GB 30734-2014Luminaires for firefighters (English PDF)
消防员照明灯具
Open the GB 30734-2014 preview as PDF
This is a limited preview
Buy now to download the full PDF (20 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Mandatory
Issue date
March 27, 2014
Implementation date
April 1, 2015
Scope
GB 30734-2014 is the English-translated version of 消防员照明灯具.
GB 30734-2014 is the Chinese national standard on luminaires for firefighters, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 27 March 2014 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 April 2015. Classification: ICS 13.220.10, CCS C85. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB 30734-2014
National Standard of the People's Republic of China
- ICS
- 13.220.10
- Classification
- C85
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope
- 1.0 Portable II Type
- 1.5 Portable type I
- 2 Normative references
- 3 Terms and Definitions
- 4 Classification and models
- 5 Technical requirements
- 5.1 General Requirements
- 5.2 Functional requirements
- 5.3 Performance Requirements
- 5.3.1 Appearance and assembly
- 5.3.2 Quality sqrt sqrt sqrt 5
- 5.3.3 Illuminance sqrt sqrt sqrt 6
- 5.3.4 Continuous and stable operating hours Light sqrt Low Light sqrt 7
- 5.3.5 Low voltage Alarm time Light sqrt Low Light sqrt 8
- 5.3.6 Low voltage state Continuous working time Light sqrt Low Light sqrt 9
- 5.3.7 Insulation sqrt 10
- 5.3.8 Withstand voltage characteristic sqrt
- 5.3.11 Switch reliability sqrt 19
- 5.3.12 Enclosure class sqrt 20
- 6 Test methods
- 6.2 Function Test
- 7 Inspection rules
- 7.3 Type inspection
- 8.1.1 Lamps sign sqrt sqrt sqrt 21
- 8.1.2 Charger mark sqrt sqrt sqrt
- 10 Drop height Wearable
Foreword
The first chapter of this standard 8.1 5,7 mandatory, the rest are recommended. This standard is prepared in accordance with GB/T 1.1-2009 given rules. The standard proposed by the People's Republic of China Ministry of Public Security. This standard by the National Standardization Technical Committee firefighters Fire Protection Equipment Technical Committee (SAC/TC113/SC12) centralized. This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security. The main drafters of this standard. Ma Weiguang, Zhou Kai, Li Rui Kun, Yan Haibo, Wu Yun, Cao Yongqiang, Zhang Yan, Chang Song, Liu Yongmei, Liusu Yan, Xie Chunlong, Xu Jian, Li Miaohua. Firemen Lighting
1 Scope
GB 30734-2014 is the Chinese national standard on luminaires for firefighters, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 27 March 2014 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 April 2015. Classification: ICS 13.220.10, CCS C85. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This standard specifies the definition of firefighters lighting, classification and models, technical requirements, test methods, inspection rules, marking, packaging, transport Transport and storage. This standard applies when firefighters were fighting and rescue operations for single use lighting in a variety of low-light settings.
1.0 Portable II Type
0.5 Drop directions X, Y, Z Number of drops 1 per axis Nonoperating
5.3.11 Switch reliability Lamps after 50,000 switching reliability test should be kept intact, and the lamps shall be able to light up and to achieve strong, low-light switch.
5.3.12 enclosure class Luminaire enclosure rating requirements should be GB/T 4208-2008 the provisions of IP66/IP67 or IP66/IP68 of. When protection Class IP66/IP68, the manufacturer shall identify the diving depth and duration of the lamp.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191-2008 Packaging - Pictorial signs
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold
GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat
GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. Damp heat (12h 12h cycle)
GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
GB 3836.1-2010 explosive atmospheres - Part 1. General requirements for equipment
GB 4208-2008 shell protection (IP code)
GB 7000.1-2007 Luminaires - Part 1. General requirements and tests
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Firefighters lighting luminaireforfirefighter Lighting firefighters single use.
3.2 Wearable firefighters lighting wearableluminaireforfirefighter Fixed firefighters wear when used in a certain part of the body of firemen lighting.
3.3 Portable type I firefighters lighting typeIhandheldluminaireforfirefighter Mass of less than or equal to 1.5kg, when using hand-held or portable lighting light firefighters.
3.4 Portable II-based firefighters and lighting typeIIhandheldluminaireforfirefighter Mass greater than 1.5kg but less than or equal to 25kg, when using a portable or drag heavy firefighters lighting.
3.5 Lamp lightingassembly Lighting fixture part, by the light emitting devices, reflectors, consisting of transparent components.
4 Classification and models
4.1 Classification Fireman lighting (hereinafter referred to as lamp) in accordance with the use classification, category and code are shown in Table 1. Table
5.1 General Requirements
5.1.1 lighting power supply should be used rechargeable batteries, battery replaceable lamps should be equipped with an independent battery charging cradle.
5.1.2 Lamps charger plug should be used with AC-DC converter separate structure, fixture or charger should be set to charge and discharge protection circuit.
5.1.3 explosion-proof lamps shall comply with the requirements of GB 3836.1-2010.
5.1.4 wearable lamps should have a fire helmet match fixing fittings.
5.2 Functional requirements
5.2.1 The lamps should have a strong, low-light switching function.
5.2.2 The lamps should have flashes of low-voltage alarm function.
5.3.1 Appearance and assembly
5.3.1.1 Exterior lighting should be clean, smooth, clean, non-fouling, corrosion, scratches, burrs, cracks, deformation phenomena.
5.3.1.2 Each component mounting fixtures should be complete, accurate, reliable, no defects, dislocation, loosening, switching operation should be convenient, flexible and reliable.
5.3.2 Quality Quality lamps (including battery and accessories) shall comply with the provisions of Table 2. Table 2 units of kilograms Quality category Wearable <=
0.15 Portable I type <=1.5 II type >
5.3.3 Illumination When you press the test method specified in 6.5, lighting illuminance values under steady state should be in accordance with Table 3. table 3 category Measuring distance Test beam diameter mm Illuminance lx Light low light Average Minimum Average Minimum Wearable 2 150 >=450 >=300 >=200 >=150 Portable I type 5 300 >=250 >=150 >=150 >=100 II type 10 800 >=500 >=300 >=200 >=100
5.3.4 continuous and stable working time Lamps continuous and stable working hours shall comply with the requirements of Table 4. Table 4 in min. category Continuous and stable continuous working time working time under low voltage state Low light bright light low light Wearable >=240 >=480 Portable I type >=300 >=600 Type II >=560 >=840 >=15 >=30
5.3.5 low voltage alarm time Lamps low voltage alarm time should be 10s ~ 20s.
5.3.6 continuous working time at a low voltage condition Lamps at a low voltage state of continuous working hours shall comply with the requirements of Table 4.
5.3.7 insulation At room temperature environment, the insulation resistance between the shell and the lighting live terminal shall not be less than 20MOmega, after alternating hot and humid test shall not be less than 5MOmega.
5.3.8 withstand voltage performance Lamps should be able to withstand a frequency of 50Hz ± 0.5Hz, AC voltage 500V ± 50V, which lasted withstand voltage test of the 60s ± 5s. test Inspection procedure, the lamp should surface arcing and breakdown phenomenon. After the test, the lamp shall be able to be opened and closed strong, low light switch.
5.3.9 weatherability environmental performance Lamps should be able to withstand the test specified in Table 5 climate conditions. After each test, the lamp shall be able to be on, off and Strong, low-light switch. table
5 Test Project Name Test Parameters Test Conditions Sample status Low temperature performance High temperature performance temperature -25 ± 2 duration temperature 55 ± 2 duration Light work status Alternating hot and humid performance Cold storage High-temperature storage temperature 25 ±
5.3.8 Withstand voltage characteristic sqrt
5.3.9 Weather Environmental performance Low temperature performance sqrt High temperature performance sqrt Alternating hot and humid performance sqrt Cold storage sqrt High-temperature storage sqrt
5.3.10 Resistance to mechanical Environmental performance Anti-vibration (sinusoidal) Performance sqrt Anti-drop performance sqrt 18
6 Test methods
6.1 Test Environment If no special instructions related provisions, the test should be carried out under the following atmospheric conditions.
a) Temperature. 15 °C ~ 35 °C;
b) Relative humidity. 45% ~ 75%;
c) Atmospheric pressure. 86kPa ~ 106kPa.
6.2 Function Test
6.2.1 Operation lamp switch, check the strong lamps, low-light switching function.
6.2.2 The lighting at a low voltage state, flashes through sensory inspection lamps and low voltage alarm form.
6.3 Appearance and assembly inspection Observation through the senses, touch, appearance and assembly inspection operation.
6.4 Quality Measurement With an accuracy of not less than 1g of electronic scales measuring quality lamps.
6.5 illuminance measurement After the lamp is fully charged, in the dark (no light is completely sealed space) in the open light switch, after sustained 10min, respectively, in the lamp intensity Light, low light condition, as shown in Figure 1, in front of the press table lamp test specified distance of 3, along the direction of the beam diameter, with a distributed light meter The average illuminance distribution point on the measured value of 5 predetermined beam diameter. The arithmetic mean and minimum measurements taken
5.00 as the illuminance value.
6.6 continuous and stable work time test After discharge lamps, then full power, turn on the switch, respectively, in the lamp light, low light and with the state of the timer is started, press When the method of continuously measured and recorded
6.5 illuminance values fixture until it is less than the minimum specified in Table 3 illumination or appear low voltage warning status Stop timer. The time is the time to work for a stable fixture.
6.7 Low voltage alarm time trial After discharge lamps, then full power, turn on the switch, respectively, in the lamp light, low light condition, when the lamp in the light, low light status Under low voltage alarm occurs when, with a timer is started until the lamp flashes a low voltage alarm status and stop it when disappears. This time Room lighting is low voltage alarm time. Continuous working time test at
6.8 low voltage state In 20 consecutive times charge and discharge after the lamp is fully charged, turn on the switch, respectively, in the lamp light, low light condition, when the light fixture, Low voltage alarm state low light condition disappears with the timer is started, according to the method of continuously measured and recorded
6.5 lamp illumination Value until the timer is stopped when the illumination is less than the minimum specified in Table 3 it. The next time the lamp is a low voltage state of continuous work time. Explanation. 1
--- backplane; 2
--- distributed according to meter; 3
--- lamp bracket; 6
7 Inspection rules
7.1 Inspection classification The test fixture into the factory inspection and type testing.
7.2 factory inspection
7.2.1 factory inspection to every 100 pieces (sets) of a group, less than 100 (sets) the actual production capacity, each batch of randomly selected two (sets) Submit test.
7.2.2 factory inspection items should include at least 5.3.1,5.3.2,5.3.3,5.3.5,5.3.7,5.3.8,5.3.12. If a failure, then to Nonconforming items doubled sampling, if still fail to meet, the batch of lighting products factory inspection to be ineligible.
7.3 Type inspection
7.3.1 When one of the following conditions, type of inspection should be carried out.
a) new product trial stereotypes and old products to the plant;
b) There are major changes that may affect product performance and styling product materials, design, construction, technological aspects;
c) Product Discontinuance year to resume production;
d) the occurrence of major quality accidents.
7.3.2 type test sample should be factory inspection of products at random, the number of samples of three (sets).
7.3.3 type test items and test procedures shall be in accordance with Table 7.
7.3.4 type test results of the project complies with this standard, the contractor type inspection qualified. Table
8.1.2 Charger mark sqrt sqrt sqrt
Note. "sqrt" indicates that the item be tested. 8 signs, packaging, transportation and storage
8.1.1 Lamps Flag Position should have clear and obvious lighting and lighting as one of the signs, including the following.
a) the product name;
c) protection class (class IP66/IP68, the need to label diving depth and duration);
e) date of manufacture;
f) Product Code;
g) production plant name.
8.1.2 Charger logo Location charger should be clearly evident, durable signs, including the following.
a) the product name;
c) adaptation fixture type;
d) the date of manufacture;
f) the name of the production plant.
8.1.3 Package mark It shall be printed on the box obvious, clear, durable text signs, including the following.
a) Product name, model;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2423.1-2008 · GB/T 2423.2-2008 · GB/T 2423.4-2008 · GB/T 2423.10-2008 · GB 3836.1-2010 · GB 4208-2008 · GB 7000.1-2007
Similar standards
Editions of GB 30734
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 30734-2014 | Luminaires for firefighters | current edition | Current |
This page sells the current edition, GB 30734-2014. Earlier editions are listed for reference only.
How to Buy GB 30734-2014
- 1Add to cart. Click the "Buy GB 30734-2014" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 30734-2014
$150.00