Scope

GB 1903.44-2020 is the English-translated version of 食品安全国家标准 食品营养强化剂 羟钴胺.

GB 1903.44-2020 is the Chinese standard "National food safety standard - Food Nutritional Fortification Substance - Hydroxocobalamin". Its scope clause reads: This Standard is applicable to the food nutritional fortification substance hydroxocobalamin, which is produced by the fermentation method of Ensifer adhaerens through purifying and drying. Its clauses include molecular formula, structural formula and relative.

Found what you need?

Document preview — GB 1903.44-2020

National Standard of the People's Republic of China

Issued by: National Health Commission and State Administration for Market Regulation

Contents

  • 1 Scope3
  • 2 Molecular Formula, Structural Formula and Relative Molecular Mass3
  • 3 Technical Requirements4
  • Appendix A Test Methods5
  • Hydroxocobalamin15

1 Scope

This Standard is applicable to the food nutritional fortification substance hydroxocobalamin, which is produced by the fermentation method of Ensifer adhaerens through purifying and drying.

2 Molecular Formula, Structural Formula and Relative

Molecular Mass

2.1 Molecular formula

C62H89CoN13O15P

2.2 Structural formula

2.3 Relative molecular mass

1346.38 (according to 2018 international relative atomic mass)

Appendix A

Test Methods

A.1 General rules

Unless otherwise specified, only reagents confirmed to be analytically pure and Class-

1 water specified in GB/T 6682 are used in the analysis. The standard titration solutions, standard solutions for impurity determination, preparations and products that are used in the test methods shall be all prepared in accordance with the provisions of GB/T 601 and GB/T 602, when other requirements are not specified. The used solution refers to an aqueous solution when it is not specified which solvent is used for preparation.

A.2 Identification test

A.2.1 Reagents and solutions

A.2.1.1 Potassium bromide.

A.2.1.2 Potassium pyrosulfate.

A.2.1.3 Hydrochloric acid.

A.2.1.4 Glacial acetic acid.

A.2.1.5 Sodium acetate.

A.2.1.6 Phenolphthalein indicator solution

0.1g of phenolphthalein is dissolved in 95% ethanol and make a constant volume to 100mL.

A.2.1.7 Sodium hydroxide solution

2mol/L. Take 40g of sodium hydroxide; dissolve in water and make constant volume to 500mL.

A.2.1.8 Acetic acid solution

1mol/L. Pipette 58.8mL of glacial acetic acid in a 1L volumetric flask and make constant volume by water.

A.2.1.9 1-nitroso-2-naphthol-3,6-disulfonate sodium solution: Dissolve 1g of 1-nitroso-

2-naphthol-3,6-disulfonate sodium in an appropriate amount of water; transfer to a

100mL volumetric flask and make constant volume with water.

A.2.2 Infrared spectra analysis

The infrared spectra analysis is performed according to 5.2.2 of GB/T 6040-2002. The infrared absorption spectrum of the specimen shall be consistent with the standard spectrum of hydroxocobalamin hydrochloride. The standard infrared spectrum of hydroxocobalamin hydrochloride is shown in Figure B.1 of Appendix B.

A.3.2.8 Standard solution

According to the purity conversion, accurately take an appropriate amount of hydroxocobalamin hydrochloride standard product to make it contain hydroxocobalamin hydrochloride 0.02g, accurate to 0.0001g. And use the diluent (A.3.2.7) to dilute it into a 200mL volumetric flask; then make constant volume and use it as a standard solution. Filter it by a 0.45µm microporous membrane before use. Parallel specimens are required.

A.3.2.9 Specimen solution

Accurately take 0.02g (calculated according to the sum of the moisture and residual solvent) of the specimen, accurate to 0.0001g; and use the diluent (A.3.2.7) to dissolve and make constant volume to 200mL as the specimen solution; filter with 0.45µm microporous membrane before use. Parallel specimens are required.

A.3.3 Apparatus

A.3.3.1 Electronic balance with a sensitivity of 0.1 mg.

A.3.3.2 High performance liquid chromatograph.

A.3.4 Reference chromatographic conditions
A.3.4.1 Detector

UV detector or diode array detector.

A.3.4.2 Detection wavelength

351nm.

A.3.4.3 Chromatographic column

Take two columns of alkoxy silica gel (column length

10cm, inner diameter 4.6mm, large pores 2µm, mesopores 13nm) with extremely high purity as fillers connected in series or equivalent columns.

A.3.4.4 Column temperature

30°C.

A.3.4.5 Sampling volume

20µL.

A.3.4.6 Mobile phase

A is methanol, B is buffer solution (A.3.2.6), and C is water. The gradient elution conditions are shown in Table A.1.

- peak area of standard solution;

CU - concentration of hydroxocobalamin in the specimen solution, in mg/mL;

- molar mass of hydroxocobalamin hydrochloride, 1382.8, in g/mol.

A.3.8 Precision

The absolute difference between two independent determination results obtained under repeatability conditions shall not exceed 2% of its arithmetic mean.

A.4 Determination of related substances (by anhydrous and solvent-free)

A.4.1 Reagents and solutions
A.4.1.1 Methanol

chromatographically pure.

A.4.1.2 Sodium dihydrogen phosphate (NaH2PO4·12H2O).

A.4.1.3 Phosphoric acid.

A.4.1.4 Buffer solution

Take 15.6g of sodium dihydrogen phosphate; pour it into a

1000mL volumetric flask through a funnel; add a small amount of water to dissolve;

and add water to the mark. Shake well, filter through 0.45µm microporous membrane;

adjust the pH to 3.0 with 1:100 phosphoric acid solution; and put it in an ultrasonic water bath to degas for 10min.

A.4.1.5 Specimen dissolving solution

Accurately measure 820mL of water filtered through a 0.45µm microporous filter membrane; take 100mL of buffer solution (A.4.1.4) and 80mL of methanol to mix; shake well; and put it in an ultrasonic water bath to degas for 10min.

A.4.1.6 System suitability solution

0.75mg/mL. After conversion of purity, accurately take an appropriate amount of hydroxocobalamin hydrochloride standard product (A.3.2.4), and dissolve it by the specimen dissolving solution (A.4.1.5) to a 50mL volumetric flask; make the concentration is 0.75mg/mL as the system suitability solution.

A.4.1.7 Quantitative solution

7.5µg/mL. Respectively accurately pipette 0.5mL of the system suitability solution (A.4.1.6); and use the specimen dissolving solution (A.4.1.5) to dissolve and make constant volume to a 50mL volumetric flask.

A.4.1.8 Limited solution

0.75µg/mL. Accurately pipette 5mL of a quantitative solution (A.4.1.7); and dissolve with the specimen solution (A.4.1.5) and make constant volume to a 50 mL volumetric flask as the limited solution.

A.4.1.9 Specimen solution

0.75mg/mL. Accurately take 0.0375g (after calculating

A.5.4 Reference chromatographic conditions
A.5.4.1 Chromatographic column

Capillary column (30m×0.53mm×3.0µm, the fixative solution is 6% cyanopropyl phenyl-94% polydimethylsiloxane), or equivalent column.

A.5.4.2 Column temperature

40°C, keep 13min.

A.5.4.3 Detector temperature

250°C; inlet temperature: 140°C.

A.5.4.4 Carrier gas

N2; column flow: 4mL/min; air flow: 400mL/min; hydrogen flow:

60mL/min; makeup gas flow: 25mL/min; split ratio: 2:1.

A.5.4.5 Sampling mode

Headspace injection, with an injection volume of 1.0mL.

A.5.4.6 Conditions of headspace sampler

Headspace bottle equilibrium temperature

80°C, equilibrium time 60 min; temperature of quantitative loop 100°C; temperature of transfer line 100°C.

A.5.5 System suitability test

Carry out the system suitability test before the specimen test; use the acetone standard use solution (A.5.2.2) for 5 consecutive injections for repeatability test; and calculate the relative standard deviation (RSD) of the peak area. The relative standard deviation (RSD) of repeatability test is required to be no more than 10.0%. At the same time, record the number of theoretical plates of the acetone peak in the first injection of acetone standard use solution (A.5.2.2). The number of theoretical plates shall be no less than 5000. After the conditions are met, the normal test of the specimen is carried out; if it is not met, the system suitability test is continued after the cause is found out, and the specimen test is carried out after passing the system suitability test. Take the acetone standard use solution (A.5.2.2) for injection for each 5 batches of specimens and before the end of the test; and calculate it together with the peak area of the first

5-needle system suitability and the acetone standard peak area confirmed each time in the middle. The relative standard deviation (RSD) of the repeatability test is no more than 10.0%; and the number of theoretical plates of the acetone peak in the acetone standard use solution (A.5.2.2) shall be no less than 5000. If the above conditions are not met, the test data in between is invalid. Re-test the system suitability, and re-test after the system suitability is qualified. The system suitability is valid for 48h.

A.5.6 Analysis steps

After the system applicability 5-needle repeatability is qualified, one needle of water sample is injected; and then 2 needles of reference solution (A.5.2.4) and 2 needles of specimen solution (A.5.2.3) are injected in sequence. The prepared reference solution (A.5.2.4) and specimen solution (A.5.2.3) are equilibrated at 80°C for 60min; and 1.0 mL of headspace gas is injected into the sample. Measure under the above chromatographic conditions and record the chromatogram.

GB 1903.42 | GB 1903.45 | GB 1903.43 | GB 1903.59 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

How to Download GB 1903.44-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 1903.44-2020

$135.00