Scope

GB 25466-2010 is the English-translated version of 铅、锌工业污染物排放标准.

GB 25466-2010 — This Standard specifies the emission limits, surveillance and monitoring requirements for water pollutants and atmospheric pollutants in lead and zinc industrial enterprises, as well as relevant provisions on implementation and supervision of standard.

This Standard is applicable to the management of water pollutants and atmospheric pollutants in lead and zinc industrial enterprises, as well as environmental impact assessment, environmental protection facilities design, and environmental protection acceptance of lead and zinc industrial enterprises construction projects as well as the management of water pollutants and atmospheric pollutants after they are put into production.

This Standard does not apply to industries such as calendering of recycled lead, recycled zinc and lead timber, zinc timber. It is not applicable to non- characteristic production processes and devices affiliated with lead and zinc industrial enterprises.

This Standard applies to the discharge of pollutants permitted by law.

For site selection of newly established pollution sources and management of existing pollution sources in special protection areas, in addition to this Standard, it shall also comply with the relevant provisions of laws, regulations and rules such as the Law of the People's Republic of China on Prevention and Control of Atmospheric Pollution, the Law of the People's Republic of China on Prevention and Control of Water Pollution, the Law of the People's Republic of China on Marine Environmental Protection, the Law of the People's Republic of China on the Prevention and Control of Environmental Pollution of Solid Wastes, the Environmental Impact Assessment Law of the People's Republic of China.

The water pollutant emission control requirements specified in this Standard are applicable to the behavior of enterprises directly or indirectly discharging water pollutants outside their legal boundaries.

Found what you need?

Document preview — GB 25466-2010

National Standard of the People's Republic of China

ICS
发布日期
Classification
Z61

Issued by: Ministry of Ecology and Environment

Contents

  • Announcement of Ministry of Environmental Protection of PRC...2
  • Foreword...5
  • 1 Scope...7
  • 2 Normative references...7
  • 3 Terms and definitions...10
  • 4 Pollutant emission control requirements...11
  • 5 Pollutant monitoring requirements...17
  • 6 Implementation and supervision...21
  • Modification List 2013XG1...22

Foreword

To implement the Environmental Protection Law of the People's Republic of

China, the Law of the People's Republic of China on Prevention and Control of

Water Pollution, the Law of the People's Republic of China on Prevention and

Control of Atmospheric Pollution, the Law of the People's Republic of China on

Marine Environmental Protection, and the State Council on Strengthening the

Environment Laws and Regulations on Protection and other "Opinions of the

State Council on the Preparation of National Main Functional Area Planning",

to protect the environment, to prevent pollution, to promote the progress of lead

and zinc industrial production processes and pollution control technologies, this

Standard was formulated.

This Standard specifies the emission limits, monitoring and monitoring

requirements for water pollutants and atmospheric pollutants in the production

process of lead and zinc industrial enterprises. It is applicable to water pollution

and air pollution prevention and management in lead and zinc industrial

enterprises. In order to promote the coordinated development of regional

economy and environment, promote the adjustment of economic structure and

the transformation of economic growth mode, and guide the development

direction of lead and zinc industrial production processes and pollution control

technologies, this Standard specifies particular emission limits for water

pollutants.

The pollutant discharge concentration in this Standard is the mass

concentration.

Lead and zinc industrial enterprises emit odorous pollutants and environmental

noises. The identification, treatment and disposal of solid wastes are applicable

to national solid waste pollution control standards.

This Standard shall be issued for the first time.

From the date of implementation of this Standard, the discharge of water and

atmospheric pollutants from lead and zinc industrial enterprises shall comply

with this Standard. It shall not comply with relevant provisions in "Integrated

Wastewater Discharge Standard" (GB 8978-1996), "Comprehensive emission

standard of atmospheric pollutants" (GB 16297-1996) and "Standard of smoke

and dust emission for industrial kiln and furnace" (GB 9078-1996).

Local provincial people's governments may formulate local pollutant discharge

standards for pollutants not specified in this Standard. For pollutants that have

been stipulated in this Standard, local pollutant discharge standards that are

stricter than this Standard may be formulated.

Emission standard of pollutants

for lead and zinc industry

1 Scope

This Standard specifies the emission limits, surveillance and monitoring

requirements for water pollutants and atmospheric pollutants in lead and zinc

industrial enterprises, as well as relevant provisions on implementation and

supervision of standard.

This Standard is applicable to the management of water pollutants and

atmospheric pollutants in lead and zinc industrial enterprises, as well as

environmental impact assessment, environmental protection facilities design,

and environmental protection acceptance of lead and zinc industrial enterprises

construction projects as well as the management of water pollutants and

atmospheric pollutants after they are put into production.

This Standard does not apply to industries such as calendering of recycled lead,

recycled zinc and lead timber, zinc timber. It is not applicable to non-

characteristic production processes and devices affiliated with lead and zinc

industrial enterprises.

This Standard applies to the discharge of pollutants permitted by law. For site

selection of newly established pollution sources and management of existing

pollution sources in special protection areas, in addition to this Standard, it shall

also comply with the relevant provisions of laws, regulations and rules such as

the Law of the People's Republic of China on Prevention and Control of

Atmospheric Pollution, the Law of the People's Republic of China on Prevention

and Control of Water Pollution, the Law of the People's Republic of China on

Marine Environmental Protection, the Law of the People's Republic of China on

the Prevention and Control of Environmental Pollution of Solid Wastes, the

Environmental Impact Assessment Law of the People's Republic of China.

The water pollutant emission control requirements specified in this Standard

are applicable to the behavior of enterprises directly or indirectly discharging

water pollutants outside their legal boundaries.

2 Normative references

This Standard refers to the following documents or their terms.

HJ/T 195-2005, Water quality - Determination of ammonia-nitrogen Gas-

phase molecular absorption spectrometry

HJ/T 199-2005, Water quality - Determination of total-nitrogen Gas-phase

molecular absorption spectrometry

HJ/T 399-2007, Water quality - Determination of the chemical oxygen

demand - Fast digestion - Spectrophotometric method

HJ 482-2009, Ambient air - Determination of sulfur dioxide - Formaldehyde

absorbing-pararosaniline spectrophotometry

HJ 483-2009, Ambient air - Determination of sulfur dioxide in ambient air -

Tetrachloromercurate (TCM) - pararosiniline method

HJ 487-2009, Water quality - Determination of Fluoride - Visual colorimetry

zirconium alizarin sulfonate

HJ 488-2009, Water quality - Determination of Fluoride - Fluorine reagents

spectrophotometry

HJ 535-2009, Water Quality - Determination of Ammonia Nitrogen - Nesslers

Reagent Spectrophotometry

HJ 536-2009, Water quality - Determination of ammonia nitrogen - Salicylic

acid spectrophotometry

HJ 537-2009, Water quality - Determination of ammonia nitrogen - Distillation

- neutralization titration

HJ 538-2009, Stationary source emission - Determination of lead - Flame

atomic absorption spectrometry (on trial)

HJ 539-2009, Ambient air. Determination of lead. Graphite furnace atomic

absorption spectrometry (on trial)

HJ 542-2009, Ambient air - Determination of mercury and its compounds -

Cold atomic fluorescent (on trial)

HJ 543-2009, Stationary source emission - Determination of mercury - Cold

atomic absorption spectrophotometry (on trial)

HJ 544-2009, Stationary source emission - Determination of sulfuric acid

mist-Ion chromatography (on trial)

Measures for the Automatic Monitoring and Control of Pollution Sources

(Order No. 28 of the State Environmental Protection Administration)

Measures for the Administration of Environmental Monitoring (Order No. 39

3.8 standard condition

referring to the state when the temperature is 273.15 K and the pressure is 101

325 Pa; the atmospheric pollutant emission concentration limits specified in this

Standard are based on dry gas under standard conditions

3.9 excess air coefficient

referring to the ratio of actual air volume to theoretical air demand during

industrial furnace operation

3.10 enterprise boundary

referring to the legal boundary of lead and zinc industrial enterprises; if the

boundary cannot be determined, it means the actual boundary

3.11 public wastewater treatment system

referring to enterprises or institutions that collect wastewater through sewage

pipelines, provide wastewater treatment services to more than two pollutant

discharge units, and discharge to meet relevant emission standards, including

urban sewage treatment plants of various scales and types, regional (including

various industrial parks, development zones, industrial agglomerations, etc.)

wastewater treatment plants, etc., of which the degree of wastewater treatment

shall reach level two or more

3.12 direct discharge

referring to the behavior of pollutant discharge units directly discharging water

pollutants into the environment

3.13 indirect discharge

referring to the behavior of pollutant discharge units discharging water

pollutants into public sewage treatment systems

4 Pollutant emission control requirements

4.1 Control requirements for water pollutant emission

4.1.1 From January 1, 2011 to December 31, 2011, existing facility shall

implement the water pollutant emission limits specified in Table 1.

as the basis for determining whether the emission meets the standard

requirements. The product production and effluent volume statistics period is

one working day.

In the case of producing two or more products at the same time in the

production facilities of the enterprise, when it is applicable to different emission

control requirements or national pollutant emission standards of different

industries, and the sewage generated by the production facilities is mixed and

discharged, the most stringent concentration limits specified in the emission

standards shall be implemented. And the benchmark effluent volume emission

concentration of water pollutant shall be converted according to formula (1).

where,

rhobenchmark - the benchmark effluent volume emission concentration of water

pollutant, mg/L;

Qtotal - the total drainage, m3;

Yi - the yield of the ith kind of product, t;

Qi benchmark - the benchmark effluent volume per unit product of the ith kind of

product, m3/t;

rhomeasured - the measured concentration of water pollutant, mg/L.

If the ratio of Qtotal to sumYi·Qi benchmark is less than 1, then use the measured

concentration of water pollutant as the basis for determining whether the

emission meets the standard requirements.

4.2 Control requirements for atmospheric pollutant emission

4.2.1 From January 1, 2011 to December 31, 2011, existing facility shall

implement the atmospheric pollutant emission limits specified in Table 4.

rhobenchmark Qtotal

sumYi·Qi benchmark

rhomeasured

Table 6 -- Atmospheric pollutant concentration limits at enterprise

boundary of existing and new facilities

mg/m3

No. Pollutant item Maximum concentration limit

1 Particulates 0.5

2 Sulfur dioxide 1.0

3 Sulfuric acid mist 0.3

4 Lead and its compounds 0.006

5 Mercury and its compounds 0.0003

4.2.5 In the production process after the completion of environmental protection

acceptance of existing facility production and construction projects, the

environmental protection department in charge of supervision shall monitor the

environmental quality of sensitive areas around the residential, teaching,

medical and other uses. The specific monitoring scope of the construction

project is the surrounding sensitive area determined by the environmental

impact assessment. For existing facility that has not conducted environmental

impact assessment, the scope of monitoring shall be determined by the

competent environmental protection department in charge of supervision,

according to the characteristics and laws of the facility's sewage discharge and

local natural and meteorological conditions, etc., with reference to the relevant

environmental impact assessment technical guidelines. The local government

shall be responsible for the environmental quality of its jurisdiction and take

measures to ensure that the environmental conditions meet the requirements

of environmental quality standards.

4.2.6 The production processes and devices that produce atmospheric

pollutants must establish local or integral gas collection systems and

centralized purification treatment devices. All stack height shall be no less than

15 m. When there are buildings within a radius of 200 m around the stack, the

stack height shall be higher than the maximum height by more than 3 m.

4.2.7 The lead and zinc smelting furnaces have an excess air ratio of 1.7. The

measured pollutant emission concentration of lead and zinc smelting furnaces

shall be converted into the benchmark excess air coefficient emission

concentration. Production facilities shall adopt reasonable ventilation measures.

Do not intentionally dilute emissions. Before the country does not stipulate the

benchmark exhaust volume of other production facilities, the actual measured

concentration shall be used as the basis for determining whether it meets the

standard.

5 Pollutant monitoring requirements

5.1 General requirements for pollutant monitoring

14 Total arsenic

Water quality - Determination of total arsenic

- Silver diethyldithiocarbamate

spectrophotometric method

GB/T 7485-1987

15 Total nickel

Water quality - Determination of nickel -

Flame atomic absorption spectrometric

method

GB/T 11912-1989

16 Total chromium Water quality. Determination of total chromium GB/T 7466-1987

5.3 Atmospheric pollutant monitoring requirements

5.3.1 The sampling point setting and sampling method are performed according

to GB/T 16157-1996.

5.3.2 Unorganized emission monitoring in the presence of sensitive buildings

and where necessary are monitored according to HJ/T 55-2000.

5.3.3 The measurement of the concentration of atmospheric pollutants emitted

by enterprises is based on the method standards listed in Table 8.

Table 8 -- Standards for determination methods of water pollutant

concentration

No. Pollutant item Standard name of method Reference to standard

1 Particulates

The determination of particulates and

sampling methods of gaseous pollutants

emitted from exhaust gas of stationary source

GB/T 16157-1996

Ambient air - Determination of total suspended

particulates - Gravimetric method GB/T 15432-1995

2 Sulfur dioxide

Determination of sulphur dioxide from

exhausted gas of stationary source Iodine

titration method

HJ/T 56-2000

Determination of Sulphur Dioxide from

Exhausted Gas of Stationary Source - Fixed-

potential Electrolysis Method

HJ/T 57-2000

Ambient air - Determination of sulfur dioxide -

Formaldehyde absorbing-pararosaniline

spectrophotometry

HJ 482-2009

Ambient air - Determination of sulfur dioxide in

ambient air -Tetrachloromercurate (TCM) -

pararosiniline method

HJ 483-2009

3 Sulfuric acid mist

Stationary source emission - Determination of

sulfuric acid mist-Ion chromatography (on trial) HJ 544-2009

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

How to Download GB 25466-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 25466-2010

$90.00