GB 29989-2013Determination of L-carnitine in infant foods and dairy products (English PDF)
婴幼儿食品和乳品中左旋肉碱的测定
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB 29989-2013 in 30 minutes.
Issued by
National Health and Family Planning Commission of the People's Republic of China
Level / Type
National · Mandatory
Issue date
November 29, 2013
Implementation date
June 1, 2014
Scope
GB 29989-2013 is the English-translated version of 婴幼儿食品和乳品中左旋肉碱的测定.
GB 29989-2013 is the Chinese standard "Determination of L-carnitine in infant foods and dairy products". Its scope clause reads: This Standard specifies the method for determination of levocarnitine in foods and milk products for infants and young children.
This Standard is applicable to the determination of levocarnitine in foods and milk products for infants and young children. Its clauses include principle; reagents and materials; apparatuses and devices; analytical procedures; expression of analytical result; precision; other.
It was issued by the National Health and Family Planning Commission of the People's Republic of China on 2013-11-29 and took effect on 2014-06-01.
Found what you need?
Document preview — GB 29989-2013
National Standard of the People's Republic of China
Issued by: National Health and Family Planning Commission of the People's Republic of China
Contents
- 1 Scope...3
- 2 Principle...3
- 3 Reagents and Materials...3
- 4 Apparatuses and devices...5
- 5 Analytical Procedures...5
- 6 Expression of analytical result...6
- 7 Precision...6
- 8 Other...6
1 Scope
This Standard specifies the method for determination of levocarnitine in foods and milk products for infants and young children.
This Standard is applicable to the determination of levocarnitine in foods and milk products for infants and young children.
2 Principle
Extract the specimen with water; use perchloric acid to precipitate the protein; then filtrate it. After the filtrate is gone through alkaline saponification, the combined-state levocarnitine in solution is dissociated. Under the catalysis of carnitine acetyl transferase, levocarnitine reacts with acetyl coenzyme A to generate acetylcarnitine and free coenzyme A. Free coenzyme A reacts with 2-nitrobenzoic acid to generate yellow substance; the color of which is proportional to the content of free coenzyme A.
As the free coenzyme A and levocarnitine are of same mole reaction, the content of levocarnitine in specimen may be calculated indirectly.
3 Reagents and Materials
Note. Unless otherwise specified, all reagents adopted in this method are analytical reagents and the water is Grade 3 specified in GB/T 6682.
3.1 Reagents
3.1.1 Perchloric acid (HClO4).
3.1.6 Ethylenediamine tetraacetic acid disodium (C10H14N2Na2·2H2O).
3.1.7 Acetyl coenzyme A (AcetylCoA). kept under 2~8°C.
3.1.8 Carnitine acetyl transferase (CAT). kept under 2~8°C.
3.2 Reagent preparation
3.2.1 Perchloric acid solution (13%). dilute 13mL of perchloric acid to 100mL.
3.2.2 Sodium hydroxide solution (10mol/L). dissolve 40g of sodium hydroxide with
water; dilute to 100mL after cooling down.
3.2.3 Potassium hydroxide solution (4.0mol/L). dissolve 22.4g with water; dilute to
100mL after cooling down.
3.2.6 Acetyl coenzyme A (AcetylCoA) solution. dissolve 20.0mg of acetyl coenzyme
A into 2.0mL water. Prepare it just before use.
3.2.7 Carnitine acetyl transferase (CAT) solution. pipet 100µL of carnitine acetyl
transferase suspension; centrifuge it for 10min with rotation speed of 1500r/min;
discard the supernatant liquid and dissolve the sediment into 2mL of water. Prepare it just before use.
3.3 Standard product
Standard levocarnitine product (C7H15NO3). purity >=98%.
3.4 Preparation of standard solution
4 Apparatuses and devices
4.1 Analytical balance. with a sensitivity of 0.1mg.
4.2 pH meter. with a precision of 0.01.
4.5 Spectrophotometer.
5 Analytical Procedures
5.1 Specimen treatment
Accurately weigh 5g (accurate to 0.0001g) of well-mixed specimen; place it into a beaker; dissolve it with 30mL of 40°C warm water; transfer it into 100mL volumetric flask. Add 10mL of 13% perchloric acid solution into it; keep static for 20min after mixed uniformly. Fix the volume to the scale with distilled water; filter it with quantitative filter paper.
5.2 Drawing of standard curve
Pipet 2.0mL of standard levocarnitine working solution into a 1cm cuvette; add 0.8mL of color rendering working solution and 100µL of acetyl coenzyme A solution into it;
then cover it; after mixing it uniformly, put it in spectrophotometer;
5.3 Specimen determination
Take 2.0mL of specimen treatment solution; determine its absorbance according to the procedures specified in Section 5.2.Obtain the concentration of specimen solution to be tested through standard curve.
6 Expression of analytical result
The content X of levocarnitine in specimen is expressed by mass fraction mg/100g and calculated according to Formula (1).
7 Precision
The absolute deviation of two independent determination results under repeatability conditions shall not exceed 10% of arithmetic mean.
8 Other
Method detection limit is 0.6mg/100g; quantitation limit is 2mg/100g.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
How to Download GB 29989-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 29989-2013
$50.00