DL/T 506-2018Method of humidity measurement of sulfur hexafluoride insulated gas in electrical equipment (English PDF)
六氟化硫电气设备中绝缘气体湿度测量方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for DL/T 506-2018 in 30 minutes.
Issued by
National Energy Administration
Level / Type
National · Recommended
Issue date
June 6, 2018
Implementation date
October 1, 2018
Scope
DL/T 506-2018 is the English-translated version of 六氟化硫电气设备中绝缘气体湿度测量方法.
DL/T 506-2018 is the Chinese standard "Method of humidity measurement of sulfur hexafluoride insulated gas in electrical equipment". Its scope clause reads: This Standard specifies the method for measuring the humidity of insulated gas in sulfur hexafluoride electrical equipment.
This Standard is applicable to the measurement of the humidity of the insulated gas in sulfur hexafluoride electrical equipment in the type test, exit-factory test, handover test and preventive test.
The mixed gas insulated electrical equipment can be implemented as a reference. Its clauses include terms and definitions; requirements for humidity meter; requirements for the measurement gas circuit; requirements for measuring ambient temperature; temperature conversion of measurement results; safety precautions; report on measurement results.
It was issued by the National Energy Administration on 2018-06-06 and took effect on 2018-10-01.
Found what you need?
Document preview — DL/T 506-2018
National Standard of the People's Republic of China
- ICS
- 29.240
- Classification
- F 20
Issued by: National Energy Administration
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative References...5
- 3 Terms and Definitions...5
- 4 Requirements for Humidity Meter...7
- 5 Requirements for the Measurement Gas Circuit System...8
- 6 Requirements for Measuring Ambient Temperature and Humidity...8
- 7 Requirements for Measuring Pressure...9
- 8 Expression of Humidity...9
- 9 Measurement Method...9
- 10 Temperature Conversion of Measurement Results...11
- 11 Safety Precautions...11
- 12 Report on Measurement Results...11
- Appendix A (Informative) Conversion Formula of Humidity Measurement...13
- Appendix B (Normative) Saturated Water Vapor Pressure Table...15
1 Scope
This Standard specifies the method for measuring the humidity of insulated gas in sulfur hexafluoride electrical equipment.
This Standard is applicable to the measurement of the humidity of the insulated gas in sulfur hexafluoride electrical equipment in the type test, exit-factory test, handover test and preventive test. The mixed gas insulated electrical equipment can be implemented as a reference.
2 Normative References
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this document.
DL/T 639 Safety and Protection Rules for Operation, Test and Maintenance
Personnel of SF6 in Electrical Apparatus
3 Terms and Definitions
For the purposes of this Document, the following terms and definitions apply.
3.1 Water vapour
It is also called water vapor. The gaseous state of water, which is formed by the vaporization of water or the sublimation of ice.
3.2 Humidity
The content of water vapor in the gas.
3.3 Dry gas
Gas that contains no water vapor.
The percentage of the molar fraction of water vapor in wet gas to the molar fraction of saturated water vapor at the same temperature and pressure; or the ratio of the partial pressure of water vapor in wet gas to the saturated water vapor pressure at the same temperature.
3.14 Uncertainty of measurement
It characterizes the evaluation of the range of the measured true value.
3.15 Humidity meter
The general term for instruments that measure the humidity of a gas.
3.16 Error of indication of a measuring instrument
The indication value of the measuring instrument minus the true value of the corresponding input quantity.
3.17 Fiducial error of a measuring instrument
The percentage of indication error of the measuring instrument and the instrument range.
4 Requirements for Humidity Meter
4.1 The used humidity meter shall meet the following requirements when the ambient humidity is 10°C~40°C:
--- The measuring range of the electrolytic humidity meter shall satisfy
1µL/L~1000µL/L.
--- Fiducial error: within the range of 1µL/L~30µL/L, it shall not exceed ±10%;
within the range of 30µL/L~1000µL/L, it shall not exceed ±5%.
4.2 The measuring dew-point range of the chilled dew-point meter shall satisfy 0°C~ -
70°C when the ambient temperature is 20°C; and the measurement error shall not exceed ±0.6°C.
4.3 The dew-point range of resistance capacitive humidity measurement shall satisfy
0°C~-60°C; and the measurement error shall not exceed ±2.0°C.
4.4 The humidity meter shall be checked and calibrated regularly; and the validity period of the calibration result certificate is one year.
5 Requirements for the Measurement Gas Circuit
System
5.1 The measuring pipeline must be made of stainless steel, copper or polytetrafluoroethylene, with a wall thickness of no less than 1mm and an inner diameter of 2mm~4mm. The inner wall of the pipeline shall be smooth and clean; and it is not allowed to use pipelines with strong water absorption capacity, such as rubber pipes and polyvinyl chloride pipes, etc.
5.2 The joints are required to be well sealed, clean, and free from damage and burrs.
It is made of stainless steel or brass, and it is forbidden to use iron joints.
5.3 Use red copper gaskets or polytetrafluoroethylene gaskets for the inner pads. The
joints shall be clean; and contaminants such as flux and grease shall be removed.
5.4 The cleaning method of the pipeline shall meet the following requirements:
a) Cleaning of stainless-steel pipes. Unused or heavily contaminated stainless-steel pipes must be cleaned before use. When cleaning, rinse by 5% hot trisodium phosphate, then rinse by distilled water to neutral; finally, rinse with absolute ethanol; and then dry by high-purity nitrogen and seal both ends of the pipe for later-use.
b) Cleaning of polytetrafluoroethylene pipe. The unused polytetrafluoroethylene pipe is generally rinsed by distilled water first; then rinsed by absolute ethanol once; finally, dried by high-purity nitrogen; and sealed at both ends for later-use.
5.5 Before connecting the measuring pipeline and joints to the equipment, make sure
that the equipment joints are clean and dry, and then connect to the instrument.
5.6 The gas outlet of the measuring instrument shall be equipped with an exhaust pipe of more than 5m to prevent moisture in the atmosphere from affecting the measurement results.
6 Requirements for Measuring Ambient Temperature
and Humidity
6.1 The ambient temperature shall be between 10°C ~ 40°C (measure between 10°C and 30°C as much as possible).
6.2 The relative humidity shall be no greater than 85%.
9.2.5 Disassemble the connection between the measuring gas circuit and the sampling
joint of the equipment. Close the sampling valve on the equipment; disassemble the sampling joint on the connected equipment; cover (connect) the sealing cover (plate) of the equipment sampling joint; and restore the sealing of the equipment sampling joint.
9.2.6 Leak detection at the sampling port of the equipment. After restoring the sealing of the sampling port of the equipment, check by a sulfur hexafluoride leak detector to ensure that the sealing of the sampling port of the equipment does not leak.
9.2.7 After using the instrument, dry and blow by nitrogen for 15min ~ 20min, then turn off the instrument; and seal the inlet and outlet of the instrument for later-use.
9.2.8 The method of using the instrument refers to the instruction manual of the instrument.
10 Temperature Conversion of Measurement Results
10.1 Since the ambient temperature has a significant effect on the gas humidity in the equipment, the measurement results shall be converted to the value at 20°C in accordance with Appendix C.
10.2 If the equipment manufacturer provides conversion curves and charts, the curves
and charts provided by the manufacturer can be used for temperature conversion.
11 Safety Precautions
11.1 Safety precautions shall be taken when testing the equipment while it is live.
11.2 During the test, the test site shall be ventilated.
11.3 The safety protection of test personnel shall be implemented in accordance with the relevant provisions of DL/T 639.
12 Report on Measurement Results
The report on measurement results shall include the following:
a) The name, model, exit-factory number, and exit-factory date of the tested equipment;
b) The name, model, exit-factory number, calibration date of humidity meter;
Appendix A (Informative)
Conversion Formula of Humidity Measurement
A.1 When measuring the humidity in the gas, it can be expressed in various measurement units. Such as dew point, saturated water vapor pressure, volume ratio, weight ratio, absolute humidity, relative humidity. The measured dew point can be used to convert between measurement units.
The symbols and meanings are as follows:
ed – saturated water vapor pressure under measuring dew point, in Pa;
NOTE: When the dew-point is lower than 0°C, if the condensate on the surface of the dew sensor is supercooled water, take the saturated water vapor pressure on the surface of the supercooled water; if the condensate on the surface of the dew sensor is ice crystals, take the saturated water vapor pressure on the ice surface.
Pt – total pressure of the measurement system, in Pa;
Vr – volume ratio, in µL/L;
Wr – weight ratio, in µg/g;
Mw – relative molecular mass of the water vapour;
Mt – relative molecular mass of the test gas;
es – saturated water vapor pressure of the water under the measuring temperature, in
Pa;
U – relative humidity, in %;
Ta – temperature of gas sample, in K;
dv – absolute humidity, in g/L;
SVP0 – saturated water vapor pressure under the measuring pressure, in Pa;
SVPa – saturated water vapor pressure under the atmospheric pressure, in Pa;
P0 – absolute working pressure in the equipment, in Pa;
Pa – atmospheric pressure, in Pa.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
How to Download DL/T 506-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 639-2016 — Safety and protection guide for operation test and maintenance personnel of SF6 electrical equipment
DL/T 1010.3-2025 — High voltage static reactive power compensation devices - Part 3: Control and protection system
DL/T 1078-2025 — Test specification for operating performance of surface condenser
Secure payment via Stripe
Payments accepted
DL/T 506-2018
$355.00