testing and use of volumetric instruments
ISO 3696 · GB/T 12806 · ISO 1042 · ISO 648 · GB/T 12809 · ISO 384 · ISO 4787
How to Download GB 4103.10-1983
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12808-2015 — Laboratory glassware - One mark pipettes
GB/T 12810-2021 — Laboratory glassware - Capacity methods testing and use of volumetric instruments
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
Secure payment via Stripe
Payments accepted
GB 4103.10-1983
$204.00