GB 37489.5-2019Hygienic design specification for public places - Part 5: Barber and beauty (English PDF)
公共场所设计卫生规范 第5部分:美容美发场所
Open the GB 37489.5-2019 preview as PDF
This is a limited preview
Buy now to download the full PDF (4 pages)
Issued by
SAMR; SAC
Level / Type
National · Mandatory
Issue date
April 4, 2019
Implementation date
November 1, 2019
Scope
GB 37489.5-2019 is the English-translated version of 公共场所设计卫生规范 第5部分:美容美发场所.
The hygiene rules that a Chinese barber shop or beauty salon has to be designed to before it is built, extended or rebuilt. A salon is a place where blades, towels, basins and cups pass from one customer to the next and where perming and dyeing chemicals are used in a small closed room, so most of what can go wrong there - skin and scalp infections, fungal disease, chemical fumes, electric shock in a wet area - is settled at the drawing-board rather than by cleaning afterwards. This part of GB 37489 fixes the basic requirements and the design hygiene requirements for the overall layout and functional zoning, for the individual rooms, for the heating, ventilation and air conditioning, for the drainage and for the electrical installations of such premises. It applies to beauty salons and to barber and hairdressing shops, and it does not apply to medical cosmetology establishments, which are governed elsewhere. It is Part 5 of a five-part standard that sits inside a wider family of public-place hygiene standards covering inspection methods, hygiene management, hygiene indicators and hygienic evaluation. It partly replaces the design requirements of the old GB 9666-1996 hygienic standard for barbershops and beauty shops, refining the rules on layout and on the beauty and hair areas, and adding new ones for the cleaning and disinfection room, the storage room, and the water supply, drainage and electrical design. Designers, builders, salon operators and the local health supervision offices are the ones who work from it; clause 5.1.2 is recommendatory and the rest of the part is mandatory.
Document preview — GB 37489.5-2019
National Standard of the People's Republic of China
- ICS
- 13.020
- Classification
- C 51
- Replacing
- GB 9666-1996 (in part)
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Basic requirements
- 4 Overall layout and functional zoning
- 5 Individual rooms
- 5.1 Beauty and hairdressing areas
- 5.2 Cleaning and disinfection room (area)
- 6 Heating, ventilation and air conditioning
- 7 Drainage
- 8 Electrical installations
Foreword
Clause 5.1.2 of this part is a recommendatory provision; the remainder are mandatory provisions.
The series of hygiene standards for public places is made up of five standards: GB/T 18204 Examination methods for public places, GB 37487 Hygiene management specification for public places, GB 37488 Hygiene indicators and limits requirements for public places, GB 37489 Hygienic design specification for public places, and GB/T 37678 Hygienic evaluation specification for public places.
GB 37489 Hygienic design specification for public places is divided into five parts: Part 1: General principles; Part 2: Accommodation places; Part 3: Artificial swimming places; Part 4: Bathing places; Part 5: Barber and beauty places. This part is Part 5 of GB 37489.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part partly replaces the content concerning design hygiene requirements in GB 9666-1996 Hygienic standard for barbershops and beauty shops. Compared with GB 9666-1996, the main technical changes are the following: the hygiene requirements for the overall layout and functional zoning design have been refined; the hygiene requirements for the design of the beauty and hairdressing areas have been refined; hygiene requirements for the design of the cleaning and disinfection room (area) and of the storage room (area) have been added; the hygiene requirements for the design of the heating, ventilation and air conditioning have been refined; and hygiene requirements for the design of the water supply and drainage and of the electrical installations have been added.
This part was proposed by and is under the jurisdiction of the National Health Commission of the People's Republic of China.
The previous editions of the standard replaced by this part were GB 9666-1988 and GB 9666-1996.
1 Scope
The hygiene rules that a Chinese barber shop or beauty salon has to be designed to before it is built, extended or rebuilt. A salon is a place where blades, towels, basins and cups pass from one customer to the next and where perming and dyeing chemicals are used in a small closed room, so most of what can go wrong there - skin and scalp infections, fungal disease, chemical fumes, electric shock in a wet area - is settled at the drawing-board rather than by cleaning afterwards. This part of GB 37489 fixes the basic requirements and the design hygiene requirements for the overall layout and functional zoning, for the individual rooms, for the heating, ventilation and air conditioning, for the drainage and for the electrical installations of such premises. It applies to beauty salons and to barber and hairdressing shops, and it does not apply to medical cosmetology establishments, which are governed elsewhere. It is Part 5 of a five-part standard that sits inside a wider family of public-place hygiene standards covering inspection methods, hygiene management, hygiene indicators and hygienic evaluation. It partly replaces the design requirements of the old GB 9666-1996 hygienic standard for barbershops and beauty shops, refining the rules on layout and on the beauty and hair areas, and adding new ones for the cleaning and disinfection room, the storage room, and the water supply, drainage and electrical design. Designers, builders, salon operators and the local health supervision offices are the ones who work from it; clause 5.1.2 is recommendatory and the rest of the part is mandatory.
This part of GB 37489 specifies the basic requirements for newly built, extended and rebuilt barber and beauty places, together with the design hygiene requirements for the overall layout and functional zoning, for the individual rooms, for the heating, ventilation and air conditioning, for the drainage and for the electrical installations.
This part applies to beauty salons and to barber (hairdressing) shops.
This part does not apply to medical cosmetology places.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB 37489.1 Hygienic design specification for public places - Part 1: General principles.
JGJ 16 Code for electrical design of civil buildings.
3 Basic requirements
The requirements of GB 37489.1 shall be met.
4 Overall layout and functional zoning
Functional areas shall be provided and laid out rationally: a beauty area, a hairdressing area, a cleaning and disinfection room (area), a storage room (area) and a changing room (locker).
In premises offering both beauty and hairdressing services, the beauty operating area and the hairdressing operating area shall be separated from one another.
Clauses 4.3 to 4.5 tie three further requirements to the business floor area of the premises: whether the perming and dyeing work has to be given a separate workroom or only a separate work area; whether the cleaning and disinfection of public articles and utensils has to be given a separate room or only an area; and whether the storage has to be a separate room or only an area. The floor area at which the requirement changes is in the standard.
5.1 Beauty and hairdressing areas
Clause 5.1.1 sets minimum business floor areas for beauty places and for hairdressing places, and the recommendatory clause 5.1.2 sets the service area for each beauty bed and each hairdressing seat together with the spacing between beds and between chairs; the figures are in the standard.
Hairdressing places shall be provided with running-water hair washing equipment, and the ratio of hair washing equipment to seats shall not be lower than the ratio given in the standard.
5.2 Cleaning and disinfection room (area)
A cleaning and disinfection room (area) for beauty and hairdressing tools shall be provided.
Where public articles and utensils such as towels, face towels, bed sheets, quilt covers, massage gowns and slippers are supplied and are cleaned and disinfected on the premises, a cleaning and disinfection room (area) shall be set up, and inside it there shall be dedicated cleaning and disinfection tanks for towels, face towels, bed sheets, quilt covers, massage gowns and slippers.
Where cups are supplied and are cleaned and disinfected on the premises, a dedicated cleaning and disinfection room shall be set up. Where physical disinfection is used, the room shall contain a washing sink and a disinfection cabinet. Where chemical disinfection is used, dedicated decontamination, disinfection and rinsing tanks for cups shall be provided in the room, and the capacity and depth of the disinfection tank shall be able to meet the needs of immersion disinfection.
6 Heating, ventilation and air conditioning
Mechanical ventilation facilities shall be provided in the perming and dyeing workroom (area).
Mechanical ventilation facilities shall be provided in damp areas such as the hair washing area.
In areas where coal-fired or gas-fired equipment is used, mechanical ventilation devices and devices for the monitoring of, and alarm for, toxic and harmful gases shall be provided.
Air ducts and their fittings shall be made of anti-corrosion materials or shall be given corresponding anti-corrosion treatment.
7 Drainage
A hair filtering device shall be provided.
8 Electrical installations
The requirements of JGJ 16 shall be met.
Sealed luminaires made of corrosion-resistant material, or open luminaires with waterproof lamp holders, shall be used, and every part shall be given anti-corrosion or waterproof treatment.
An earth leakage protection switch shall be provided.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
Referenced standards
Normative references
JGJ 16 Code for electrical design of civil buildings
How to Buy GB 37489.5-2019
- 1Add to cart. Click the "Buy GB 37489.5-2019" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 37489.1-2019 — Hygienic specification for the design of public place-Part 1: General rules
GB 37489.2-2019 — Hygienic design specification for public places-Part 2: Public accommodation
GB 37489.3-2019 — Hygienic design specification for public places - Part 3: Artificial swimming place
Secure payment via Stripe
Payments accepted
GB 37489.5-2019
$70.00