Valid

GB 10408.3-2000Detectors for intruder alarm systems. Part 3: Microwave doppler detectors for use in building (English PDF)

Preview PDF

Also coversGB10408.3-2000

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for GB 10408.3-2000 in 30 minutes.

Issued by

China State Bureau of Quality and Technical Supervision

Level / Type

National · Mandatory

Issue date

October 17, 2000

Implementation date

June 1, 2001

Scope

GB 10408.3-2000 (Detectors for intruder alarm systems. Part 3: Microwave doppler detectors for use in building) is available as an English-translated PDF.

GB 10408.3-2000 is the Chinese standard "Detectors for intruder alarm systems. Part 3: Microwave doppler detectors for use in building". Its scope clause reads: This Standard gives the specific requirements and test procedures for microwave Doppler detectors for use in intruder alarm systems installed in buildings.

This Standard is an addition to the general requirements for detectors for use in intruder alarm systems as specified in GB 10408.1 Detectors for intruder alarm systems - Part 1.

Requirements for detectors - General, and it shall also be used in conjunction with the standard for General requirements for alarm system, IEC Publication 839-1-1.

The object of this Standard is to specify those requirements for microwave Doppler detectors which will ensure that they will perform satisfactorily and minimize false alarms.

Found what you need?

Document preview — GB 10408.3-2000

National Standard of the People's Republic of China

ICS
13.310
Classification
A 91

Issued by: China State Bureau of Quality and Technical Supervision

Contents

  • Foreword3
  • IEC Foreword4
  • 1 Scope5
  • 2 Normative references5
  • 3 Definitions6
  • 4 General considerations6
  • 5 Technical requirements7
  • 6 Test procedures9

1 Scope

This Standard gives the specific requirements and test procedures for microwave Doppler detectors for use in intruder alarm systems installed in buildings.

This Standard is an addition to the general requirements for detectors for use in intruder alarm systems as specified in GB 10408.1 Detectors for intruder alarm systems - Part 1. Requirements for detectors - General, and it shall also be used in conjunction with the standard for General requirements for alarm system, IEC Publication 839-1-1.

The object of this Standard is to specify those requirements for microwave

Doppler detectors which will ensure that they will perform satisfactorily and minimize false alarms.

2 Normative references

The following standards contain the provisions which, through reference in this

Standard, constitute the provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below.

GB 10408.1-2000 Detectors for intruder alarm systems - Part 1.

Requirements for detectors - General [idt IEC 839-2-2.1987]

IEC 68-1.1988 Environmental testing - Part 1. General and guidance

IEC 839-1-1.1988 Alarm systems - Part 1. General requirements, Section

One - General

IEC 839-1-3.1988 Section Three - Environmental testing

The tests may be carried out at any range within the range adjustment of the detector. The range control shall not be altered during the environmental tests.

The reference target shall move towards the detector from directly in front of the detector beyond the adjusted range at a speed of approximately 1 m/s. The distance from the detector when an alarm condition occurs shall be measure and recorded.

The distance from the detector where an alarm condition occurs after each environmental test shall not vary by more than 10% of the initial distance.

The tests may be simulated provided that it can be shown that the simulation gives the same results as the test procedure described.

For the following tests the detector shall be set for maximum stated range.

- electrical spikes;

- electrostatic discharge;

- electromagnetic fields.

GB 16796-2022 | GB 15210-2018 | GB 8108-2014 | GB 10408-2025 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

Normative references

GB 10408.1-2000 · IEC 839 · IEC 68

How to Download GB 10408.3-2000

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 10408.3-2000