Scope

GB 18282.3-2009 is the English-translated version of 医疗保健产品灭菌 化学指示物 第3部分:用于BD类蒸汽渗透测试的二类指示物系统.

GB 18282.3-2009 — This Part of GB 18282 specifies the requirements for chemical indicators to be used in the steam penetration test for steam sterilizers for wrapped goods, e.g., instruments and porous materials. The indicator for this purpose is a Class 2 indicator as described in ISO 11140-1. Indicators complying with this Part of GB 18282 are intended for use in combination with the standard test pack as described in EN 285. This Part of GB 18282 does not consider the performance of the standard test pack, but does specify the performance of the indicator systems.

Found what you need?

Document preview — GB 18282.3-2009

National Standard of the People's Republic of China

ICS
发布日期
Classification
C47

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • Foreword...3
  • Introduction...4
  • 1 Scope...5
  • 2 Normative References...5
  • 3 Terms and Definitions...6
  • 4 General Requirements...6
  • 5 Indicator System Format...6
  • 6 Performance Requirements...7
  • 7 Packaging and Labelling...8
  • 8 Quality Assurance...9
  • Annex A (Normative) Determination of Strength after Steam Sterilization...10

Foreword

All the technical contents in this Part are mandatory.

GB 18282 Sterilization of Health Care Products – Chemical Indicators consists of the following

parts:

--- Part 1: General;

--- Part 3: Class 2 Indicator Systems for Use in the Bowie and Dick-Type Steam Penetration

Test;

--- Part 4: Class 2 Indicators as an Alternative to the Bowie and Dick-Type Test for Detection

of Steam Penetration;

--- Part 5: Class 2 Indicators for Bowie and Dick-Type Air Removal Tests.

This Part is Part 3 of GB 18282.

This Part equivalently adopts ISO 11140-3:2007 Sterilization of Health Care Products –

Chemical Indicators – Part 3: Class 2 Indicator Systems for Use in the Bowie and Dick-Type

Steam Penetration Test.

Compared with ISO 11140-3:2007, the major differences with this Part are as follows:

--- Make the editorial modifications as per the requirements in GB/T 1.1;

--- Delete the Foreword of the international standard;

--- For other international standards cited in this Part, if they have been converted into

Chinese standards, this Part will replace the referenced international standard number

with the corresponding national standard number, and indicate the adoption relationship.

The Annexes A ~ K of this Part are normative.

This Part was proposed by State Food and Drug Administration.

This Part shall be under the jurisdiction of National Technical Committee on Disinfection

Technology and Equipment of Standardization Administration of China (SAC/TC 200).

Drafting organizations of this Part: Guangzhou Medical Device Quality Supervision and

Inspection Center of State Food and Drug Administration; Beijing Medicare Jincheng Medical

Devices Co., Ltd.; and Shinva Medical Instrument Co., Ltd.

Chief drafters of this Part: Lu Wenjuan, Lu Zhong, Yuan Qin, Hu Xianghua, Lv Liansheng, and

Wan Jiuru.

Sterilization of Health Care Products – Chemical Indicators

– Part 3: Class 2 Indicator Systems for Use in the Bowie and

Dick-Type Steam Penetration Test

1 Scope

This Part of GB 18282 specifies the requirements for chemical indicators to be used in the

steam penetration test for steam sterilizers for wrapped goods, e.g., instruments and porous

materials. The indicator for this purpose is a Class 2 indicator as described in ISO 11140-1.

Indicators complying with this Part of GB 18282 are intended for use in combination with the

standard test pack as described in EN 285. This Part of GB 18282 does not consider the

performance of the standard test pack, but does specify the performance of the indicator systems.

2 Normative References

The provisions in following documents become the provisions of this Part through reference in

this Part of GB 18282. For dated references, the subsequent amendments (excluding

corrigendum) or revisions do not apply to this Standard, however, parties who reach an

agreement based on this Standard are encouraged to study if the latest versions of these

documents are applicable. For undated references, the latest edition of the referenced document

applies.

GB/T 11501 Photography - Density Measurement - Part 3: Spectral Conditions (GB/T

11501-2008, ISO 5-3:1995, IDT)

GB/T 12823.1 Photography - Density Measurement - Part 1: Terms, Symbols and

Notations (GB/T 12823.1-2008, ISO 5-1:1984, IDT)

GB/T 12823.4-2008 Photography – Density Measurement - Part 4: Geometric Conditions

for Reflection Density (ISO 5-4:1995, IDT)

ISO 187:1990 Paper, Board and Pulps -- Standard Atmosphere for Conditioning and

Testing and Procedure for Monitoring the Atmosphere and Conditioning of Samples

ISO 2248 Packaging - Complete, Filled Transport Packages - Vertical Impact Test by

Dropping

manufacturer.

Compliance shall be tested in accordance with Annex B.

f) It shall permit writing in permanent ink to be made legibly on both processed and

unprocessed materials. Markings made before processing shall be legible after

processing.

g) It shall be of size A4 in accordance with ISO 5457.

6 Performance Requirements

6.1 The indicator shall meet the following requirements.

a) It shall show a uniform color change complying with 5 e) after exposure to dry saturated

steam at 134 (+1.5 0 )°C for 3.5 min ± 5 s or after exposure to dry saturated steam at 121

(+1.5 0 )°C for 15 min ± 5 s or both.

Compliance shall be tested in accordance with Annex C.

b) When placed in the center of a standard test pack, it shall show a non-uniform color

change when the temperature at the center of the standard test pack is 2°C lower than the

temperature of the chamber drain of the steam exposure apparatus (see Annex H).

Compliance shall be tested in accordance with Annex I.

c) It shall show no discernible color change after exposure to dry heat at (140 ± 2)°C for not

less than 30 min.

Compliance shall be demonstrated in accordance with Annex D.

With some indicators a slight color change can occur. This shall be acceptable if the

change that occurs is markedly different from that brought about by exposure to steam

in accordance with 6.1 a) and within the limits specified by the manufacturer.

d) It shall not visibly transfer indicator reagent to the material of the test load in intimate

contact with the indicator during processing.

Compliance shall be demonstrated in accordance with Annex F.

6.2 The indicator shall comply with the requirements of this part of GB 18282 for the duration

of the shelf life specified by the manufacturer.

If any change in the indicator occurs during ageing, it shall be different to the change on

exposure to dry saturated steam [as described in 6.1 a)], and shall have either inactivated the

indicator so that no further change can take place or not affected the performance of the

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB 18282 · GB/T 11501 · ISO 5 · GB/T 12823.1 · GB/T 12823.1-2008 · GB/T 12823.4-2008 · ISO 187 · ISO 2248 · ISO 5457

How to Download GB 18282.3-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 18282.3-2009

$340.00