Superseded

GB 22255-2014National Food Safety Standard -- Determination of Sucralose in Foods (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for GB 22255-2014 in 30 minutes.

Issued by

National Health and Family Planning Commission

Level / Type

National · Mandatory

Issue date

January 28, 2015

Implementation date

July 28, 2015

Scope

GB 22255-2014 (National Food Safety Standard -- Determination of Sucralose in Foods) is available as an English-translated PDF.

GB 22255-2014 is the Chinese standard "National Food Safety Standard -- Determination of Sucralose in Foods". Its scope clause reads: This standard specifies the method for the determination of sucralose in food.

This standard applies to the determination of sucralose in food. Its clauses include principle; reagents and materials; instruments and equipment. It was issued by the National Health and Family Planning Commission on 2015-01-28 and took effect on 2015-07-28.

Found what you need?

Document preview — GB 22255-2014

National Standard of the People's Republic of China

Issued by: National Health and Family Planning Commission

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Principle...4
  • 3 Reagents and materials...4
  • 4 Instruments and equipment...5
  • 5 Analytical procedures...6
  • 6 Presentation of analysis results...9
  • 7 Precision...9
  • 8 Others...9

1 Scope

This standard specifies the method for the determination of sucralose in food.

This standard applies to the determination of sucralose in food.

2 Principle

The sucralose in the specimen is extracted by methanol aqueous solution, to remove protein and fat; then purified and enriched by solid phase extraction column; separated by high performance liquid chromatography and reversed phase C18 chromatographic column; detected by evaporative light scattering detector or differential detector;

qualified according to the retention time and quantified according to peak area.

3 Reagents and materials

Note: Unless otherwise specified, the reagents used in this method are of analytical grade; the water is the grade-1 water specified in GB/T 6682.

3.1 Reagents

3.1.1 Methanol (CH3OH).

3.1.2 Acetonitrile (CH3CN): Chromatographically pure.

3.1.3 n-Hexane (C6H14).

3.1.4 Zinc acetate [Zn(CH3COO)2·2H2O].

3.1.5 Potassium ferrocyanide [K4Fe(CN)6·3H2O].

3.1.6 Neutral alumina (100 mesh ~ 200 mesh).

3.2 Preparation of reagents

3.2.1 Zinc acetate solution (219 g/L): Weigh 21.9 g of zinc acetate. Add 3 mL of acetic acid. Add water to dissolve it to 100 mL.

3.2.2 Potassium ferrocyanide solution (106 g/L): Weigh 10.6 g of potassium

ferrocyanide. Add water to dissolve to 100 mL.

3.2.3 Methanol aqueous solution (75 + 25): Measure 75 mL of methanol. Add 25 mL of water. Mix well.

3.2.4 Acetonitrile aqueous solution (11 + 89): Measure 11 mL of acetonitrile. Add 89 mL of water. Mix well.

3.3 Standards

Sucralose standard (C12H19C13O8): CAS No. 56038-13-2, purity >= 99%.

3.4 Preparation of standard solution

3.4.1 Standard stock solution of sucralose (10.0 mg/mL): Weigh 0.25 g (accurate to

0.0001 g) of sucralose standard product, in a 25 mL volumetric flask. Use water to dilute to the mark. Mix well. The concentration of sucralose is 10.0 mg/mL. The stock solution is stored in a refrigerator at 4 °C. The shelf life is 6 months.

3.4.2 Standard intermediate solution of sucralose (1.00 mg/mL): Pipette 5.00 mL of

sucralose standard stock solution, into a 50 mL volumetric flask. Use water to dilute it to the mark. Mix well. The concentration of sucralose is 1.00 mg/mL. It is stored in a refrigerator at 4 °C. The shelf life is 3 months.

3.4.3 Standard working solution of sucralose: Pipette 0.200 mL, 0.500 mL, 1.00 mL,

2.00 mL, 4.00 mL of sucralose intermediate solution, into a 10 mL volumetric flask.

Use water to dilute to the mark. The concentration of sucralose working solution is

0.0200 mg/mL, 0.0500 mg/mL, 0.100 mg/mL, 0.200 mg/mL, 0.400 mg/mL, respectively.

3.5 Materials

Solid-phase extraction cartridges (200 mg, type N-vinylpyrrolidone and divinylbenzene hydrophilic-lipophilic balanced packing) are activated, by 4 mL of methanol and 4 mL of water sequentially, before use.

4 Instruments and equipment

4.1 High performance liquid chromatography: Equipped with a differential detector or

an evaporative light scattering detector.

4.2 Balance: Sensitivity is 0.1 mg and 1 mg.

4.3 Vortex mixer.

4.4 Centrifuge: speed >= 3000 r/min.

Weigh 2 g of the mixed specimen (accurate to 0.001 g). Put it in a 50 mL centrifuge tube. Add 1.0 g of neutral alumina. Add 3 mL of water. Oscillate it on a vortex mixer for 3 min. Then add 15 mL of methanol. The following steps are same as from 5.1.1.1

"Continue to oscillate for 30 s. Ultrasonically extract for 20 min. Centrifuge at 3000 r/min for 10 min", to 5.1.1.3 "The filtrate is the prepared specimen solution, which is set aside".

5.1.3 Alcohol-containing specimens (fermented wine, blended wine)

Weigh 5 g of the mixed specimen (accurate to 0.001 g). Place it in a 50 mL evaporating dish. Evaporate to dryness on a boiling water bath. Use 1.00 mL of acetonitrile aqueous solution (11 + 89), to dissolve the residue. Make the solution pass through a 0.45 µm filter membrane. The filtrate is the prepared specimen solution, which is set aside.

5.1.4 Beverages

Weigh 5 g of the mixed specimen (accurate to 0.001 g). Place it in a 15 mL centrifuge tube. Add 5 mL of water. Oscillate on a vortex mixer for 30 s. Centrifuge at 3000 r/min for 10 min. The following steps are processed according to 5.1.1.3.

5.1.5 Flavored fermented milk and milk tea

Weigh 1 g ~ 5 g of the mixed specimen (accurate to 0.001 g). Place it in a 50 mL centrifuge tube. Add 5 mL of water. Oscillate on a vortex mixer for 3 min. Then add 15 mL of methanol, 0.50 mL of zinc acetate solution, 0.50 mL of potassium ferrocyanide solution. The following steps are same as from 5.1.1.1 "Continue to oscillate for 30 s.

Ultrasonically extract for 20 min. Centrifuge at 3000 r/min for 10 min", to 5.1.1.3 "The filtrate is the prepared specimen solution, which is set aside".

The pretreatment of different specimens requires a specimen blank test at the same time.

5.2 Instrument reference conditions

5.2.1 Chromatographic column: C18 column (4.6 mm × 150 mm, 5 µm) or equivalent performance.

5.2.2 Mobile phase: water + acetonitrile = 89 + 11.

Note: When the detection sample matrix is complex AND the strongly retained substances affect the subsequent detection, an elution procedure can be adopted (applicable to evaporative light scattering detectors), as shown in Appendix A.

5.2.3 Flow rate: 1.0 mL/min.

5.2.4 Column temperature: 35 °C.

5.2.5 Differential detector conditions:

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

How to Download GB 22255-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 22255-2014

$45.00