GB 29218-2012National food safety standards -- Food additives -- Methanol (English PDF)
食品添加剂 甲醇
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB 29218-2012 in 30 minutes.
Issued by
Ministry of Health of the People's Republic of China
Level / Type
National · Mandatory
Issue date
December 25, 2012
Implementation date
January 25, 2013
Scope
GB 29218-2012 is the English-translated version of 食品添加剂 甲醇.
GB 29218-2012 — This standard applies to coal, natural gas, light oil, heavy oil as raw material for the production of food additives methanol.
Found what you need?
Document preview — GB 29218-2012
National Standard of the People's Republic of China
- ICS
- 67.220.20
- Classification
- X 40
Issued by: Ministry of Health of the People's Republic of China
Contents
- 1 Scope
- 2 Molecular formula and relative molecular mass
- 2.1 Molecular formula
- 2.2 Relative molecular mass
- 3 Technical requirements
- 3.1 Sensory requirements
- 3.2 Physical and chemical indicators
1 Scope
This standard applies to coal, natural gas, light oil, heavy oil as raw material for the production of food additives methanol.
2 Molecular formula and relative molecular mass
2.1 Molecular formula
CH3OH
2.2 Relative molecular mass
32.04 (according to 2007 International relative atomic mass)
3 Technical requirements
3.1 Sensory requirements
Shall comply with the provisions of Table 1.
Table 1 sensory requirements
The project requires a test method Color and colorless State transparent liquid Take appropriate sample, placed in a clean, dry colorimetric tube, in the self Under the light, observe the color and state
3.2 Physical and chemical indicators
Shall comply with the provisions of Table 2.
Table 2 Physical and chemical indicators
Item Index Test Method Methanol content, w /% >= 99.5 Appendix A, A.4 Moisture, w /% <= 0.1 GB 5009.3 Karl Fischer method Carbonyl compounds (in formaldehyde), w /% <= 0.010 GB/T 6324.5-2008 4.2a Distillation range/°C 64.5 ~ 65.5 GB/T 7534 Evaporation residue/(mg/100mL) <= 3 GB/T 6324.2
Table 2 (continued)
Item Index Test Method Acidity (in formic acid)/(mg/kg) <= 15 Appendix A A.5 Alkalinity (in ammonia)/(mg/kg) <= 3 Appendix A A.6 Lead (Pb)/(mg/kg) <= 2 GB 5009.12 a measurement wavelength of 430nm.
Appendix A
Testing method
A.1 Warning
The test procedure specifies that some of the test procedures may lead to dangerous conditions and that the operator should take appropriate safety and protective measures.
A.2 General provisions Unless otherwise stated, only the reagents identified as analytical reagents and the tertiary water specified in GB/T 6682-2008 are used in the analysis. test Method used in the standard titration solution, impurity determination standard solution, preparation and products, without any other requirements, according to GB/T 601, GB/T 602 and GB/T 603; the solution used in the absence of the solvent, refers to the aqueous solution.
A.3 Identification test A.3.1 Solubility Soluble in water, ether and ethanol.
A.3.2 Refractive index According to the provisions of GB/T 614 determination. Refractive index n (20, D) should be. 1.328 ~ 1.330.
A.3.3 Density
According to the provisions of GB/T 4472 to determine. The density (rho20) should be 0.790 g/cm3 to 0.793 g/cm3.
A.3.4 Boiling point
According to the method specified in GB/T 7534. The boiling point should be about 65 ° C.
A.4 Determination of methanol content A.4.1 Methodological Summary Under the selected working conditions, the samples were vaporized through the column, the components were separated and detected with a hydrogen flame ionization detector. use Determination of Methanol Content by Area Normalization Method.
A.4.2 Reagents and materials Calibration solution (mixed with methanol and 1,4-dioxane). 1 250.
A.4.3 Instruments and equipment A.4.3.1 Gas chromatograph. equipped with flame ionization detector, the machine sensitivity and stability in line with GB/T 9722 in the relevant provisions.
A.4.3.2 Recorder. Chromatographic data processor or chromatographic workstation.
A.4.3.3 Sampler. Microinjector.
A.4.4 Columns and Typical Chromatographic Operating Conditions the recommended column and typical chromatographic operating conditions are given in Table A.1. Other columns that can meet the analytical requirements and chromatographic operating conditions are also available use.
Table A.1 Recommended Columns and Typical Chromatographic Operating Conditions
Column
Column length 1.8m, column diameter 4mm, filler 105µm ~ 120µm benzene Ethylene - divinylbenzene polar monomer copolymer Column temperature/° C 160 Vaporization chamber temperature/°C.200 Detector temperature/°C 210 Carrier gas (nitrogen) Flow rate/(mL/min) 25 Injection volume/µL 5 ~ 10 A.4.5 Analysis steps the temperature of the mild (or) carrier gas of the regulator column is such that the retention time of the methanol is about 5 min to 7 min. Adjust the detector to make 8 µL of the calibration solution the resulting peaks are in the middle of the spectral range. Injection of 5µL ~ 10µL sample, to obtain the chromatogram, with the area normalization method Methanol content.
A.4.6 Calculation of results the mass fraction w1 of methanol is calculated according to formula (A.1) w1 = A1 sumAi × 100% (A.1) where.
A1 --- the peak area of methanol;
sumAi --- the sum of the peak areas of all components.
A.5 Determination of acidity (in form formic acid) A.5.1 Reagents and materials A.5.1.1 Ethanol.
A.5.1.2 Sodium hydroxide standard titration solution. c (NaOH) = 0.02 mol/L.
A.5.1.3 phenolphthalein indicator solution. 10g/L.
A.5.2 Analysis steps 10 mL of ethanol and 25 mL of water were mixed by adding 0.5 mL of phenolphthalein indicator solution, titrated with sodium hydroxide titration solution titrated to the first the pink appears and remains at least 30s. Add 19 mL (about 15 g) of the sample, mix and titrate the titration solution with sodium hydroxide standard until Times appear pink. Sodium hydroxide standard titration solution should be used in the amount of not more than 0.25mL.
A.6 Determination of alkalinity (in ammonia) A.6.1 Reagents and materials A.6.1.1 Sulfuric acid standard titration solution. c (1/2H2SO4) = 0.02 mol/L.
A.6.1.2 methyl red indicator solution. 1g/L.
A.6.2 Analysis steps Add 1 drop of methyl red indicator to 25 mL of water and titrate to red with standard titration solution of sulfuric acid. Add 29 mL (approx.
22.5 g) sample, mix well. Titration with sulfuric acid standard titration solution to red again, sulfuric acid standard titration solution should not be used at 0.2 mL.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
How to Download GB 29218-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 29218-2012
$90.00