Valid

GA/T 536.2-2005Grading and test method on fire hazard for flammable and explosive hazmats -- Part 2: Test method of grading for flammable solids (English PDF)

易燃易爆危险品 火灾危险性分级及试验方法 第2部分:易燃固体分级试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (3 pages)

Need quotation for your management?

Get a formal quotation for GA/T 536.2-2005 in 30 minutes.

Issued by

Ministry of Public Security of the People Republic of China

Level / Type

National · Recommended

Issue date

March 17, 2005

Implementation date

October 1, 2005

Scope

GA/T 536.2-2005 is the English-translated version of 易燃易爆危险品 火灾危险性分级及试验方法 第2部分:易燃固体分级试验方法.

GA/T 536.2-2005 — This part of GA/T 536 specifies the classification test method for flammable solids. This section applies to flammable solids that require a fire hazard classification.

This section does not apply to self-reactive substances and solid desensitized explosives.

Found what you need?

Document preview — GA/T 536.2-2005

National Standard of the People's Republic of China

ICS
13.220.01
Classification
C 80

Issued by: Ministry of Public Security of the People Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Instruments and apparatus
  • 3 Test conditions
  • 4 Test steps
  • 4.1 Preliminary screening test
  • 4.2 Burning rate test

Foreword

GA/T 536 "Classification and Test Methods for Fire Hazard of Flammable and Explosive Dangerous Goods" is divided into 6 parts.

--- Part 1. Classification of fire hazards for inflammable and explosive dangerous goods;

---Part 2. Test method for flammable solids classification;

---Part 3. Test methods for the classification of substances that are susceptible to spontaneous combustion;

---Part 4. Test method for grading of flammable substances in contact with water;

---Part 5. Method for the classification of solid oxidizing substances;

--- Part 6. Method for the classification of liquid oxidizing substances.

This part is the second part of GA/T 536.

This section mainly refers to the United Nations Committee of Experts on the Transport of Dangerous Goods, Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria.

(Revised 3) The technical content of Part III 33.2.1 is formulated, and its structure and writing rules are in accordance with GB/T 1.1-2000.

Provisions.

This part was proposed by the Fire Department of the Ministry of Public Security of the People's Republic this part is under the jurisdiction of the First Technical Committee of the National Fire Protection Standardization Technical Committee (SAC/TC113/SC1).

This section is responsible for drafting the unit. Tianjin Fire Research Institute of the Ministry of Public Security.

Participated in the drafting of this section. Hebei Provincial Public Security Department Fire Bureau.

1 Scope

This part of GA/T 536 specifies the classification test method for flammable solids.

This section applies to flammable solids that require a fire hazard classification.

This section does not apply to self-reactive substances and solid desensitized explosives.

2 Instruments and apparatus

a) Make molds and accessories for stacking test samples, see Figure 1;

b) ignition source, the fuel is usually butane, and gas or natural gas can also be used;

c) Inorganic insulation board (impermeable, thermal conductivity at 0 ° C is not higher than 0.23W/m · K);

d) stopwatch (minimum division is not more than 0.1s);

e) ruler (minimum division is not more than 1mm);

f) Dropper.

3 Test conditions

The temperature is (20 ± 5) ° C and the humidity is (50 ± 10) % RH.

4 Test steps

4.1 Preliminary screening test

4.1.1 Loosely load the test sample in the form of granules, powder or paste into the mold and free the mold from a height of 20 mm from the hard surface.

Next, after three times of piercing, the mold is turned over, and the test sample is buckled on the inorganic heat insulation board to make a 250 mm wide, 20 mm wide, and 10 mm high cross section.

It is a stack of triangles.

4.1.2 Burn the end of the test sample with the flame of the ignition source (flame diameter 5mm ~ 8mm) until it ignites.

a) If the test sample stack is not ignited within 2 min (metal or metal alloy powder for 20 min) test time, or after ignition If the flame spreads along the stack < 200mm, the substance is not a flammable solid;

b) If the test sample stack is ignited within 2 min (metal or metal alloy powder in 20 min) test time, and the flame along If the stacking distance is >=200mm, the following burning rate test should be continued.

4.2 Burning rate test

4.2.1 Reprocess a stack of test specimens through the preliminary screening test on the inorganic insulation board (method same as 4.1.1).

4.2.2 Make a groove of 3m deep and 5mm in diameter on the ridge at 210mm~220mm, and add 1mL of humectant dropwise.

Make sure that the cross section of the stack is completely wet (this part of the test does not apply to metal or metal alloy powders).

Note. Wetting agents do not contain flammable solvents, and active substances in humectants should not exceed 1%.

4.2.3 ignite one end of the stack with the above flame, and measure the flame to spread 100mm after the flame spreads along the stack to 80mm.

The time required and record the time the flame passes through the wet section.

4.2.4 For metal or metal alloy powders, record the time that the flame spreads to the full length of the stack after ignition.

4.2.5 Repeat the test five times and take the average of the six tests as the burning rate of the test sample.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 3 pages — is available in the English PDF.

How to Download GA/T 536.2-2005

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
3 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GA/T 536.2-2005

$40.00