Valid

GB 1886.315-2021National food safety standard - Food additives - Dactylopius coccus Costa and its aluminum lake (English PDF)

食品安全国家标准 食品添加剂 胭脂虫红及其铝色淀

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for GB 1886.315-2021 in 30 minutes.

Issued by

NHC; SAMR

Level / Type

National · Mandatory

Issue date

February 22, 2021

Implementation date

August 22, 2021

Scope

GB 1886.315-2021 is the English-translated version of 食品安全国家标准 食品添加剂 胭脂虫红及其铝色淀.

GB 1886.315-2021 is the Chinese national food safety standard for the food additive Dactylopius coccus Costa and its aluminum lake, the colouring extracted from the dried body of the female adult insect with water, methanol and/or ethanol, concentrated and then refined by chelating with an aluminum salt.

It gives the molecular formula, structural formula and relative molecular mass of carminic acid, its marker component, and fixes the sensory and technical requirements.

Appendix A sets out the inspection methods: the solubility and colour reactions used for identification, the spectrophotometric measurement of carminic acid at 494 nm, the loss on drying by GB 5009.3-2016, the dilute ammonia insoluble matter and the headspace gas chromatography of residual solvents. It was issued on 22 February 2021 and has applied since 22 August 2021.

Found what you need?

Document preview — GB 1886.315-2021

National Standard of the People's Republic of China

Issued by: NHC; SAMR

Contents

  • 1 Scope3
  • 2 Molecular formula, structural formula, and relative molecular mass of iconic components3
  • 3 Technical requirements3
  • Appendix A Inspection method6

1 Scope

This Standard applies to the food additive Dactylopius coccus Costa aluminum lake, which is obtained from the dry body of the female adult of Dactylopius coccus Costa, as the raw material, which is extracted by water, methanol and/or ethanol solution, and then concentrated, and is further refined by chelating with aluminum salt.

2 Molecular formula, structural formula, and relative molecular mass of iconic components

2.1 Molecular formula

Carminic acid: C22H20O13

2.2 Structural formula

Carminic acid:

2.3 Relative molecular mass

Carminic acid: 492.39 (according to the international relative atomic mass in 2018)

3 Technical requirements

3.1 Sensory requirements

Appendix A Inspection method

A.1 General provisions

The reagents and water that are used in this Standard, when no other requirements are specified, refer to analytical reagents and grade-III water which is specified in GB/T 6682. The standard solution, the standard solutions, preparations and products for impurity determination, which are used in the test, are all prepared in accordance with the provisions of GB/T 601, GB/T 602, and GB/T 603, when no other requirements are specified. The solution used in the test, if not indicated which solvent is used, refers to aqueous solution.

A.2 Identification test

A.2.1 Reagents and materials

A.2.1.1 Sodium hydroxide (or potassium hydroxide) solution: 100 g/L.

A.2.1.2 Sodium dithionite (Na2S2O4).

A.2.1.3 Sulfuric acid.

A.2.1.4 Hydrochloric acid solution: 1+4.

A.2.1.5 Pentanol.

A.2.1.6 Petroleum ether

A.2.1.7 5% uranyl acetate solution.

A.2.1.8 Activated carbon: iodine adsorption value >= 400 mg/g.

A.2.2 Analysis steps
A.2.2.1 Solubility

Dactylopius coccus Costa is easily soluble in water. The Dactylopius coccus Costa aluminum lake, of which the main cationic component is ammonium ions (Dactylopius coccus Costa aluminum ammonium), is easily soluble in water at pH 3.0 and pH 8.5; of which the main cationic component is calcium ions (Dactylopius coccus Costa aluminum calcium), is insoluble in water at pH 3.0 and easy soluble in water at pH 8.5.

A.2.2.2 Color reaction

Accurately weigh 1 g of Dactylopius coccus Costa sample, accurate to 0.001 g, or 0.1 g of Dactylopius coccus Costa aluminum lake, accurate to 0.000 1 g; dissolve in 30 mL of hydrochloric acid solution and boil; cool to room temperature; then, transfer to a 1 000 mL volumetric flask; use water to fix the volume to the mark; shake well. On the spectrometer, use a 1 cm cuvette; use water to do a blank test; measure the absorbance at the maximum absorption wavelength of 494 nm. The absorbance value of the tested solution shall be between 0.650 ~ 0.750; otherwise, the sample volume needs to be adjusted separately to prepare the sample solution.

A.3.5 Result calculation

Calculate the mass fraction w1 of carminic acid according to Formula (A.1).

Where:

A - absorbance value of the sample solution;

10 - conversion coefficient;

m1 - mass of the sample, in grams (g);

139 - theoretical extinction value of the 1% carminic acid solution.

The test results are based on the arithmetic mean of the parallel determination results; three significant figures are reserved. The absolute difference between two independent determination results which are obtained under repeatability conditions shall not be greater than 1.0% of the arithmetic mean.

A.4 Loss on drying

Adopt Method I direct drying method of GB 5009.3-2016; the drying temperature and time are 135 °C ± 2 °C and 3 h respectively.

A.5 Determination of dilute ammonia insoluble matter

A.5.1 Reagents and materials
A.5.1.1 Ammonia solution

Measure 160 mL of ammonia water; use water to dilute to 500 mL.

A.5.1.2 0.1% dilute ammonia water: Measure 4 mL of nitrogen water; use water to dilute to 1 000 mL.

A.5.2 Instruments and apparatuses
A.6.1.4 Water

Grade-1 water that is specified in GB/T 6682.

A.6.2 Instruments and apparatuses

Gas chromatograph: with hydrogen flame ionization detector (FID) and headspace sampler.

A.6.3 Reference chromatographic conditions

A.6.3.1 Chromatographic column: fused silica; the column length is 30 m; the inner diameter is 0.53 mm; the coating is 100% dimethyl polysiloxane; the coating thickness is 5 µm. Or a chromatographic column of equivalent performance.

A.6.3.2 Carrier gas: helium.

A.6.3.3 Flow rate: 208 kPa, 5 mL/min.

A.6.3.4 Column temperature: maintain 35 °C for 5 minutes; then, rise to 90 °C at a rate of 5 °C/min; maintain for 6 minutes.

A.6.3.5 Temperature of the sample injector: 140 °C.

A.6.3.6 Temperature of the detector: 300 °C.

A.6.4 Reference headspace conditions

A.6.4.1 Sample heating temperature: 60 °C.

A.6.4.2 Sample heating time: 10 min.

A.6.4.3 Injector temperature: 70 °C.

A.6.4.4 Transmission temperature: 80 °C.

A.6.4.5 Sample gas injection: split mode, 1.0 mL.

A.6.5 Analysis steps
A.6.5.1 Preparation of internal standard solution

Pipette 50 mL of water into a 50 mL injection bottle; seal; accurately weigh, accurate to 0.000 1 g. Pipette 15 µL of trimethyldipentanone; inject it into the sample bottle through the membrane; mix well; weigh again, to the nearest 0.000 1 g.

A.6.5.2 Preparation of blank solution

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

How to Download GB 1886.315-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 1886.315-2021

$120.00