CJ/T 347-2010Household combustible gas alarms and sensor (English PDF)
家用燃气报警器及传感器
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for CJ/T 347-2010 in 30 minutes.
Issued by
Ministry of Housing and Urban-Rural Development of the People's Republic of China
Level / Type
National · Recommended
Issue date
August 3, 2010
Implementation date
January 1, 2011
Scope
CJ/T 347-2010 is the English-translated version of 家用燃气报警器及传感器.
CJ/T 347-2010 — This standard specifies the domestic gas alarm and sensor requirements, test methods, inspection rules, signs, packaging, transportation and storage.
This standard applies to the detection of gas leaks and detection of incomplete combustion of gas produced by carbon monoxide home gas alarm and sensor.
Found what you need?
Document preview — CJ/T 347-2010
National Standard of the People's Republic of China
- ICS
- 91.140.99
- Classification
- P 47
- Replacing
- CJ/T 3057-1996
Issued by: Ministry of Housing and Urban-Rural Development of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Alarm
- 4.1 Model
- 4.2 Requirements
- 4.3 Test Method
- 5 Sensor
- 5.1 Requirements
- 5.2 Test Methods
- 6 Inspection rules
- 6.1 Alarm factory inspection
- 6.2 Alarm type test
- 6.3 Sensor type test
- 7 Marking, Packaging, Transport and Storage
- 7.1 Alarm sign, package, transport and storage
- 7.2 Sensor marking, packaging, transport and storage
- Appendix A (Normative) sample test items and alarm number correspondence table
- Appendix B (Normative) sample test items and sensor number correspondence table
- References
Foreword
This standard replaces CJ 3057-1996 "household gas leak alarm." this standard is the revision of CJ 3057-1996, compared with the standard CJ 3057-1996, the main technical changes are as follows.
--- Increase the incomplete combustion alarm and composite alarm requirements;
--- Increasing the radiation electromagnetic field, electrostatic discharge, electrical transient pulse test;
--- Increased anti-gas interference performance;
--- Increased gas resistance;
--- Increased anti-silicon poisoning performance.
--- Increased high concentration of durability;
--- Increased with silencer function silencer function test;
--- Increased use of the battery alarm low voltage performance test;
--- Modify the shell flame retardant;
--- Modify the response time;
--- Modify the power supply voltage fluctuation test;
--- Modify the resistance to environmental performance;
--- Modify the long-term stability test;
--- Modify the short-term stability test;
--- Modify the vibration and drop test;
--- Remove the circuit board clearance test.
This standard Appendix A and Appendix B are normative appendix.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban-township gas standard technical focal points centralized.
This standard was drafted. North China Municipal Engineering Design and Research Institute, Tianjin Figaro Electronics Co., Ltd., Tianjin Puhai new technology Co., Ltd., Qingdao Economic and Technological Development Zone Haier Water Heater Co., Ltd., Nanjing AO Smith (China) Water Heater Co., Ltd. Sakura Kitchen (China) Co., Ltd., Midea Group Co., Ltd., Zhuzhou South Valve Co., Ltd.
1 Scope
This standard specifies the domestic gas alarm and sensor requirements, test methods, inspection rules, signs, packaging, transportation and storage.
This standard applies to the detection of gas leaks and detection of incomplete combustion of gas produced by carbon monoxide home gas alarm and sensor.
2 Normative references
The terms in the following documents become the subject of this standard by reference to this standard. For dated references, all subsequent ones Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to reach an agreement in accordance with this standard research is no The latest versions of these files are available. For undated references, the latest version applies to this standard.
Casting copper alloys - Technical conditions GB/T 1176-1987 Plastics - Determination of combustion behavior by oxygen index method - Part 2. Room temperature test GB/T 2828.1 Sampling procedures for inspection - Part 1. Batch inspection sampling plan by acceptance quality limit (AQL) (GB/T 2828.1-2003, ISO 2859-1.:1999, IDT) GB 15322.2-2003 combustible gas detectors Part 2. Measuring range of 0 ~ 100% LEL independent flammable gas exploration Detector
3 Terms and definitions
The following terms and definitions apply to this standard.
Combination alarm with gas leak alarm, at the same time with incomplete combustion alarm gas alarm function.
Sensor detection module sensortestmodule Used to convert sensor characteristics into a test device with a binary output signal.
4 Alarm
4.1 Models
4.1.1 Code
a) Gas category code. R-Artificial gas, Y-LPG, T-natural gas, C-incomplete combustion.
b) Output signal type code. K-switch output, V-voltage output, F-pulse output, T-other.
4.1.2 Model preparation
Alarm (B)
Gas category code
Output signal type code (Pinyin letters) Factory Design Serial Number (Arabic letters)
4.1.3 Example
Example 1. "BTC-K1" means natural gas and incomplete combustion compound alarm with output switch, first design and finalization.
Example 2. "BY-V1" said liquefied petroleum gas alarm, with voltage output, the first design stereotypes.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1176-1987Casting copper and copper alloys
- GB/T 2828.1Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 2828.1-2003Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB 15322.2-2003Combustible gas detectors - Part 2: Household combustible gas detectors
ISO 2859
How to Download CJ/T 347-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2828.1-2012 — Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
GB/T 2828.10-2010 — Sampling procedures for inspection by attributes -- Part 10: Introduction to the GB/T 2828 series of standards for sampling for inspection by attributes
GB/T 2828.11-2008 — Sampling procedures for inspection by attributes Part 11: Procedures for assessment of declared quality levels for small population
Secure payment via Stripe
Payments accepted
CJ/T 347-2010
$355.00