Valid

GB 29989-2013Determination of L-carnitine in infant foods and dairy products (English PDF)

婴幼儿食品和乳品中左旋肉碱的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (6 pages)

Need quotation for your management?

Get a formal quotation for GB 29989-2013 in 30 minutes.

Issued by

National Health and Family Planning Commission of the People's Republic of China

Level / Type

National · Mandatory

Issue date

November 29, 2013

Implementation date

June 1, 2014

Scope

GB 29989-2013 is the English-translated version of 婴幼儿食品和乳品中左旋肉碱的测定.

GB 29989-2013 is the Chinese standard "Determination of L-carnitine in infant foods and dairy products". Its scope clause reads: This Standard specifies the method for determination of levocarnitine in foods and milk products for infants and young children.

This Standard is applicable to the determination of levocarnitine in foods and milk products for infants and young children. Its clauses include principle; reagents and materials; apparatuses and devices; analytical procedures; expression of analytical result; precision; other.

It was issued by the National Health and Family Planning Commission of the People's Republic of China on 2013-11-29 and took effect on 2014-06-01.

Found what you need?

Document preview — GB 29989-2013

National Standard of the People's Republic of China

Issued by: National Health and Family Planning Commission of the People's Republic of China

Contents

  • 1 Scope...3
  • 2 Principle...3
  • 3 Reagents and Materials...3
  • 4 Apparatuses and devices...5
  • 5 Analytical Procedures...5
  • 6 Expression of analytical result...6
  • 7 Precision...6
  • 8 Other...6

1 Scope

This Standard specifies the method for determination of levocarnitine in foods and milk products for infants and young children.

This Standard is applicable to the determination of levocarnitine in foods and milk products for infants and young children.

2 Principle

Extract the specimen with water; use perchloric acid to precipitate the protein; then filtrate it. After the filtrate is gone through alkaline saponification, the combined-state levocarnitine in solution is dissociated. Under the catalysis of carnitine acetyl transferase, levocarnitine reacts with acetyl coenzyme A to generate acetylcarnitine and free coenzyme A. Free coenzyme A reacts with 2-nitrobenzoic acid to generate yellow substance; the color of which is proportional to the content of free coenzyme A.

As the free coenzyme A and levocarnitine are of same mole reaction, the content of levocarnitine in specimen may be calculated indirectly.

3 Reagents and Materials

Note. Unless otherwise specified, all reagents adopted in this method are analytical reagents and the water is Grade 3 specified in GB/T 6682.

3.1 Reagents

3.1.1 Perchloric acid (HClO4).

3.1.6 Ethylenediamine tetraacetic acid disodium (C10H14N2Na2·2H2O).

3.1.7 Acetyl coenzyme A (AcetylCoA). kept under 2~8°C.

3.1.8 Carnitine acetyl transferase (CAT). kept under 2~8°C.

3.2 Reagent preparation

3.2.1 Perchloric acid solution (13%). dilute 13mL of perchloric acid to 100mL.

3.2.2 Sodium hydroxide solution (10mol/L). dissolve 40g of sodium hydroxide with

water; dilute to 100mL after cooling down.

3.2.3 Potassium hydroxide solution (4.0mol/L). dissolve 22.4g with water; dilute to

100mL after cooling down.

3.2.6 Acetyl coenzyme A (AcetylCoA) solution. dissolve 20.0mg of acetyl coenzyme

A into 2.0mL water. Prepare it just before use.

3.2.7 Carnitine acetyl transferase (CAT) solution. pipet 100µL of carnitine acetyl

transferase suspension; centrifuge it for 10min with rotation speed of 1500r/min;

discard the supernatant liquid and dissolve the sediment into 2mL of water. Prepare it just before use.

3.3 Standard product

Standard levocarnitine product (C7H15NO3). purity >=98%.

3.4 Preparation of standard solution

4 Apparatuses and devices

4.1 Analytical balance. with a sensitivity of 0.1mg.

4.2 pH meter. with a precision of 0.01.

4.5 Spectrophotometer.

5 Analytical Procedures

5.1 Specimen treatment

Accurately weigh 5g (accurate to 0.0001g) of well-mixed specimen; place it into a beaker; dissolve it with 30mL of 40°C warm water; transfer it into 100mL volumetric flask. Add 10mL of 13% perchloric acid solution into it; keep static for 20min after mixed uniformly. Fix the volume to the scale with distilled water; filter it with quantitative filter paper.

5.2 Drawing of standard curve

Pipet 2.0mL of standard levocarnitine working solution into a 1cm cuvette; add 0.8mL of color rendering working solution and 100µL of acetyl coenzyme A solution into it;

then cover it; after mixing it uniformly, put it in spectrophotometer;

5.3 Specimen determination

Take 2.0mL of specimen treatment solution; determine its absorbance according to the procedures specified in Section 5.2.Obtain the concentration of specimen solution to be tested through standard curve.

6 Expression of analytical result

The content X of levocarnitine in specimen is expressed by mass fraction mg/100g and calculated according to Formula (1).

7 Precision

The absolute deviation of two independent determination results under repeatability conditions shall not exceed 10% of arithmetic mean.

8 Other

Method detection limit is 0.6mg/100g; quantitation limit is 2mg/100g.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

How to Download GB 29989-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 29989-2013

$50.00