Valid

GA/T 1711-2020Controlling limits and measurement methods for electromagnetic environment in surveillance center of security systems (English PDF)

Preview PDF

Also coversGAT1711-2020

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for GA/T 1711-2020 in 30 minutes.

Issued by

Ministry of Public Security of the People's Republic of China

Level / Type

National · Recommended

Issue date

February 11, 2020

Implementation date

August 1, 2020

Scope

GA/T 1711-2020 (Controlling limits and measurement methods for electromagnetic environment in surveillance center of security systems) is available as an English-translated PDF.

GA/T 1711-2020 is the Chinese standard "Controlling limits and measurement methods for electromagnetic environment in surveillance center of security systems". Its scope clause reads: This Standard specifies controlling limits and measurement methods for electromagnetic environment in surveillance center of security systems.

This Standard is applicable to electromagnetic environment evaluation for surveillance center of security systems. The electromagnetic environment evaluation in areas such as security inspection and radio frequency reading in the security protection system may refer to this Standard to implement.

Its clauses include terms and definitions; measurement method; measurement time and data processing; measurement record or report. It was issued by the Ministry of Public Security of the People's Republic of China on 2020-02-11 and took effect on 2020-08-01.

Found what you need?

Document preview — GA/T 1711-2020

National Standard of the People's Republic of China

ICS
13.020
Classification
A 91

Issued by: Ministry of Public Security of the People's Republic of China

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative references...4
  • 3 Terms and definitions...4
  • 4 Controlling limits...5
  • 5 Measurement method...6
  • 5.1 Requirements for measuring instruments...6
  • 5.2 Measuring position...6
  • 5.3 Measurement equipment layout...7
  • 5.4 Measurement frequency band and physical quantity...8
  • 6 Measurement time and data processing...8
  • 7 Measurement record or report...8

1 Scope

This Standard specifies controlling limits and measurement methods for electromagnetic environment in surveillance center of security systems.

This Standard is applicable to electromagnetic environment evaluation for surveillance center of security systems. The electromagnetic environment evaluation in areas such as security inspection and radio frequency reading in the security protection system may refer to this Standard to implement.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB 8702-2014, Controlling limits for electromagnetic environment

GB 50348-2018, Technical code for engineering of security and protection system

HJ 972, Monitoring method for electromagnetic radiation environment

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in GB

8702-2014, GB 50348-2018 as well as the followings apply.

3.1 surveillance center of security system the central control room that receives and processes security system information, handles alarm events, and manages control system equipment; it is usually divided into guard area and equipment area

5 Measurement method

5.1 Requirements for measuring instruments

5.1.1 Electric field and magnetic field measuring equipment below 100kHz meet

the following requirements:

a) 8Hz~100kHz electric and magnetic field measuring instruments shall be used. Discrete probes can be used for electric and magnetic field measuring instruments. It can also be a combination of the two;

b) Three-dimensional probe shall be used;

c) When the probe is connected to the host (handheld) through an optical fiber, the fiber length shall not be less than 2.5m;

d) Measuring instruments shall be battery powered. Continuous working time shall not be less than 12h;

e) The probe holder shall be made of non-conductive material;

f) The measuring range of electric field strength of the electric field probe shall cover at least 3V/m~100kV/m. The measuring range of magnetic induction intensity of the magnetic field probe shall cover at least

30nT~1mT;

g) The area of the magnetic field probe shall be less than 0.01m2;

h) There shall be automatic data storage function. Storage interval shall not be greater than 15s.

5.1.2 Electric and magnetic field measuring instruments above 100kHz shall meet the requirements of HJ 972.

5.1.3 When a non-selective frequency tester is used for measurement and the measurement result is higher than the limit in Table 1, it needs to use frequency selective tester for final measurement.

5.2 Measuring position

5.2.1 Guard area of surveillance center of security system
5.2.1.1 Staff position on duty

Measure the positions of the guards in the surveillance center of security system. When the working posture is sitting, the height of the measuring point from the ground is 1.2m, 1m and 0.8m respectively. When the posture is

5.4 Measurement frequency band and physical quantity

The principles for selection of measurement frequency band and physical quantity are as follows:

a) Determine the measurement frequency band and physical quantity according to the frequency range of the electromagnetic field in the measurement environment;

b) When the frequency is less than 30MHz, the electric field intensity and magnetic induction intensity shall be measured;

c) When the frequency is not less than 30MHz, only the electric field strength or magnetic field strength, or equivalent plane wave power density can be measured.

6 Measurement time and data processing

The measurement shall be performed during the normal working hours of the equipment of surveillance center of security system. Each height of each measuring point is measured 5 times respectively. Each measurement time shall not be less than 15s. Take the steady state value. Record the maximum value of 5 times as the measurement result.

If the measurement result at a certain position exceeds 30% of the environmental limit in Table 1, the physical quantity shall be measured for not less than 24h (the battery replacement time is not included) at the measurement position. It shall be recorded at least every 15s. Respectively count the maximum, minimum, 95% and 50% time probability of not exceeding the field strength values E95 and E50. Draw the distribution diagram of electric field or magnetic field and time as needed. List the maximum, minimum, E95 and E50.

Use E95 as the basis for evaluation.

NOTE: If measure once every 15s and continuously measure for 24h, a total of 5760 measurement data will be generated. When processing, sort all data from largest to smallest. Take the first data as the maximum value. Take the 289th data as E95. Take the

2880th data as E50. Take the 5760th data as the minimum value.

7 Measurement record or report

The measurement record and report for electromagnetic environment of the surveillance center of security system shall include at least the following:

- Environmental conditions such as temperature and relative humidity during

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

How to Download GA/T 1711-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GA/T 1711-2020

$145.00