GB 27899-2011 is the Chinese national standard on firemen's directional light, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 30 December 2011 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 June 2012. Classification: ICS 13.220.10, CCS C85. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB 27899-2011
National Standard of the People's Republic of China
- ICS
- 13.220.10
- Classification
- C85
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Models and basic parameters
- 5 Quality sqrt sqrt sqrt
- 5.1 Appearance and assembly quality
- 6 Test methods
- 7 Inspection rules
- 7.1 Type inspection
- 8.2 Packaging
Foreword
The standard Chapter 5, Chapters 7 and
8.1 are mandatory, the rest are recommended. This standard is prepared in accordance with GB/T 1.1-2009 given rules. The standard proposed by the People's Republic of China Ministry of Public Security. This standard by the National Standardization Technical Committee firefighters Fire Protection Equipment Technical Committee (SAC/TC113/SC12) centralized. This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security. Drafters of this standard. Shen Jian Min, Shixing Tang, Wu Yun, Rui Kun, Zhang Yan, Zhou Zhizhong. This standard is the first release. Fireman position lights
1 Scope
GB 27899-2011 is the Chinese national standard on firemen's directional light, in the field of environment and health protection, safety. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 30 December 2011 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 June 2012. Classification: ICS 13.220.10, CCS C85. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This standard specifies the terms and definitions firefighter position lights, model and basic parameters, technical requirements, test methods, inspection rules, marks, Packaging, transport and storage. This standard applies to the use of firefighters orientation light (hereinafter referred to as position lights).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packaging - Pictorial signs
GB/T 2423.1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold
GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat
GB/T 2423.3 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test
GB/T 2423.5 Environmental testing for electric and electronic products Part 2. Test methods Test Ea and guidance. Shock
GB/T 2423.10 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal)
GB 3836.1 explosive atmospheres - Part 1. General requirements for equipment
GB 4208-2008 shell protection (IP code)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Firemen position lights firemen'sdirectionallight Firefighters fire and rescue mission in the implementation of wear, with the light-emitting device signal indicating the orientation function.
3.2 Flash frequency flashfrequency The light emitting device in the position lights flashing times per unit time.
3.3 Continuous working time continuousworkingtime Maximum working time position lights lit or flashing state.
4 Models and basic parameters
4.1 Model Position lights Model preparation should meet the following requirements. R fireman personal equipment FWD Position lights - - Category Code / - Enterprises modified code (A, B)
4.2 position lights category code Position lights type code shown in Table 1. Table 1 position lamp category code Name Category Code Position lights flash type S Always position lights type C Always position lights flash type SC Example. RFWD-S/A represents A-type flash-based firefighters and position lights.
4.3 Basic parameters The basic parameters of position lights as follows:
a) working environment temperature -25 °C ~ 70 °C;
b) Relative humidity 30% to 85%;
c) Power supply rechargeable batteries should be used and should be set battery charge and discharge protection circuit.
5 Quality sqrt sqrt sqrt
6 Insulation Resistance sqrt sqrt sqrt 7 pressure resistance sqrt sqrt 8 protective properties sqrt sqrt Weather Environmental performance High temperature sqrt Low sqrt Damp sqrt 10 vibration resistance sqrt 11 impact resistance sqrt 12 anti-drop performance sqrt sqrt sqrt 13 explosion-proof performance sqrt 14 simulated smoke environment azimuth indicating performance sqrt 15 flag sqrt sqrt sqrt
Note. "sqrt" This sample represented by this test.
7.2 factory inspection
7.2.1 Each position lights shall be subject to factory inspection.
7.2.2 factory inspection of the project according to the provisions 5.1,5.2,5.3,
7.2.3 factory inspection results of the seized items all meet the requirements of this standard, in order to pass. 8 signs, packaging, transportation and storage
8.1 mark Position lights should be clear and durable signs include the following.
a) the product type and name;
b) production plant name;
c) the date of manufacture;
5.1 Appearance and assembly quality
5.1.1 position lamp surface should be no scratches, contamination, cracks, burrs and other defects. Signs should be clear, accurate, and complete.
5.1.2 orientation lamp assembly should be complete fastening parts should be no loose, injury, misalignment, burrs and other defects. Wearing the device should be flexible and reliable.
5.2 emission luminance Position lights brightness not less than 300cd/m2.
5.3 flash frequency Flash type position lights flash frequency should be 1Hz ~ 2Hz.
5.4 Continuous working time Position lights flash type continuous working time should not be less than 100h, position lights lit type continuous working time should not be less than 20h.
5.5 Quality Quality position lights should not exceed 150g.
5.6 Insulation resistance Position lights insulation resistance between the housing and the charging terminals shall not be less than 50MOmega, after the damp heat test the insulation resistance shall be not less than 10MOmega.
5.7 pressure resistance Position lights should be able to withstand a frequency of 50Hz ± 0.5Hz, voltage 500V ± 50V, pressure resistance test lasted for 60s ± 5s. test During surface arcing and breakdown should not occur. After the test, position lights should be able to work properly.
5.8 Housing protection performance Shell protection performance orientation of the lamp shall comply with the requirements specified in GB 4208-2008 of IP65.
5.9 weatherability environmental performance Position lights should be able to withstand the test under Table 2 under the climate conditions. After each test, position lights should be able to work properly. Table 2 weathering test environment Name of Test Test Parameters Test Conditions Operating status Hot test Temperature of 70 °C ± 2 °C Duration 2h Energized state Low temperature test Temperature -25 °C ± 2 °C Duration 2h Energized state Damp heat test Relative humidity of 82% to 85% Temperature of 40 °C ± 2 °C Duration 2h Energized state
5.10 Mechanical resistance to environmental performance Position lights should be able to withstand the test in Table 3 under specified mechanical environmental conditions. After each test, position lights should not have mechanical damage and tight Firmware loosening, and it can work normally. Table 3 resistance to mechanical environmental tests Name of Test Test Parameters Test Conditions Operating status Vibration (sinusoidal) test Frequency range of 10Hz ~ 55Hz 1g acceleration amplitude Sweep rate 1 octave/min Each axis scanning cycles
20 The vibration direction X, Y, Z Energized state Impact test Peak acceleration 5g 11ms pulse duration Half-sine pulse waveform Axial number
6 Test methods
6.1 Appearance and assembly quality inspection Visual inspection.
6.2 luminous intensity measurement Position lights brightness distribution of test points according to claim 1, with an accuracy not less than ± 5% of the luminance meter light-emitting surface in the azimuth 5m The distance measurement. Figure 1 position lamp brightness measurement diagram
6.3 Flash Frequency Measurement Open position lights make the switch work. With an accuracy of not less than 0.1s stopwatch time records in the 20s directional light emitting device number of flashes, Calculated flash frequency.
6.4 Continuous operating time test Open position lights make the switch work, while using the watch start time, until the position lights to stop the chronograph and read the time off.
6.5 Quality Measurement With an accuracy of not less than 1g electronic scale measuring position lights quality.
6.6 Insulation resistance test With an accuracy not less than ± 5% of the insulation resistance meter must measure the DC voltage between 500V position lamp housing and live terminals Insulation resistance.
6.7 pressure resistance test With an accuracy not less than ± 10% voltage test equipment between position lights external charging terminals and the case is applied to a frequency of 50Hz ± 5Hz, Voltage 500V ± 50V AC voltage, continuous 60s ± 5s.
6.8 shell protection performance test According to the test method specified in GB 4208-2008 carried out.
6.9 weatherability performance test environment
6.9.1 High-temperature test The orientation of the lamp into the high temperature test chamber, it is energized, the temperature was set at 70 °C ± 2 °C, holding 2h, press test The provisions of GB/T 2423.2 performed.
6.9.2 Low Temperature Test The position lights placed low temperature test chamber, it is energized, the temperature is set at -25 °C ± 2 °C, holding 2h, press test The provisions of GB/T 2423.1 performed.
6.9.3 Damp heat test The orientation of the lamp into the constant heat chamber, and it is in power-on state. Adjusting the temperature to 40 °C ± 2 °C, after the temperature was stabilized, and then transferred Section of the chamber relative humidity to 82% to 85%, keeping 2h. Test according to the provisions of GB/T 2423.3 performed.
6.10 vibration resistance test The position lights fixed vibration table, according to the provisions of
5.10 vibration (sinusoidal) test conditions and GB/T 2423.10 performed.
7.1 Type inspection
7.1.1 When one of the following conditions, type of inspection should be carried out.
a) production of new products or old products to the plant production trial when stereotypes;
b) after the operation there is a greater change in the product mix, the main components, production processes, may affect product performance;
c) three years after the commissioning of continuous production;
d) Product Discontinuance more than one year, the production recovery;
e) factory test results and the last type test results differs considerably;
f) the occurrence of major quality accidents;
g) the national quality supervision agency when requested.
7.1.2 Type inspection items according to the provisions of Section 5 and 8.1.
7.1.3 type test samples for three. Provisions of the test sequence
7.1.4 type inspection of Table 4. Results
7.1.5 type inspection items all satisfy the requirements of this standard, in order to pass. Table 4 test sequence type test Test Procedure Sample No. Item No. 123 pilot projects
1 Appearance and assembly quality sqrt sqrt sqrt 2 emission luminance sqrt sqrt sqrt 3 flash frequency sqrt sqrt sqrt 4 continuous working hours sqrt sqrt
8.2 Packaging
8.2.1 position lights package Pictorial signs should be consistent with the provisions of GB/T 191's.
8.2.2 position lights should be packing factory, and a moisture-proof, dust-proof measures.
8.2.3 The outer box should be obvious, durable word mark, should include the following.
a) production plant name;
b) the product type and name;
c) the date of manufacture;
d) up, afraid of wet, handle with care and other words or symbols.
8.2.4 document accompanying the product should include the following.
a) product certification;
b) the product manual.
8.3 Transport Position lights during transport due precautions rain and snow, to avoid stress and impact.
8.4 Storage Position lights should be kept in ventilated, dry warehouse and no harmful gases, corrosive chemicals should not be stored together.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2423.1 · GB/T 2423.2 · GB/T 2423.3 · GB/T 2423.5 · GB/T 2423.10 · GB 3836.1 · GB 4208-2008
Similar standards
Editions of GB 27899
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 27899-2011 | Firemen's directional light | current edition | Current |
This page sells the current edition, GB 27899-2011. Earlier editions are listed for reference only.
How to Buy GB 27899-2011
- 1Add to cart. Click the "Buy GB 27899-2011" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 3836.15-2024 — Explosive atmospheresPart 15: Specification of electrical installations design, selection and erection
GB 3836.16-2024 — Explosive atmospheres - Part 16: Specification of electrical installations inspection and maintenance
GB/T 191-2025 — Graphical symbols marking for handling and storage of packages
Secure payment via Stripe
Payments accepted
GB 27899-2011
$140.00