GB 18281.5-2015Sterilization of health care products -- Biological indicator -- Part 5: Biological indicators for low-temperature steam and formaldehyde sterilization processes (English PDF)
医疗保健产品灭菌 生物指示物
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for GB 18281.5-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Mandatory
Issue date
December 10, 2015
Implementation date
January 1, 2017
Scope
GB 18281.5-2015 is the English-translated version of 医疗保健产品灭菌 生物指示物.
GB 18281.5-2015 is the Chinese standard "Sterilization of health care products -- Biological indicator -- Part 5: Biological indicators for low-temperature steam and formaldehyde sterilization processes".
Its scope clause reads: GB 18281 of the provisions of this part of the test microorganisms, bacterial suspension, the carrier contamination, biological indicator and low temperature steam formaldehyde sterilization General requirements for sterilization agent to assess the treatment effect of biological indicator test method.
Note 1.The requirements for low temperature steam formaldehyde sterilization process control and confirmation, see ISO 14937. Note 2.For the safety requirements in the workplace, see national or regional regulations.
Its clauses include terms and definitions; general requirements; test bacteria; bacterial suspension; carrier and the inner packaging; carrier contamination and biological indicators; the number and resistance of microorganisms.
Found what you need?
Document preview — GB 18281.5-2015
National Standard of the People's Republic of China
- ICS
- 11.080.01
- Classification
- C 47
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 1 General requirements
- 5 test bacteria
- 6 1 bacterial suspension
- 7 carrier and the inner packaging
- 8 carrier contamination and biological indicators
- 9 Number of microbial resistance and
- Annex B (informative) low temperature steam formaldehyde principle with liquid biological indicators Test Method
1 Scope
GB 18281 of the provisions of this part of the test microorganisms, bacterial suspension, the carrier contamination, biological indicator and low temperature steam formaldehyde sterilization
General requirements for sterilization agent to assess the treatment effect of biological indicator test method.
Note 1.The requirements for low temperature steam formaldehyde sterilization process control and confirmation, see ISO 14937.
Note 2.For the safety requirements in the workplace, see national or regional regulations.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO 11138-1.2006 Sterilization of health care products - Biological indicators - Part 1.General (Sterilizationofhealthcare products-Biologicalindicators-Part 1.Genralrequirements)
3 Terms and Definitions
As defined in ISO 11138-1 and the following terms and definitions apply to this document.
3.1 Low temperature steam formaldehyde sterilization
By the power exhaust, so that pre-packaged goods in the vacuum state is exposed to steam at temperatures below 100 °C, the injection of formaldehyde gas,
Such sterilizing agents in the maintenance time remains steady process.
4 General requirements
ISO 11138-1 requirements apply to this section.
5 test bacteria
5.1
Test bacteria should be Bacillus stearothermophilus or other has been found to comply with the requirements of this strain of microorganism equivalent performance.
Note 1.Bacillus stearothermophilus have been reclassified to Bacillus stearothermophilus.
Note 2.The currently considered applicable to Bacillus stearothermophilus, as NCIB8224, DSM6790, ATCC10149 and ATCC12980.
5.2
If the use of a test bacteria Bacillus stearothermophilus ground outside, then this strain of bacteria resistance test suitability should be determined.
6 bacterial suspension
ISO 11138-1 requirements apply to this section.
7 carrier and the inner packaging
7.1
low temperature steam formaldehyde sterilization agent biological indicator carriers and inner packing material should conform to ISO 11138-1.2006 5.2
And ISO 11138-1.2006 requirements in Appendix B of.
Note. Due to the cellulose surface chemical formaldehyde adsorption filter paper type is not suitable as a carrier.
7.2
should comply with the determined exposure conditions.
a) Minimum temperature exposure. not less than 5 °C (above the manufacturer claims the highest temperature);
b) maximum exposure temperature. According to the manufacturer's maximum claims; If the manufacturer is not declared, should not be less than the maximum exposure temperature
100 °C;
c) Exposure time. not less than 60min.
Note. These conditions have become a caution, with practical limits on bacteria in the range of application of low temperature steam formaldehyde sterilization process. Selection criteria to be able to significantly
It shows the actual low temperature steam formaldehyde sterilization process to the actual requirements of the carrier.
8 carrier contamination and biological indicators
ISO 11138-1 requirements apply to this section.
9 The number and resistance of microorganisms
9.1
Manufacturers should be based on ISO 11138-1.2006 6.4 Characteristics of predetermined resistance requirements.
9.2
Proliferation amount viable count should be less than 0.1 × 10n/per unit (eg. bacteria per ml suspension, each to be inoculated with bacteria, each student
Adhesive tape cells).
With cell proliferation and the amount of biological cells with 9.3 to be vaccinated should be not less than 1.0 × 105.
9.4
resistance should be expressed as D value at 60 °C, and in minutes (min). Each batch/lot of contamination or biological indicator carriers D
D values apply at 60 °C that is kept to one decimal place.
9.5
when tested in accordance with Appendix A, the medium carrier contamination or biological indicator comprises D60 value to stearothermophilus Bacillus
Should >=6min. Other micro-organisms should also be applied to the D value.
Resistance 9.6 biological indicator can also be used FBIO value indicates (see ISO 11138-1.2006 3.7). This section GB 18281 and its
The specific part of his resistance shall be tested in accordance with specific conditions standards.
9.7
shall be according to ISO 11138-1.2006 Determination of D value of Appendices C and D of the given method.
9.8
D value determination and survival - kill response characteristics based on the process parameters in Appendix A.
9.9
Survival - killing range available ISO 11138-1.2006 Appendix E formula to calculate.
NOTE. To compare different batches of the same manufacturer's product information for the user is useful.
Example. Apply ISO 11138-1.2006 Appendix E of the formula and the population and minimum D values given in this section, survival - kill reaction characteristic values are.
--- 60 °C when. survival time >=18min, kill time <=54min.
Appendix A (Normative)
Determination of low temperature steam formaldehyde sterilization process resistance method
A.1 General
This method is based on a carrier immersed in formalin contamination qualitative testing. The results of this test method than the use of gas cavity
The results of the method have better reproducibility.
A.3 provides the special requirements of the test method.
A.2 Ranjun carrier exposure conditions
A.2.1 test system comprising an aqueous solution of formaldehyde containing 10mL test tube, and the tube placed in a water bath of automatic temperature control. Measurement
Test systems should be able to (accurate to ± 10s) period of time to maintain a specific exposure conditions in 1min ~ 150min.
Chemical analysis methods to determine the concentration of the aqueous formaldehyde solution A.2.2.
A.2.3 the method should be validated.
A.3 Method
A.3.1 The carrier contamination completely immersed in the test tube has been preheated to 60 °C ± 0.5 °C of 1mol/L ± 0.01mol/L of aqueous formaldehyde
Solution.
A.3.2 confirm Ranjun carrier is completely immersed in formalin instead of floating on the surface.
A.3.3 The protection technology to prevent accidental contamination during testing.
A.3.4 at the end of the set exposure time, remove the formaldehyde solution in the carrier contamination.
A.3.5 remove excess liquid carrier, which will be equipped with immersion filtered 2% Na2SO3 solution tubes 10min at room temperature,
The reaction on the carrier out of the residual formaldehyde. Cover tube. Try not to pay attention to stir formaldehyde solution and neutralizer in order to prevent "washed away" micro test biological.
NOTE. histidine and cysteine are effective neutralizers.
A.3.6 specific growth media should guarantee coverage test microorganisms.
NOTE. This test applies soybean casein digestive enzymes.
A.3.7 The carrier was transferred to a growth medium containing 10mL (A.3.6) tube. Cover tube.
A.3.8 The tubes were kept 90 °C 60min to stimulate spore activity.
A.3.9 Finally, the culture carrier (see ISO 11138-1.2006 in Chapter 7).
A.4 Determination of resistance
Resistance characteristic values are applied ISO 11138-1.2006 Annex C, D and Appendix E for a given method for determining the Appendix.
Appendix B (Informative)
Low temperature steam formaldehyde Biological indicators for liquid test method principle
B.1 General
To indicate Test method reproducibility, use of specific test equipment (resistance tester) and test methods. In the low-temperature steam
Formaldehyde sterilization process, the resistance tester formaldehyde gas concentration is extremely difficult to achieve a stable, because when a certain amount of formaldehyde injected into the container, will
A small amount of water droplets (condensate) dissolved formaldehyde appears. It was dissolved in water in accordance with the concentration of different temperatures, higher than in the gaseous
State concentration of 1000-fold to 10,000-fold.
Therefore, this part of the formaldehyde concentration can clear liquid test methods in order to achieve reproducible test methods.
B.2 low temperature steam formaldehyde sterilization processes
Even under continuous steam conditions and a stable concentration of formaldehyde gas sterilization process is still heavily dependent on the design of the sterilization chamber and the negative
Load characteristics thereof. Formaldehyde sterilization process can be simply divided into two steps.
a) in the steam sterilization process, the load surface will produce droplets condensate film, the condensation process is very fast;
b) because the formaldehyde concentration changes in the gas-liquid equilibrium state of great (1.1000 ~ 1.10 000), the time to reach the required balance
Relatively long, in practice, the time required for 10min ~ 2h.
The sterilization process depends on the concentration of formaldehyde in the liquid state, for example, the surface of the condensate. Confirm this equilibrium conditions constant term non-time
Often difficult.
references
[1] ISO 14161.2000 Sterilizationofhenlthcareproducts-Biologicalindicators-Guidancefor theselection, useandinterpretationofresults
[2] ISO 14937.2000 Sterilizationofhenlthcareproducts-Generalrequirementsforcharacter- izationofasterilizingagentandthedevelopmentvalidatinecontrolofsterilizationprocessfor medicaldevices
[3] EN14180.2003 Sterilizersformedicalpurposes-Lowtemperaturesteamandformalde- hydesterilizers-Requirementsandtesting
GB/T 18281.2-2024 | GB/T 18281.3-2024 | GB/T 18281.4-2024 | GB/T 18281.7-2024 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 11138
How to Download GB 18281.5-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 18281.5-2015
$75.00