CJ/T 312-2009Measurement of noise from building water drainage piping system (English PDF)
建筑排水管道系统噪声测试方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for CJ/T 312-2009 in 30 minutes.
Issued by
Ministry of Housing and Urban-Rural Development of the People's Republic of China
Level / Type
National · Recommended
Issue date
May 18, 2009
Implementation date
December 1, 2009
Scope
CJ/T 312-2009 is the English-translated version of 建筑排水管道系统噪声测试方法.
CJ/T 312-2009 — This standard specifies the terms and definitions of noise measurements generated by the building drainage piping system under laboratory conditions, symbols, experimental principles, Experimental equipment, laboratory facilities, samples, experiments, laboratory reports.
This standard applies to building drainage pipe system noise test. Test results can be used for the construction of drainage pipe system related products and materials between the comparison can also be used under certain conditions, building drainage Estimation of noise characteristics of channel system.
Found what you need?
Document preview — CJ/T 312-2009
National Standard of the People's Republic of China
- ICS
- 13.020
- Classification
- P 41
Issued by: Ministry of Housing and Urban-Rural Development of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbol
- 5 Experimental principle
- 6 Experimental equipment
- Experimental facilities
- 8 Sample
- Experiment
- 10 Experimental Report
- Appendix A (Normative) Wall structure sensitivity measurement
- Appendix B (informative) Calibrated Experimental Wall Reciprocal Law
- Appendix C (informative) test report standard format
Foreword
This standard is modified using EN14366.:2004 "laboratory measurement of wastewater noise" (Laboratorymeasurementofnoise fromwastewaterinstalations). The main technical differences from EN14366.:2004 are as follows.
--- According to the Chinese habit of some layout format has been modified;
--- Increasing the drainage pipe system terms and definitions;
--- Remove the rain down the pipe test application;
--- Increasing the number of test microphone position, the choice of requirements, while increasing the average sound pressure level terms, definitions and algorithms formula;
--- Modify the distance between the bottom elbow and the floor to suit China's national conditions;
--- Modify the test laboratory floor, while increasing the number of laboratories in order to achieve the same time test the drainage of adjacent two layers the influence of noise
--- Increasing the application of the test method for the noise generated by the drainage pipe system containing sanitary appliances;
--- Increased inspection report reference format.
Appendix A of this standard is a normative appendix, Appendix B and Appendix C are informative appendices.
This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.
This standard by the Ministry of Housing and Urban Water Supply and Drainage Products Standardization Technical Committee.
1 Scope
This standard specifies the terms and definitions of noise measurements generated by the building drainage piping system under laboratory conditions, symbols, experimental principles, Experimental equipment, laboratory facilities, samples, experiments, laboratory reports.
This standard applies to building drainage pipe system noise test.
Test results can be used for the construction of drainage pipe system related products and materials between the comparison can also be used under certain conditions, building drainage Estimation of noise characteristics of channel system.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. All dated references, which are subsequently owned Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to reach an agreement based on this standard research Whether you can use the latest versions of these files. For undated references, the latest version applies to this standard.
GB/T 4129 Acoustics Standard sound source performance and calibration requirements for sound power level determination GB/T 14412 mechanical vibration and impact accelerometer mechanical installation GB/T 19889.3-2005 Acoustics - Measurement of sound insulation in buildings and of building elements - Part 3. Experimental study of airborne sound insulation of building elements Room measurement GB/T 20247 acoustic reverberation room sound absorption measurement GB/T 20485.21 vibration and shock sensor calibration method - Part 21. Vibration comparison method calibration
3 Terms and definitions
The following terms and definitions apply to this standard.
For the discharge of daily sewage and wastewater pipes, fittings, all fixed components and sanitary appliances consisting of a system of general.
Experimental Object Combination System for Noise Testing.
Laboratory for the installation of noisy test samples and for measuring the airborne sound generated by the samples.
It is not intended to be used in laboratories that emit noise samples but measure the structure of the samples.
Specified sample format for benchmarking.
Specified installation conditions for standard configuration.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4129Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels
- GB/T 14412Mechanical vibration and shock -- Mechanical mounting of accelerometers
- GB/T 19889.3-2005Acoustics - Field measurement of sound insulation in buildings and of building elements - Part 3: Airborne sound insulation of facade elements and facades
- GB/T 20247Acoustics -- Measurement of sound absorption in a reverberation room
- GB/T 20485.21Methods for the calibration of vibration and shock transducers -- Part 21: Vibration calibration by comparison to a reference transducer
How to Download CJ/T 312-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14412-2005 — Mechanical vibration and shock -- Mechanical mounting of accelerometers
GB/T 20247-2006 — Acoustics -- Measurement of sound absorption in a reverberation room
GB/T 20485.21-2007 — Methods for the calibration of vibration and shock transducers -- Part 21: Vibration calibration by comparison to a reference transducer
Secure payment via Stripe